Chargeable lamp (optional)
As soon as the door has reached the open position, the
chargeable lamp connected to X6 is switched on. As soon as the
door leaves the open position, the chargeable lamp switches off
again.
Safety wheel chock (optional)
Only if the wheel chock is positioned behind the truck tyre, the
loading bridge can be lifted and extend the support.
In case of a wheel chock being provided for safety reasons,
the
and
buttons will only be active if the wheel chock is po-
sitioned at the truck. After the loading bridge is positioned on the
vehicle, the RETURN button can be actuated once, even if the
safety chock has been removed.
Loading bridge status display
Display State
Control ready to operate
Loading bridge moves back to resting position
Loading bridge is lifted
Loading bridge is lowered
Support is extended
Support is retracted
Loading bridge in stop or resting position
Loading bridge in floating position
Symbol flashing: Restart lock active
Symbol permanently illuminated: Safety circuit active
Have service carried out by a technician
Functional description for the door operation
During operation, note that a green status LED (left
above each button) signalises whether the desired function is cur-
rently enabled for operation.
The control allows for the selection of different operating modes:
Dead man OPEN / dead man CLOSE
By pressing the
door operation starts in the OPEN direction until the OPEN door
end position has been reached or the door operation is stopped
by letting go of the button. The door is closed by continuously
pressing the button (dead man function) until the door end po-
sition has been reached. If you let go of the
door is closing, the door will stop immediately.
Pulse OPEN / dead man CLOSE
By briefly pressing the
the door starts moving in the OPEN direction until the door end
position OPEN has been reached or the door operation is
stopped by pressing the
continues the opening operation. The door is closed by continu-
ously pressing the
end position CLOSE has been reached. If you let go of the
button while the door is closing, the door will stop immediately.
Pulse OPEN / pulse CLOSE
By briefly pressing the
the door starts moving in the OPEN direction until the door end
position OPEN has been reached or the door operation is
stopped by pressing the
ton, the door starts moving in the CLOSE direction until the door
end position CLOSE is reached.
This operating mode requires the installation of a closing edge
safety device (menu item 35). When the closing edge safety
device is activated while the door is closing, the door will stop and
a direction reversal will take place. Activation of the safety device
has no effect when the door is opening. If there is a defect, the
door can be closed by the button.
EMERGENCY operation
Risk of being crushed or hit by the moving
WARNING
door in EMERGENCY operation
Persons can be struck when the door is closed
or collide with the door.
•
•
EMERGENCY operation permits the operation of the door with
defective or tripped safety devices.
EMERGENCY operation is activated after 5 seconds of perman-
ent actuation of "OPEN" or "CLOSE" whilst E06 or E07 is dis-
played and is indicated by an F30 message on the display.
Lighting and / or an advance warning light (optional)
The control is provided with two relay outputs by means of which
the dock light and / or the red/green traffic light is switched (menu
items 45 and 46).
TAD MS 400V / 230V
button continuously (dead man function), the
button or by external pulse generators,
button. Pressing the
button (dead man function) until the door
button or by external pulse generators,
button. By briefly pressing the
For EMERGENCY operation the door
needs to be checked and found to be in per-
fect condition.
While the "Dead man" operating mode is
active, a clear view to the door from the
place of operation must be ensured.
button while the
button again
but-