Any nonobservance of this instruction bears the risk of an electrical shock which may
cause damage to persons or property.
Please inspect the device for damage occurred during transportation. In case of damage, the retailer
has to be informed immediately, at the latest within 8 days after the date of purchase.
2. Technical Data
Model
Mains voltage / frequency
Nominal performance
Protection type
Pressure port
1)
Max. flow rate (Q
)
max
Max. pressure
1)
Max. delivery height (H
)
max
Max. submersion depth
Max. size of the solids being pumped
Max. fluid temperature normal use (T
Max. fluid temperature short termed (T
Max. cut-in frequency in one hour
Length of connection cable
Cable type
Weight (net)
2)
Min. self-priming level (A)
2)
Min. suction level (B)
2)
Cut-in level (C)
2)
Cut-out level (D)
Dimensions (L x D x H)
Item no.
1)
The values were determined with free, unreduced outlet.
2)
The values between brackets refer to the illustrations given at the end of these operating instructions.
3)
When water temperature exceed 50 °C, but not exceed 95 °C, it only operates 4 min, then stop until the
motor completely cool down.
3. Range of use
Submersible dirty water pumps from T.I.P. are highly efficient electrical pumps for discharging clear or
dirty water containing solids up to the maximum size specified in the technical details. These high-
quality products with their convincing performance data were developed for the multiple purposes
involved with draining and pumping liquids from one place to another.
Typical applications for waste water submersible pumps are: Emptying ponds, tanks, storage tanks,
and waste water pits, as well as emergency drainage in the event of flood or high water.
Submersible dirty water pumps from T.I.P. are suitable for stationary or temporary installations.
This product is intended for private use in the home area and not for commercial or industrial purposes
or for continuous circulating.
The device is not suitable for use in swimming pools or for installation in public water mains.
The pump is not suitable for use in table-top fountains, aquariums or similar ranges of use.
When using the unit in a pond, please take the required action to ensure that no inhabitants of the
pond will be sucked in.
The pump is not suited to discharge saltwater, faeces, inflammable, etching,
explosive or other hazardous liquids. Please observe the max. temperature of the
liquids to be discharged stated in the technical data. The short-term operation (max.
4 min.) period with a liquid temperature of up to 95°C is a special feature of this
pump.
)
max
3)
≤ 4 min)
max
2
EXTREMA 500/13 PRO
230 V~ 50 Hz
1,800 Watt
IP 68
59.61mm (2" male)
30,000 l/h
1.3 bar
13 m
7 m
45 mm
50 °C
95 °C (max. 4 min.)
30, evenly distributed
10 m
H07RN8-F
~ 13 kg
125 mm
65 mm
570 - 470 mm
180 -320 mm
24,5 x 23,5 x 45 cm
30171
9