PROBLEM SOLVING
If there is an anomaly or a problem in the operation of the induction hob,
screen 3 will show the detected error. Error messages appear on the screen
with the letter " E " followed by a number, refer to the following table to identify
the error and the solution.
Mesage
There is no pot, the pot is not suitable
E0
for induction or the diameter of its
base is less than 12 cm
Low voltage or over voltage
E1, E2
protection
IGBT sensor is faulty
E3
The ceramic glass base or plate has
E5
overheated (> 280 ° C)
The IGBT sensor has a temperature
E6
higher than 105 ° C and the
overheating protection has tripped
MANTENIMIENTO Y LIMPIEZA
Antes de proceder a la limpieza desconecte la unidad de la red eléctrica. Y
asegúrese que la placa está totalmente fría. No utilice alcohol ni productos
abrasivos y no permita que el aparato entre en contacto con agentes volátiles
como gasolina, disolventes, insecticidas, etc.
Cleaning the hob
After each use, you should clean the hob, in this way you will prevent the
adhering remains from burning.
Do not clean the hob until it is cool enough.
Use only specific products for cleaning induction hobs, otherwise it could
damage the cooking surface.
Do not use scourers that can scratch the surface, nor should you use
abrasive products such as stain remover sprays for ovens.
Cleaning the casing
Clean the plastic surface with a damp cloth, followed by a dry one. Avoid
getting water through the ventilation holes.
If you notice that a lot of dirt has accumulated in the fan holes, remove it
with the help of a brush.
Description
Place a container on the cooking zone or
replace the invalid container.
If the voltage at the mains outlet is lower or
higher than specified, consult a qualified
electrician.
Contact the closest MX ONDA Official
Technical Service.
Unplug the induction hob and wait for it to
cool down.
Ventilation system failure, check that the
fan is not obstructed and that it is working
properly.
11