Mitsubishi Electric Mr. SLIM MSZ-FA25VA Technical Manual página 652

Ocultar thumbs Ver también para Mr. SLIM MSZ-FA25VA:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Esquemas eléctricos
PKA-RP60FAL
SYMBOL
NAME
P.B
INDOOR POWER BOARD
I.B
INDOOR CONTROLLER BOARD
FUSE FUSE(T6.3AL250V)
ZNR
VARISTOR
CN2L CONNECTOR(LOSSNAY)
CN32 CONNECTOR(REMOTE SWITCH)
CN41 CONNECTOR(HA TERMINAL-A)
CN51 CONNECTOR(CENTRALLY CONTROL)
SW1 SWITCH (MODEL SELECTION) wSee Table 1.
SW2 SWITCH (CAPACITY CODE) wSee Table 2.
SWE SWITCH(EMERGENCY OPERATION)
X4
RELAY(FAN MOTOR)
BCR
FAN CONTROL ELEMENT
LED1 POWER SUPPLY(I.B)
LED2
POWER SUPPLY(R.B)
LED3
TRANSMISSION(INDOOR-OUTDOOR)
P.B
MF
1
2 3
C
I.B
POWER
1 3 5
FAN
CNDK
( WHT )
(RED)
X4
BCR
X4
LED3 LED2 LED1
SWE
SW2
SW1
ON
OFF
Refer to tables 1
and 2 for service PCB.
Table 1
SW1
Service board
1 2 3 4 5
HEATER
CN24
1
2
(YLW)
I.B
6
1
GRY
88H
NOTES:
1. Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing.
2. Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal numbers (S1, S2, S3).
3. Make sure that the main power supply of the booster heater is independent.
4. Symbols used in wiring diagram above are,
1. When work to supply power separately to Indoor and Outdoor unit was applied, refer to Fig 1.
2. For power supply system of this unit, refer to the caution label located near this diagram.
652
PKA-RP71FAL
PKA-RP100FAL
SYMBOL
C
CAPACITOR(FAN MOTOR)
FAN MOTOR
MF
MV
VANE MOTOR
TERMINAL BLOCK (HEATER) wPKH-P.FALH
TB2
models only or option for PKA-RP.FAL models.
TB4
TERMINAL BLOCK(INDOOR/OUTDOOR
CONNECTING LINE)
TB5
TERMINAL BLOCK(REMOTE CONTROLLER
TRANSMISSION LINE )(OPTION)
TH1
ROOM TEMP.THERMISTOR
(0; /15k , 25; /5.4k DETECT)
TH2
PIPE TEMP.THERMISTOR/LIQUID
(0; /15k , 25; /5.4k DETECT)
TH5
COND./EVA.TEMP.THERMISTOR
(0; /15k , 25; /5.4k DETECT)
CNDK
CN2S
(RED)
(WHT)
1
1
2
2
DC13.1V
3
POWER
1 3
1 3
1 2
CND
(ORN)
POWER
CN2D(WHT)
CN41
ZNR
CN51
INTAKE
LIQUID
PIPE
CN20
CN21
CN29
( RED )
( WHT )
( BLK )
1 2
1 2
1 2
TH2
TH1
Table 2
Service board
MODELS
1 2 3 4 5
PKA-RP60FAL
ON
ON
PKH-P60FALH
OFF
OFF
PKH-P60
P100FALH models only
H1
26H
RED
6
RED
5
: Connector,
NAME
W.B
R.B
HEATER
Please set the voltage
using the remote controller.
For the setting method,
please refer to the indoor
unit Installation Manual
TB4
YLW
S1
TO
S2
ORN
OUTDOOR
S3
ORN
UNIT
BRN
VANE
1 3
6
CN6V
INDOOR/OUTDOOR
( GRN )
MV
COMMUNICATION
CN3C(BLU)
CN2L
WIRELESS
CN90
( WHT )
CN32
REMOCON
CN22
( BLU )
1 2
2
TRANSMISSION WIRES DC12V
1
TH5
TB5
SW2
Service board
MODELS
MODELS
1 2 3 4 5
PKA-RP71FAL
PKA-RP100FAL
ON
PKH-P71FALH
PKH-P100FALH
OFF
88H
FS1
FS2
RED
RED 5
1
WHT
2
GRN/YLW
: Terminal (block).
SYMBOL
NAME
WIRELESS REMOTE CONTROLLER BOARD
RU
RECEIVING UNIT
BZ
BUZZER
LED1
LED(RUN INDICATOR )
LED2
LED(HOT ADJUST)
SW1
SWITCH(HEATING ON/OFF)
SW2
SWITCH(COOLING ON/OFF)
WIREDREMOTE CONTROLLER BOARD(OPTION)
TB6
TERMINAL BLOCK(REMOTE CONTROLLER
TRANSMISSION LINE)
FS1,2
THERMAL FUSE(117; 10A:60,71FALH/
117; 16A:100FALH)
H1
HEATER
26H
HEATER THERMAL SWITCH
88H
HEATER CONTACTOR
w
1 (Fig.1)
TB2
L
RED
BLU
N
GRN/YLW
TB4
YLW
S1
ORN
S2
ORN
BRN
S3
I.B
1
3
1
3
POWER
INDOOR/OUTDOOR
CND
COMMUNICATION
(ORN)
CN3C
(BLU)
9
CNB
BZ
RU
RECEIVER
LED1 LED2 SW2 SW1
R.B
Service board
1 2 3 4 5
ON
OFF
TB2
L
3
RED
POWER SUPPLY
N
BLU
(1PHASE)
230V 50Hz
POWER
SUPPLY
(1PHASE)
230V 50Hz
TO
OUTDOOR
UNIT
W.B
1
TB6
2

Hide quick links:

Tabla de contenido
loading

Este manual también es adecuado para:

Mr. slim msz-fa35vaMr. slim muz-fa25vaMr. slim muz-fa35vaMr. slim msz-ga22vaMr. slim msz-ga25vaMr. slim msz-ga35va ... Mostrar todo

Tabla de contenido