EIB 749: remote reset
Remote-Reset
2-pin connection
The input signals (Remote-
Reset +, Remote-Reset –) are
galvanically isolated from the
ground potential at the encoder
and trigger connections
Input voltage
U
Reset,In
range
Remote-Reset + measured
against Remote-Reset –:
Min. –0.5 V, max. +14.0 V
U
Reset,In,Lo
Reset = 0: Min. –0.5 V,
max. +0.8 V
U
Reset,In,Hi
Reset = 1: Min. +2.0 V,
max. +14.0 V
Current
I
: 10.0 mA
Reset
consumption
Ambient conditions
Operating
0 °C to 45 °C, no condensation
temperature
Storage
–20 °C to 70 °C, no condensation
temperature
General information
Directives
EMC Directive 2014/30/EU
Low Voltage Directive 2014/35/EU
Pollution degree
2
Protection
IP 20
EN 60529
Dimensions
See dimension drawings in Page 135 ff. in the
Appendix.
All dimensions are in millimeters [mm].
34