TECNOMOTOR TM 514 Manual De Instrucoes página 84

Ocultar thumbs Ver también para TM 514:
Tabla de contenido
TM 514 – COMMON RAIL TEST
Produzido por Tecnomotor Eletrônica do Brasil S/A - REPRODUÇÃO PROIBIDA - Eventuais erros ou defeitos favor comunicar [email protected]
Injector flow test
To date, the TM 514 has performed electrical and tightness testing. If the injector
passes these tests, the TM 514 will proceed with the flow test automatically as
shown in the figure below.
The injector actuation test, after the tightness test and electrical test, always
starts by heating the injector. This is because the injector working temperature
influences its flow.
However, if the operator wishes, they may choose not to warm up the injector
before the flow test, at the risk of erroneous results. To do this simply uncheck
the "WARMING" option before starting the tests, as shown in the next figure.
178
Tabla de contenido
loading

Tabla de contenido