Produzido por Tecnomotor Eletrônica do Brasil S/A - REPRODUÇÃO PROIBIDA - Eventuais erros ou defeitos favor comunicar
[email protected]
Error
166
Code
Probable Cause
- CPRC parameterizes SOM board with center
of mass greater than 105mm.
Error
167
Code
Probable Cause
- CPRC parameterizes SOM board with center
of mass greater than 105mm.
Error
168
Code
Probable Cause
- CPRC parameters SOM board to measure
injection and return simultaneously.
Error
171
Code
Probable Cause
- Over the limit of hour usage.
Error
172
Code
Probable Cause
- Test fluid usage hour counter is at the limit.
Error
173
Code
Probable Cause
- No injector connected to the system.
- Bad contact with injector(s) terminals.
- Injector(s) with short circuit, open or outside
working range. Injectors with electrical damage
will not be mechanically tested.
- Damage to the control board drivers.
Error
174
Code
Probable Cause
- Error recording memory.
TM 514 – COMMON RAIL TEST
Parameterization error - center of mass CH1
- Contact the manufacturer.
Parameterization error - center of mass CH2
- Contact the manufacturer.
Parameterization error - Simultaneous measurement
- Contact the manufacturer.
Replace and reset hour counter.
- Replace fluid filter by following Tecnomotor
specifications.
- Contact Technical Assistance to perform the
complete periodic maintenance.
Replace and reset hour counter.
- Replace test fluid by following Tecnomotor
specifications - Calibration fluid ISO4113.
- Contact Technical Assistance to perform the
complete periodic maintenance.
Injector(s) not found.
Connect an injector.
- Connect another injector of the same actuator
type (inductive or piezoelectric) to test the
channel.
- Check connections and the condition of the
injector(s).
- Check the condition of the power adapter for
discontinuity.
FLASH recording error.
Possibility of losing data.
- Call technical assistance.
208
Solution
Solution
Solution
Old filter.
Solution
Old oil.
Solution
Solution
Solution