9.2

Command and safety device status display mode

COMMAND STATUS
AP
PED
PP
ORO
CH
POWER
9.3

TEST mode

To activate the mode, press the TEST button with the automatic gate system at rest. If the gate is moving, pressing
TEST stops the gate. Pressing the button again enables TEST mode.
device is activated.
The command signal status is shown on the left hand side of the display for 5 seconds, ONLY when the respective
command signal is active (AP, CH, PP, PE, OR). For example, if the gate open command is activated, the letters AP
appear on the display.
NOTA: If one or more contacts are open, the gate will not open or close.
the next device is displayed. Any further alarm states are also displayed with the same logic.
Press the TEST button again to exit test mode.
After 10 seconds with no user input, the display returns to command and safety device state display mode.
9.4

Standby mode

This mode is activated after 30 minutes with no user input. The POWER LED
Press UP
, DOWN
, + , - to reactivate the control unit.
SAFETY DEVICE STATUS
FT1
FT2
COS
STOP
is
; the segment COS only, if par.
COMMAND STATUS:
The command status indicators on the display
(segments AP = open, PP = step mode, CH = close,
PED = partial opening, ORO= clock) are normally
off. They illuminate when a command is received
segment PP illuminates).
SAFETY DEVICE STATUS:
The safety device status indicators on the display
(segments
STOP) are normally on. If an indicator is off, the
relative device is in alarm state or is not connected.
No safety device in alarm state, and no limit switch activated
STOP.
Sensing edge COS (if enabled with par.
Photocell FT1.
Photocell FT2.
POWER
photocells, COS= sensing edge,
is
.
set to
).
59