en | 10 | SCT 418
5.4.3
Attaching "calibration boards without retain‐
ing plate"
 2x retaining adapter X
 Calibration board retainer T
1. Push the left and right slides all the way out.
2. Hook 2x retaining adapters X into the retaining
brackets on the indicator bar.
2x
3.
2.
1.
3. Secure the left and right retaining adapter X hand-
tight with knurled screws.
4. Position calibration board retainer T all the way up.
5.
5. Place the calibration board in the retaining adapters
X so that the two arrows on the calibration board are
aligned exactly with the retaining adapters X.
1 689 989 518 | 2022-07-24
4.
1.
6.
6. Push calibration board retainer T onto the top edge
of the calibration board in such a way that the re‐
cess in calibration board retainer secures the cali‐
bration board.
7. Use the knurled screw to hand-tighten calibration
board retainer T.
 The calibration board is now secured and fixed in
place.
When not using the retaining adapters X, we rec‐
ommend turning the retaining adapters X 180° to
the rear and securing them hand-tight in this park
position with knurled screws.
---
5.5
Calibrating with the SCT 418
1. Start the diagnostic software.
2. Perform calibration.
3. Follow the instructions in the software.
---
5.6
Following calibration
1. Remove the calibration boards.
2. Release the locking device of the indicator bar and
lower the indicator bar so that no head injuries can
occur.
The indicator bar can be damaged if the SCT 418
is pulled or pushed by the indicator bar.
3. If the SCT 418 is not used for an extended period,
10 "Moving the indicator bar to parking
4. Use the alignment frame to move the SCT 418 to the
desired storage location.
---
5.7
Moving the indicator bar to parking
position
1. Disconnect the USB connecting cable.
2. Removing the mount for large calibration boards
3.
4.
3. Remove the clamping screws (E).
 When repositioning the indicator bar, make sure that
no bystanders are injured or nearby objects dam‐
aged.
The indicator bar or the measuring technology in‐
stalled in it can be damaged if the indicator is set
down roughly or dropped.
4. Lift the indicator bar off the alignment unit.
position".
3.
4.