2.4 - ELECTRICAL CONNECTION
The appliance is fitted with a power cable with plug.
Before connecting the air conditioner ensure that:
• The voltage and power frequency values match those specified on the
appliance plate data.
• The power line is equipped with an effective earth connection and is
correctly sized for maximum power consumption of the air conditioner.
• The appliance's power network must be equipped with a suitable
omnipolar disconnection device compliant with national installation
regulations.
• The appliance is powered solely through a socket compatible with the plug provided.
CAUTION
Any replacement of the power cable must be carried out solely by Olimpia Splendid
technical support or by similarly qualified personnel.
2.5 - DRAINAGE
Depending on the mode of operation of the appliance, it is necessary to connect the condensation drainage
hose. For use as dehumidifier or heat pump (only for suitable models) work as follows (Fig.12-13a-13b):
a. Unscrew the cap (28) or the cap (35) for models with heat pump.
b. Remove the rubber cap (32).
c. Insert the pipe (7) in the connector.
Make sure the end of the discharge pipe (7) is positioned on a drain well or in a container.
Make sure the pipe (7) is not clogged.
3 - USE OF THE APPLIANCE
The functioning modes if the air conditioner can be selected both through the remote control and through the
control panel located on board of the air conditioner.
The reception of the selected function is confirmed by the emission of a "beep" by the buzzer.
3.1 - REMOTE CONTROL KEYS
• B1: ON/OFF key;
• B2: "Timer" key;
• B3: "Sleep" key;
• B4: Temperature increase/delay key;
• B5: Temperature decrease/delay key;
• B6: "Fan";
• B7: "Mode" key
cooling =˃
=˃ dehumidification =˃
=˃ fan only =˃
=˃ heating (active only in the version with
heat pump)=˃
=˃ cooling =˃ ...
• B8: "Swing" key
(Fig.C)
C
B6
B3
B5
B8
B4
B7
B2
B1
EN - 13