Setting Force Valve Spring Selection; Tool Operation - Stanley PNT1000L-PC Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 89
E N G L I S H

Setting Force Valve Spring Selection

There is one type of spring used with the PNT1000L-PC tool that covers the range of inserts indicated.
Review the table below Valve Spring part number.
Table 6: Setting Force Valve Spring for Standard & Thick Wall inserts
Thread Size
M6
1/4-20
M8
5/16-18
Thick Wall
(Std & ST)
M10
3/8-16
M12
1/2-13
* Need to set tool at 0.55Mpa Minimum.
Table 7: Setting Force Valve Spring for Thin Wall inserts (TK, TL, TH)
Thread Size
M6
1/4-20
M8
5/16-18
Thin Wall
(TK,TL, TH)
M10
3/8-16
M12
1/2-13

Tool Operation

Loading the POP NUT™ onto the tool
1.
Connect the air supply to the tool.
2.
Thread the insert 1/4 turn onto the Mandrel.
3.
Press the insert against the Mandrel as indicated and the Mandrel will spin, automatically threading the insert onto the
Mandrel.
4.
Keep pushing the insert onto the Mandrel until the Mandrel stops spinning (If the insert is not fully threaded, the
setting stroke will be shortened by the gap between the head of the insert and the Nosepiece).
18
Material
Aluminum
Steel
-
DPN901-023
DPN901-023
DPN901-023
DPN901-023
DPN901-023
-
DPN901-023
Steel
DPN901-023
DPN901-023
DPN901-023
DPN901-023
DPN901-023:
Figure 8: Valve Spring
RLT
DPN901-023
DPN901-023
-
-
20 mm
[0.79 in]
Stainless
DPN901-023
DPN901-023
DPN901-023*
-