Optional Features - Ferroli FORCE W 60 Instrucciones De Uso, Instalación Y Mantenimiento

Ocultar thumbs Ver también para FORCE W 60:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 72
FORCE W
- Parameters
Each system requires a different parameterization. Follow the access procedure given below.
"System Type Menu"
Change parameter P.01 of the "System Type Menu" to 4.

- Optional features

In addition to the electrical connections of the previous figure (necessary for this system configuration) there are options
that do not require settings.
1
2
3
4
5
6
7
8
L N
302
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
139
37 38 39 40 41 42 43 44
fig. 44
EN
9 10 11 12 13 14 15 16 17 18
300
301
357
N
L
cod. 3541V232 - Rev 00 - 08/2021
Legend
139 Remote control: it can be installed instead of 72
to manage the request of the 1st zone (direct)
300 Burner on indication (voltage-free contact out-
put): the example shows the connection of a 230
Vac hour meter
301 Fault indication (voltage-free contact output): the
example shows the connection of a 230Vac
lamp
302 Remote reset input (230Vac): the example
shows the connection of a double-pole switch at
230Vac, allowing the resetting of a block type
fault
357 Fault indication (230Vac): the example shows
the connection of a 230Vac lamp