Menu 1 Basic settings loading bridges
Overcurrent hydraulic motor (menu item 10)
Depending on the set current value, the control switches off the
pump if this value is exceeded.
In order to set the correct current value for the overcurrent, you
have to determine the actual value first. For adjusting, proceed as
follows:
1.
Select menu 1 "Basic settings loading bridge" in the control
and go to menu item 10 "Overcurrent motor pump".
2.
Lift the loading bridge for as long until the overpressure
valve is triggered. This occurs when the highest position of
the loading bridge is reached.
3.
Press and hold the
ð
The display now indicates the achieved actual value.
This occurs when the highest position of the loading
bridge is reached.
4.
Set the overcurrent value in a way that the value exceeds
the determined actual value by 1.
Defect on control or hydraulic system caused
NOTICE
by incorrect parameter
Incorrect settings can result in damages to the
control or hydraulic system. Adjust the parameter
to the hydraulic system used.
Automatic time (menu item 13)
The automatic time determines for how long the loading bridge is
lifted after actuating the return button in order to lower it safely
into the resting position afterwards.
To set the time duration for the automatic time, select the desired
value in the menu.
Defect caused by incorrect setting of
NOTICE
automatic time
Incorrect settings can result in damages to the
control or hydraulic system. Adjust the parameter
to the hydraulic system used.
Automatic retraction (menu item 14)
In the menu, select a value for the desired time during which the
support retracts to perform correction after letting go of the
ton.
Wheel chock / Resting position sensor (menu item 15)
If a wheel chock is connected to J6, the chock has to be activated
in the control. With the function being switched on, the loading
bridge's lifting function will only be enabled if the wheel chock is
activated. If a resting position sensor is connected, the resting po-
sition of the control is initiated if the sensor is activated. All valves
will be switched off. Select one of the following values in the
menu:
•
Value 0 = without function (default setting)
•
Value 1 = with wheel chock sensor
•
Value 2 = resting position sensor
Operating option loading bridge – door (menu item 17)
For initial use, the control is set to value 4 "only loading bridge
operation" in menu item 17. Once you put the door into service,
you have to adjust the value to the actual conditions.
Damages to door and loading bridge caused
NOTICE
by collision
Ensure that door and loading bridge cannot dam-
age each other.