Range Of Use - T.I.P. HWA 6000 EPF Traducción De Las Instrucciones De Uso Originales

Ocultar thumbs Ver también para HWA 6000 EPF:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Model
Min. flow rate
Max. pressure
Max. delivery height (Hmax)
Max. suction height
Max. self priming height
Max. size of the solids being pumped
Max. permissible operating pressure
Min. ambient temperature
Min. fluid temperature
Max. fluid temperature (Tmax)
Max. cut-in frequency in one hour
Length of connection cable
Cable type
Weight (net)
Guaranteed sound power level (LWA) 2)
Measured sound power level (LWA) 2)
Sound pressure level (LpA) 2)
Dimensions (L x D x H)
Article no.
1)
The values were determined with free, unreduced in- an outlet.
2)
Noise emission values obtained according to the EN 12639 regulation. Measurement method ac-
cording to EN ISO 3744.

3. Range of use

Automatic booster sets from T.I.P. are portable self-priming electrical pumps with
an electronic pump control system for automated operation. These high-quality
products with their convincing performance data were developed for the various
purposes involved with irrigation, water withdrawal, domestic water supply and
water discharge as well as for the further conveyance of water under pressure.
These units are suitable for pumping clean, clear water or moderately dirty water
containing solids up to the max. size as indicated in the technical specification.
The typical areas of use of automatic booster sets include: Automated domestic
water supply with grey water from wells and cisterns; automated irrigation of gar-
dens and garden beds as well as sprinkling applications; filling or emptying of
storage reservoirs, pools and ponds.
The device is not suitable for use in swimming pools or for installation in public
water mains.
This product is intended for private use in the home area and not for commercial
or industrial purposes or for continuous circulating.
The pump is not suited to discharge saltwater, faeces, inflammable,
etching, explosive or other hazardous liquids. Please observe the max.
and min. temperatures of the liquids to be discharged stated in the
technical data.
20
1)
Translation of the Original Operating Instructions
HWA 6000 EPF
250 l/h
4.5 bar
45 m
9 m
7 m
3 mm
6 bar
5 °C
2 °C
35 °C
40, evenly distributed
1.5 m
H07RN-F
ca. 13.2 kg
82 dB (A)
80.6 dB (A)
67.9 dB (A)
48.5 x 24.5 x 29.0 cm
30198
3
Tabla de contenido
loading

Este manual también es adecuado para:

30198

Tabla de contenido