Indoor unit operates by pressing EMERGENCY OPERATION switch, but does not operate with the remote controller.
Check of remote controller and indoor electronic control P.C. board
B
Check if the remote controller is exclusive for this air conditioner.
Press OPERATE/STOP(ON/OFF)
button on the remote controller.
Is LCD display on the the remote
controller visible?
Yes
Remove the batteries, then set them back
and press RESET button. (Refer to 10-1.4.)
Check if the unit operates with the remote
controller.
Does the unit operate with the
remote controller?
Yes
OK
No
Replace the batteries. (Refer to 10-1.4.)
(not clear)
Turn ON a radio to AM and press
No
OPERATE/STOP(ON/OFF) button on
the remote controller.
Is noise heard from radio?
Yes
Are there any fluorescent lights of
inverter or rapid-start type within
the range of 1m?
No
Replace the indoor electronic
control P.C. board.
(including the receiver)
Resolución de averías
No
Replace the remote controller.
Yes
● Reinstall the unit away from lights.
● Attach a filter on receiving part.