01/2006
[DriveTextFiles]
ALDEV_80E5=f:\dh\mb.dir\aldvs_
ALDRV_80E5=f:\dh\mb.dir\aldrs_
;ALDEV_808F=f:\dh\mb.dir\aldvu_
;ALDRV_808F=f:\dh\mb.dir\aldru_
ALDEV_x=f:\dh\mb.dir\aldvp_
ALDRV_x=f:\dh\mb.dir\aldrp_
[IndexTextFiles]
ALNX=f:\dh\mb.dir\alnx_
ALSI=f:\dh\mb.dir\alsi_
[DEFAULTPRIO]
CANCEL=100
RESET=100
POWERON=100
NCSTART=100
PLC=100
PLCMSG=100
MMC=100
[PROTOCOL]
Filtro=expresión
Records=150
DiskCare=−1
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D sl/840Di sl/840D/810D Puesta en servicio HMI (IAM) – Edición 01/2006
; drive and device type specific alarm text files
; default definition of the priorities of the different alarm types
; This section defines different characteristics of the protocol that
; specifies how particular error messages are to be registered.
Detalles sobre la formación de expresiones de filtro para el control del
volumen de avisos se encuentran en el apartado 2.4.2 Ajustar el protocolo
de alarmas.
; Criteria for selecting the alarm messages to be recorded. The notation
; is described in SINUMERIK 840D OEM package HMI User's Manual.
; Characterizes the numbers of entries in the log file. If the actual
; number exceeds this value, the server starts to override old entries
; (principle: ring buffer)
; Mode of alarm protocol writing
; if a number of less than -1 is specified, this number of protocol files is
; parallely held, and one of them is actually used
; if a number of -1 is specified, the protocol-file is not automatically updated
; if 0 is specified the protocol file is immediately updated
; if a number above 0 is specified, the protocol file is updated after the
; specified number of seconds elapsed with no intermediate alarm state
; changes. t he protocol-file is always updated when you send the
; DDE-Command: "AlarmProt" to the MBDDE-server
; (principle: ring buffer) ---------------------------------------------------------------
# attention: the mode changed from V4 to V5 !
Puesta en servicio HMI-Advanced (IM4)
2 Ajustar funciones y parámetros
IM4/2-97