Connecting The Door Station; Fitting The Name Tag - SOMFY V 350 Manual De Instalacion Y Uso

Ocultar thumbs Ver también para V 350:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 94
EN
5.2 Connecting the door station
5.2.1 Connecting to a Somfy gate motorisation
Note: When the motorisation is solar-powered, the wired controls are deactivated. In this case, you must use the monitor's
wireless control to control your gate motorisation (see page 12).
[1]. Disconnect the motor from the mains power supply.
[2]. Remove the cover from the control cabinet or from the motor containing the electronics.
[3]. Connect the door station dry contact output (COM and NO) to the motorisation electronics. It is best to consult the gate
motorisation instructions to connect the door station to the key contact input on the motorisation.
M- M+ L- L+ NO COM NC
Connect...
COM
NO
Note: To connect the door station to another gate motorisation model, please refer to the installation instructions for that
motorisation.
5.2.2 Connecting to an electric latch/lock
Connect the
door station output to the latch/lock in accordance
with the diagram opposite.
Observe the +/- polarity if indicated in the latch/lock instructions.
5.3 Fitting the name tag
[1]. Turn the call button anticlockwise to the engraved marking then
remove.
[2]. Remove the round to access the name plate label.
[3]. Write your name on the white label using a permanent marker,
then refit the label and its cove in the housing.
[4]. Reassemble the call button on the door station using the marks,
and then turn clockwise until it locks.
9
to the START terminals
5
6
Somfy motorisations electronics
to the BUS terminals
3
4
* not provided
Copyright© 2021 SOMFY ACTIVITES SA. All rights reserved.
V®350 video entry phone
to the numbered terminals
3
5 (for complete opening)
or
6 (for pedestrian opening)
L- L+
12V 800 mA max
*
Tabla de contenido
loading

Tabla de contenido