Type 0 (zero) for image update.
3
Change the remote system's baud rate to 115200 (see "Setting Up the Remote System
4
Serial Connection Baud Rate").
Click Send to access the Send File dialog box.
5
Select Xmodem protocol.
6
Browse and select the file runtimexxx.bix, where xxx is the version of the runtime
7
component.
Click Send to download the file.
8
The download takes approximately 5 minutes.
After the download is complete, press <r> to update the runtime component.
9
Type runtime for the filename.
10
After the update is complete, change the remote system's baud rate to 9600 (see
11
"Setting Up the Remote System Serial Connection Baud Rate").
To update other components, press any key to continue, and proceed to "Updating the
12
Diagnostics Component" or "Updating the Loader Component."
If you are not updating any other components, remove the network switch module and
move the jumper back to pins 1 and 2 (default).
NOTE: If you do not move the jumper back to pins 1 and 2, you will not be able to use
ERA/MC console redirection to log into the network switch module.
Replacing the Server Module Battery
CAUTION: Only trained service technicians are authorized to remove and access
any components inside the system. See your System Information Guide for
complete information about safety precautions, working inside the computer,
and protecting against electrostatic discharge.