Clean/Replace The Diaphragm - Kohler K-10673 Guía De Mantenimiento

Ocultar thumbs Ver también para K-10673:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Cap
DC Sensor
Connector
Retaining Nut
Solenoid
Connector
Pin
Diaphragm

Clean/Replace the Diaphragm

NOTICE: Ensure that the wires do not get caught between the cap
and the valve body.
Close the control stop valve.
NOTE: If the unit has not flushed since the stop valve was closed,
the inlet arm may still be pressurized. Use manual flush button to
release pressure.
Using a 3/32" hex wrench, remove the setscrew from the cap.
Remove the cap from the valve body.
Pull the connectors apart to disconnect the DC sensor connector
from the solenoid connector.
Temporarily store the cap and DC sensor assembly in a safe
place.
Using an adjustable wrench, remove the solenoid.
Remove the diaphragm.
NOTE: Take care not to lose any small parts contained within the
solenoid assembly.
Rinse any debris from the diaphragm.
If replacing, insert a new diaphragm in the valve.
Insert the diaphragm with the plastic side facing out from the
valve.
1108709-5-C
All manuals and user guides at all-guides.com
Setscrew
Solenoid
Assembly
Spring
Valve Body
14
O-Ring
Piston
Cover
Piston
Kohler Co.