TM 514 – COMMON RAIL TEST
Produzido por Tecnomotor Eletrônica do Brasil S/A - REPRODUÇÃO PROIBIDA - Eventuais erros ou defeitos favor comunicar
[email protected]
Keep the oil outlet connection half-open so that air from the system is exhausted.
Open connection with a hose to direct fluid.
At the "Remote Configuration" screen, press the "Fluid Maintenance" button.
Then press the "Circular Fluid" button. At this time oil should be discharged from
the high pressure outlet. The operation should be performed until there is no
more air residue in the system.
For this action, the tank should be fluid and the cap must be closed.
If the fluid is below the level, put more fluid and restart the process to circulate the
fluid.
If the cover is opened, the pump will stop.
To restart, close the cover and push the button to begin the process.
167