Roger B70/2ML Instrucciones Y Advertencias Para El Instalador página 71

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 142
(1)
seconds by pressing CHB on the remote control. Press CHB to activate partial opening.
Selecting courtesy light mode
NOTE: The parameter is not visible if par.
Disabled.
ACTIVE. The light remains lit for the entire duration of the manoeuvre.
From 3 to 90 s. The light remains lit for the time period set after the manoeuvre is completed.
From 2 to 9 minutes. The light remains lit for the time period set after the manoeuvre is completed.
NOTE: This parameter is visible only if par.
When the clock function is active, the gate opens and remains open.
At the end of the programmed time set with the external device (clock), the gate closes.
When the clock function is active, the gate opens and remains open. Any command signal received is ignored.
When the clock function is active, the gate opens and remains open. Any command signal received is accepted. When
the gate returns to the completely open position, the clock function is reactivated.
Enable safeguarded gate closure/opening
This function is NOT
the gate receives a STOP command;
the sensitive edge intervenes, detecting an obstacle in the same direction in which the function is enabled. If instead
the sensitive edge detects an obstacle during the movement opposite to the one guaranteed, the function remains
active.
the number of closure attempts set by parameter
the acquired position is lost (perform position recovery, see chapter 17).
Disabled. The parameter
Safeguarded closure enabled.
After a period of time set with parameter
less of the parameter
If the gate is closed as a result of a step mode command, after a period of time set with parameter
If the gate is stopped by the obstacle detection system during a closure manoeuvre, the gate closes after a period of
time set with parameter
If the gate is stopped by the obstacle detection system during an opening manoeuvre, the gate closes after a period of
time set with parameter
Setting safeguarded closure/opening activation time
N.B.: this parameter is not visible if the value of parameter
Wait time settable from 2 to 90 s.
Wait time settable from 2 to 9 min.
Selecting limitations in battery operation
N.B.: the parameter is visible only if par.
There is no limitation for the commands when the battery voltage drops under the selected threshold. An error alert may
be activated via the COR output (if parameters
When the battery voltage drops under the threshold selected with par.
commands and does not perform closing.
When the battery voltage drops under the threshold selected with par.
automatically opens the barrier's boom and accepts only a closing command.
It accepts only closing commands even if the ORO input is active and if the parameter is
When the battery voltage drops to the threshold selected with par.
automatically closes the gate and accepts only one opening command.
Battery consumption selection
and
is other than
(ORO)
is
is not displayed.
, and then closes the gate.
.
.
is different than
has been reached;
=
.
and
are adequately set).
, the control unit accepts only opening
the control unit, after a prelamping of 5s,
, the control unit
), and then the gate closes.
.
71
Tabla de contenido
loading

Tabla de contenido