Idiomas disponibles

Idiomas disponibles

3.
Drill holes in the surface for the anchors. Install anchors.
4.
Line-up holes in surface with holes in air compressor feet.
5.
Place the vibration pads (not supplied) between the floor
and air compressor feet, see Fig 15. If needed, use shims to
level the unit.
6.
Place the 3/8" lag screws through the air compressor feet,
vibration pads and into the anchors.
7.
Torque 3/8" lag screws to 7-10 ft.-lbs (9.5-13.5 Nm).
Vibration Pad (not supplied) Diagram
3/8" Lag Screw
M
(not supplied)
N
Tank Leg
Vibration Pad
O
(not supplied)
P
Surface Line
Concrete Anchor
Q
(not supplied)

ELECTRICAL WIRING

WARNING: Improper electrical installation of this product may void its
warranty and your fire insurance. Have circuit wiring performed by
qualified personnel such as a licensed electrician who is familiar with
the national electrical code and any prevailing local electrical codes.
Fig. 15
M
N
O
Q
P
WARNING: Risk of electrical shock. Improper electrical grounding can
result in electrical shock. The wiring should be done by a qualified
electrician.
A qualified electrician needs to know the following before wiring:
1.
The amperage rating of the electrical box is adequate. Refer
to the Specifications, page 8, for this information.
2.
The supply line has the same electrical characteristics
(voltage, cycle, phase) as the motor. Refer to the motor
nameplate for this information.
NOTICE: The wiring used must be rated for the motor nameplate
voltage, plus or minus 10%. Refer to local codes for
recommended wire sizes, correct wire size and maximum wire
run. Undersized wire causes high amp draw and overheating to
the motor.
NOTICE: A circuit breaker is recommended. If the air
compressor is connected to a circuit protected by a fuse, use
only time delay fuses.
WARNING: Risk of electrical shock. Electrical wiring must be located
away from hot surfaces such as manifold assembly, air compressor outlet
tubes, heads or cylinders.

GROUNDING INSTRUCTIONS

WARNING: Risk of electrical shock. In the event of a short circuit,
grounding reduces the risk of shock by providing an escape wire for the
electric current. This air compressor must be properly grounded.
13