Remove the DC Sensor

Close the control stop valve.
Using a 3/32" hex wrench, remove the setscrew from the cap.
Carefully lift the cap from the valve body.
Grasp each side of the connector pair, then pull apart the DC
sensor connector from the solenoid. Do not separate the
connector pair by pulling on the wires.
Position the cap on its side.
Using a 3/32" hex wrench, loosen the screw of the wedge lock
system (not shown) that holds the DC sensor in place inside the
cap.
Turn the cap over and slide the sensor into your hand.
NOTE: The batteries inside the sensor may be considered hazardous
waste. Discard the old sensor and/or batteries in accordance with
any applicable codes.
If replacing the DC sensor, discard the old DC sensor and
batteries.