TROUBLESHOOTING POSSIBLE PROBLEMS IN OPERATION

CONDITION
Heavy top or
bottom
pattern
Heavy right or
left side
pattern
Remedies for the top-heavy, bottom-heavy, right-heavy, and left-heavy patterns:
1. Determine if the obstruction is on the air cap or the fluid tip. Do this by making a test
spray pattern. Then, rotate the cap one-half turn and spray another pattern. If the defect is
inverted, obstruction is on the air cap. Clean the air cap as previously instructed. Also check
for dried paint just inside the cap centre hole opening; remove by washing with solvent.
2. If the defect is not inverted, it is on the fluid tip. Clean tip. If problem persists, renew tip.
Heavy centre
pattern
Split spray
pattern
All manuals and user guides at all-guides.com
CAUSE
Horn holes plugged.
Obstruction on top or
bottom of fluid tip.
Cap and/or fluid tip
seat dirty.
Left or right side
horn holes plugged.
Dirt on left or right
side of fluid tip.
Pattern adjustment
valve set too low.
Atomising pressure
too low.
Material too thick.
Air pressure too high.
Fluid adjusting knob
turned in too far.
Pattern adjusting
valve set too high.
Page 12 of 16
CORRECTION
Clean. Ream with non-metallic
point.
Clean.
Clean.
Clean. Ream with non-metallic
point.
Clean.
Turn out counter clockwise to
achieve correct pattern.
Increase pressure.
Thin to correct consistency.
Reduce at regulator or gun handle.
Turn out counter clockwise to
achieve correct pattern.
Turn in clockwise to achieve correct
pattern.