Pride Mobility FUSION e Manual Del Propietário página 30

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

DO NOT ATTEMPT TO OPEN ANY PARTS OF THE POWER CHAIR
CONTROL SYSTEM, BATTERY PACK, LOOMS, PLUGS OR BATTERY
THE CONTROL SYSTEM IS SAFETY CRITICAL AND THERE ARE NO USER
Your power chair is fitted with a self-diagnostic controller that will give a sequence of
audible beeps when an error is detected to help you, or the authorized service agent,
determine the drive electronics fault. Should you switch on the power chair and hear the
beeps note the number of beeps, separated by a short delay between each sequence,
and refer to the table below.
NUMBER
OF
REPRESENTS
BEEPS
1
Battery power low
Low battery
2
voltage
High battery
3
voltage
Electric current
4
over limit
Freewheel level
5
Accelerate the
6
variable resistor
Fusione
CHARGER.
SERVICEABLE PARTS
POSSIBLE
Power not enough
Power not enough
Too high voltage,
while overloading
or climbing
Electric current
over limit of motor
The freewheel
issue
level is on
When turning on
the controller,
accelerate variable
resistor isn't in the
issue
neutral position
CAUSE
Decrease speed while
Check battery connection
Check motor and relative
wiring connections.
Switch off and wait a few
minutes and switch on.
Check the relative wiring
of the freewheel level.
Confirm the level is on
the correct position
Accelerate variable
resistor may be in neutral
Accelerate variable
resistor may need to
SOLUTION
The battery needs
charging
The battery needs
charging
climbing
position
recalibration.
- 29 -
Tabla de contenido
loading

Tabla de contenido