Menu 5 Various settings
Menu
Entry
Selection
item
50
Key switch function (J7)
0
Pulse input OPEN/CLOSE (default setting)
1
Inhibit control panel
2
Inhibit external control elements
3
Inhibit control panel and external control ele-
ments
4
Activate control elements for 10 seconds
5
Switch-over to dead man mode for closing
6
Pulse input OPEN-STOP-CLOSE
7
Pulse input for smoke and heat extraction sys-
tem (setting in menu item 55)
8
Activate control elements for 300 seconds
9
Input for electrical interlocking EDL100
10
Inhibit loading bridge
51
Function of external command transmitter (J1)
0
Three-button-control (default setting)
1
OPEN-STOP-CLOSE function (J1.3, J1.4 full
opening)
52
001-256 Entry of control address
53
Door control module and inflatable door sealing
0
off (default setting)
1, 2, 3 For control profiles see control door module
4
DC module
5
RadioBand module, wireless closing edge
(optional)
6
reserved
54
Extended control
0
Off (default setting)
1, 2, 3 For control profiles see extended control
55
Door setting for smoke and heat extraction
system position
59
9
Do not change control variant!
- -
Exit menu
Menu 6 Radio
Menu
Entry
Selection
item
60
Programming the start button on the hand-held
transmitter
62
Programming the light button on the hand-held
transmitter
63
Deleting radio codes
Press for 5 s
- -
Exit menu
Menu 7 FU and DU settings
Menu
Entry
Selection
item
71
Opening speed
20 - 65 Speed in revolutions / min.
30
Factory settings
72
Closing speed
20 - 30 Speed in revolutions / min.
20
Factory settings
Menu 7 FU and DU settings
Menu
Entry
item
73
Increased closing speed
20 - 30 Speed in revolutions / min.
20
74
Door setting change-over point [73] to [72]
75
Acceleration time open
10 - 30 x 0.1 s
20
76
Acceleration time close
10 - 30 x 0.1 s
20
77
Braking time open
10 - 30 x 0.1 s
20
78
Braking time close
10 - 30 x 0.1 s
20
- -
Menu 9 Service menu
menu
Entry
item
90
Selection of the door maintenance cycle
0
1
2
3
4
5
6
7
8
9
10
11
12
91
Cycle counter output door cycles
92
Selection of the loading bridge maintenance cycle
0
1
2
3
4
5
6
7
8
9
10
11
93
Cycle counter outputloading bridge cycles
TAD MS 400V / 230V
Selection
Factory settings
Factory settings
Factory settings
Factory settings
Factory settings
Exit menu
Selection
No service interval (default setting)
1000 cycles
4000 cycles
8000 cycles
12000 cycles
16000 cycles
20000 cycles
25000 cycles
30000 cycles
35000 cycles
40000 cycles
45000 cycles
50000 cycles
500 cycles
1000 cycles
1500 cycles
2000 cycles
2500 cycles
3000 cycles
3500 cycles
4000 cycles
4500 cycles
5000 cycles (default setting)
5500 cycles
6000 cycles
EN - 31