Name of
Accessories
Optional
part (one
Transfer connector
piece/ one
(packed with the indoor or
outdoor unit, depending on
models)
NOTE: Pipe size may differ
Optional
from appliance to appliance.
part (1-5
To meet different pipe size
pieces for
requirements, sometimes
the pipe connections need
a transfer connector installed
depending
on the outdoor unit.
on mod-
Drain joint (some models)
Seal ring (some models)
OPTIONAL
Name
Connecting pipe assembly.
7 - INSTALLATION
7.1 - PROCEDURES FOR INSTALLATION
• Install the outdoor unit
MC
• Evacuate the refrigeration system
Q'ty
Shape
(pc)
indoor
unit)
outdoor
unit,
els)
1
1
Liquid side
Gas side
• Connect the refrigerant pipes
MC
Name of
Accessories
Magnetic ring (Hitch it on the
connective cable between
indoor unit and outdoor unit
after installation.)
(some models)
Cord protection rubber
ring
(If the cord clamp cannot fas-
ten on a small cord, use the
cord protection rubber ring
[supplied with accessories]
to wrap around the cord.
Then fix it in place with the
cord clamp.)
(some models)
Forma
Ø6.35 (1/4 in)
Ø9,52 (3/8 in)
Ø9,52 (3/8 in)
Ø12.7 (1/2 in)
Ø 16 (5/8 in)
• Perform a test run
Q'ty
Shape
(pc)
Varies
by model
1
Quantità (PC)
Parts you must purchase separate.
L
N
(L1)
(L2)
• Connect the wires
EN - 13
ARYAL S2 E DUAL / TRIAL