Hilti DD 110-W Manual Del Usuario página 20

Ocultar thumbs Ver también para DD 110-W:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Malfunction
The diamond core bit doesn't
rotate.
The drilling speed is decreas-
ing.
The diamond core bit can't be
fitted into the chuck.
Water escapes at the water
swivel or gear housing.
Water escapes from the
chuck during operation.
14
English
Possible cause
The diamond core bit has become
jammed in the base material.
Maximum drilling depth has been
reached.
The core is stuck in the diamond
core bit.
Wrong core bit specification for the
base material.
High steel content (indicated by
clear water containing metal cut-
tings).
The diamond core bit is defective.
Wrong gear selected.
Contact pressure is too low.
The machine has too little power.
The diamond core bit is polished.
The water flow rate is too high.
The water flow rate is too low.
Dust is hindering drilling progress.
The core bit connection end or
chuck is dirty or damaged.
The water pressure is too high.
The diamond core bit isn't securely
tightened in the chuck.
The core bit connection end /
chuck is dirty.
The seal at the chuck or at the
connection end is defective.
Action to be taken
▶ Guide the diamond core drilling
machine in a straight line.
▶ Use an open-end wrench to
release the diamond core bit:
Disconnect the mains plug from
the power outlet. Grip the
diamond core bit with a suitable
open-end wrench close to the
connection end and release the
diamond core bit by rotating it.
▶ Remove the core and use a core
bit extension.
▶ Remove the core.
▶ Select a more suitable diamond
core bit specification.
▶ Select a more suitable diamond
core bit specification.
▶ Check the diamond core bit
for damage and replace it if
necessary.
▶ Select the right gear.
▶ Increase the contact pressure.
▶ Select the next lower gear.
▶ Sharpen the diamond core bit
by drilling into a sharpening
plate.
▶ Reduce the water flow rate
by adjusting the water flow
regulator.
▶ Check the water supply to
the diamond core bit or,
respectively, increase the water
flow by adjusting the water flow
regulator.
▶ Use a suitable dust removal
system.
▶ Clean and grease the connec-
tion end and/or the chuck or
replace these parts.
▶ Reduce the water pressure.
▶ Tighten the diamond core bit
securely.
▶ Remove the core bit. Rotate the
diamond core bit approx. 90°
about its own axis. Refit the
diamond core bit.
▶ Clean and grease the connec-
tion end and/or the chuck.
▶ Check the seal and replace it if
necessary.
351007
*351007*
Tabla de contenido
loading

Tabla de contenido