Ferroli FORCE W 60 Instrucciones De Uso, Instalación Y Mantenimiento

Ferroli FORCE W 60 Instrucciones De Uso, Instalación Y Mantenimiento

Ocultar thumbs Ver también para FORCE W 60:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 72

Enlaces rápidos

FORCE W
ISTRUZIONE PER L'USO L'INSTALLAZIONE E LA MANUTENZIONE
IT
INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO
ES
RO
INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
EN
INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN
FR
RU
PL
Tabla de contenido

Solución de problemas

loading

Resumen de contenidos para Ferroli FORCE W 60

  • Página 1 FORCE W ISTRUZIONE PER L’USO L’INSTALLAZIONE E LA MANUTENZIONE INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE INSTRUCTIONS D’UTILISATION, D’INSTALLATION ET D’ENTRETIEN...
  • Página 2 FORCE W • Leggere attentamente le avvertenze contenute in • Per garantire il buon funzionamento dell’apparec- questo libretto di istruzioni in quanto forniscono im- chio è indispensabile fare effettuare da personale portanti indicazioni riguardanti la sicurezza di instal- qualificato una manutenzione periodica. lazione, l’uso e la manutenzione.
  • Página 3: Tabla De Contenido

    FORCE W 1 Istruzioni d’uso ........................4 1.1 Presentazione ............................4 1.2 Pannello comandi........................... 4 1.3 Accensione e spegnimento ........................8 1.4 Regolazioni............................. 9 2 Installazione ........................... 17 2.1 Disposizioni generali ..........................17 2.2 Luogo d’installazione ..........................17 2.3 Collegamenti idraulici ........................... 17 2.4 Collegamento gas ..........................
  • Página 4: Istruzioni D'uso

    1.1 Presentazione Gentile cliente, La ringraziamo di aver scelto FORCE W, una caldaia murale a camera stagna FERROLI di concezione avanzata, tec- nologia d’avanguardia, elevata affidabilità e qualità costruttiva. La preghiamo di leggere attentamente il presente ma- nuale perchè fornisce importanti indicazioni riguardanti la sicurezza di installazione, uso e manutenzione.
  • Página 5 FORCE W Tasti diretti I tasti diretti (part. 8, 9, 10 - fig. 1) hanno sempre la stessa funzione. Tasti navigazione/menù I tasti navigazione/menù (part. 5, 6, 7, 11, 12, 13 - fig. 1) servono per navigare tra i vari menù implementati nel pannello di controllo.
  • Página 6 FORCE W MANUTENZIONE Vedi fig. 76 Modalità Test Vedi fig. 72 Modalità Test Selezione Tipo Gas Modalità Test Cascata Vedi “Informazione Service” a pag. 14 Informazione Service Vedi “Data Intervento Service” a pag. 14 Data Intervento Service IMPOSTAZIONI Vedi fig. 8 Lingua Unità...
  • Página 7 FORCE W Esclusione bollitore (economy) Il riscaldamento/mantenimento in temperatura del bol- litore può essere escluso dall'utente. In caso di esclu- sione, non vi sarà erogazione di acqua calda sanitaria. Il bollitore può essere disattivato dall’utente (modalità ECO) premendo il tasto eco/comfort (part. 10 - fig. 1). 23°C 32°C In modalità...
  • Página 8: Accensione E Spegnimento

    FORCE W 1.3 Accensione e spegnimento Accensione caldaia Premere il tasto d’accensione/spegnimento (part 14 - • Scomparsa la scritta FH, la caldaia è pronta per fig. 1). funzionare automaticamente ogni qualvolta vi sia una richiesta al termostato ambiente. Premendo il tasto contestuale 1 è possibile scegliere la lingua desiderata e confermarla attraverso il tasto “OK”.
  • Página 9: Regolazioni

    FORCE W Spegnimento caldaia Dalla schermata principale/Home, premere il tasto contestuale e confermare con il tasto Quando la caldaia viene spenta, la scheda elettronica è ancora alimentata elettricamente. È disabilitato il funzionamento sanitario (con bollitore opzionale installato) e riscaldamento. Rimane attivo il sistema antigelo.
  • Página 10 FORCE W Riduzione della temperatura riscaldamento Accedere al menù “Temp Regolazione Riduzione” Temp Regolazione Riduzione per variare la temperatura da un minimo di 0°C ad un massimo di 50°. Confermare con il tasto OK. Questo parametro viene utilizzato solo se è attivata la programmazione oraria.
  • Página 11 FORCE W Selezionare il giorno (fig. 17) o l’intervallo di giorni da programmare (fig. 18) e confermare con il tasto OK. Programma Orario Programma Orario Mercoledì Lunedì Giovedì Martedì Venerdì Mercoledì Sabato Giovedì Domenica Venerdì Lunedì-Domenica Sabato Lunedì-Venerdì Domenica Sabato-Domenica Lunedì-Domenica per confermare per confermare...
  • Página 12 FORCE W Premere il tasto di navigazione 7 ed utilizzare i tasti Programma Orario contestuali 1 e 2 per impostare la modalità di lavoro durante la prima fascia oraria (fig. 21) 06:00 - 16:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:--...
  • Página 13 FORCE W Per ripristinare il programma orario ai valori Programma Orario di fabbrica, premere il tasto contestuale 3 nel menù Programma Orario (fig. 26) e con- Lunedì fermare con OK. Martedì Mercoledì Giovedì Venerdì Sabato Domenica Lunedì-Domenica per confermare fig. 26 I due programmi orari Riscaldamento e Sanitario sono indipendenti anche in caso di Ripristino al valore di fab- brica.
  • Página 14 FORCE W Funzione Vacanze Accedere al menù “FUNZIONE VACANZA” attraverso il percorso “MENÙ UTENTE “FUNZIONE VACANZA” per po- ter impostare: • Data inizio Vacanza. • Data fine Vacanza. Il display può attivare due tipi di icone: • - La funzione Vacanze é programmata ma non ancora attiva. •...
  • Página 15 FORCE W Regolare lo spostamento parallelo delle curve da 20 a Offset 1 60 °C (fig. 31), attraverso il parametro “Offset1” e confermare con il tasto OK. per confermare fig. 29 - Spostamento parallelo delle curve Se la temperatura ambiente risulta inferiore al valore desiderato si consiglia di impostare una curva di ordine superiore e viceversa.
  • Página 16 FORCE W Regolazioni da cronocomando remoto Se alla caldaia è collegato il Cronocomando Remoto (opzionale), le regolazioni descritte in precedenza ven- gono gestite secondo quanto riportato nella tabella 1. Tabella 1 Regolazione temperatura riscalda- La regolazione può essere eseguita sia dal menù del Cronocomando Remoto sia dal pan- mento nello comandi caldaia.
  • Página 17: Installazione

    FORCE W 2. Installazione 2.1 Disposizioni generali L'INSTALLAZIONE DELLA CALDAIA DEVE ESSERE EFFETTUATA SOLTANTO DA PERSONALE SPECIALIZZATO E DI SICURA QUALIFICAZIONE, OTTEMPERANDO A TUTTE LE ISTRUZIONI RIPORTATE NEL PRESENTE MA- NUALE TECNICO, ALLE DISPOSIZIONI DI LEGGE VIGENTI, ALLE PRESCRIZIONI DELLE NORME NAZIONALI E LOCALI E SECONDO LE REGOLE DELLA BUONA TECNICA.
  • Página 18 FORCE W Circolatore ad alta efficienza (opzionale) L'impostazione di fabbrica é idonea per tutte le installazioni; tuttavia, è possibile impostare, tramite il selettore di velocità (vedi fig. 33), una strategia di funzionamento diversa in funzione delle caratteristiche dell'impianto. 1 2 3 fig.
  • Página 19: Impianto Esistente

    FORCE W Caratteristiche dell’acqua impianto Prima di procedere all'installazione del generatore FORCE W, l'impianto, nuovo o esistente, deve essere opportuna- mente pulito allo scopo di eliminare residui installativi, solventi, fanghi e contaminanti in genere che possano precludere l'efficacia dei trattamenti condizionanti di protezione. Utilizzare prodotti di pulizia neutri non aggressivi verso metalli, gomma e parti in plastica del generatore/impianto.
  • Página 20 FORCE W Verificare sempre la concentrazione di prodotto dopo ogni inserimento e ciclica- mente, almeno una volta all'anno avvalendosi di personale tecnico qualificato qua- le la nostra rete di assistenza tecnica autorizzata. Tabella 2 - Condizionanti chimici dichiarati idonei e disponibili presso la nostra rete di Centri Assi- stenza Tecnica Autorizzata Descrizione Prodotti alternativi tipo Sentinel...
  • Página 21: Kit Opzionali

    FORCE W Kit opzionali A richiesta sono disponibili i seguenti kit: cod. 042070X0 - KIT CIRCOLATORE ad ALTA EFFICIENZA - 7m. (A - fig. 37) cod. 042071X0 - KIT CIRCOLATORE ad ALTA EFFICIENZA - 10m. (A - fig. 37) cod. 042072X0 - KIT IDRAULICO Nel Kit 042072X0 sono contenuti: VALVOLA DI NON RITORNO - Femmina 1”1/2 (B - fig.
  • Página 22 FORCE W Esempi circuiti idraulici Negli esempi descritti in seguito potrebbe essere ri- MENU chiesto di verificare/modificare alcuni parametri. Per fare questo è necessario accedere al menù Tec- UTENTE nico. Dalla schermata principale (Home), premere il tasto TECNICO Menù principale (part. 12 - fig. 1). Accedere al menù...
  • Página 23: Collegamenti Elettrici

    FORCE W Due circuiti riscaldamento diretti - Schema di principio fig. 42 - Collegamenti elettrici Dopo l’installazione, sarà necessario effettuare i collegamenti elettrici necessari come riportato nello schema elettrico. Successivamente, procedere alla configurazione della centralina come riportato nell’apposito paragrafo. Legenda (fig. 42 e fig. 43) 9 10 11 12 13 14 15 16 17 18 Termostato ambiente 1a zona (diretta) 72b Termostato ambiente 2a zona (diretta)
  • Página 24 FORCE W - Parametri Ogni impianto necessita di una diversa parametrizzazione. Seguire la procedura d’accesso riportata di seguito. “Menù Tipo Impianto” Modificare parametro P.01 del “Menù Tipo Impianto” a 4. - Funzionalità opzionali Oltre ai collegamenti elettrici della precedente figura (necessari a questa configurazione d’impianto) esistono delle op- zioni che non necessitano di impostazioni.
  • Página 25 FORCE W Un circuito riscaldamento diretto ed un circuito sanitario con circolatore - Schema di principio fig. 45 - Collegamenti elettrici Dopo l’installazione, sarà necessario effettuare i collegamenti elettrici necessari come riportato nello schema elettrico. Successivamente, procedere alla configurazione della centralina come riportato nell’apposito paragrafo. Legenda (fig.
  • Página 26 FORCE W - Parametri Ogni impianto necessita di una diversa parametrizzazione. Seguire la procedura d’accesso riportata di seguito. “Menù Parametri - Configurazione” Verificare/Modificare parametro b02 del “Menù Parametri Trasparenti” a 8. Verificare/Modificare parametro b08 del “Menù Parametri Trasparenti” a 1. Verificare/Modificare parametro b04, b05 e b06 del “Menù...
  • Página 27 FORCE W Un circuito riscaldamento diretto ed un circuito sanitario con valvola deviatrice (a 3 fili) - Schema di principio Utilizzare valvole deviatrici a 3 fili: - FASE APERTURA 230V - FASE CHIUSURA 230V - NEUTRO con tempi di commutazione (da tutto chiuso a tutto aperto) non superiori a 90 secondi. fig.
  • Página 28 FORCE W Legenda (fig. 48 e fig. 49) Circolatore riscaldamento 1a zona (diretta) Termostato ambiente 1a zona (diretta) Circuito bollitore 138 Sonda esterna Mandata 155 Sonda bollitore Ritorno 348 Valvola a 3 vie (a tre fili) K1 - K2bobina 230 Vac , < 2,2 VA A = FASE APERTURA contatto 230Vac , >...
  • Página 29 FORCE W Due circuiti riscaldamento miscelati, un circuito riscaldamento diretto e un circuito sanitario con circolatore - Schema di principio La scheda controllo zone FZ4B può gestire diverse tipologie d’impianto. Quello riportato è un esempio. Utilizzare valvole deviatrici a 3 fili: - FASE APERTURA 230V - FASE CHIUSURA 230V - NEUTRO...
  • Página 30 FORCE W - Collegamenti elettrici Dopo l’installazione, sarà necessario effettuare i collegamenti elettrici necessari come riportato nello schema elettrico. Successivamente, procedere alla configurazione della centralina come riportato nell’apposito paragrafo. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 L _ N L _ N L _ N...
  • Página 31 FORCE W Legenda (fig. 51 e fig. 52) 72a Termostato ambiente 1a zona (miscelata) B = NEUTRO 72b Termostato ambiente 2a zona (miscelata) C = FASE CHIUSURA 72c Termostato ambiente 3a zona (diretta) 317a Termostato di sicurezza 1a zona (miscelata) 130 Circolatore bollitore 317b Termostato di sicurezza 2a zona (miscelata) 138 Sonda esterna...
  • Página 32: Collegamento Gas

    FORCE W 2.4 Collegamento gas Prima di effettuare l’allacciamento, verificare che l’apparecchio sia predisposto per il funzionamento con il tipo di combustibile disponibile ed effettuare una accurata pulizia di tutte le tubature gas dell’impianto, per rimuovere eventuali residui che po- trebbero compromettere il buon funzionamento della caldaia.
  • Página 33 FORCE W tuata tramite collegamento diretto dalla rete o tramite pile, a seconda del tipo di di- spositivo. Sonda esterna (optional) Collegare la sonda ai rispettivi morsetti. La massima lunghezza consentita del cavo elettrico di collegamento caldaia – sonda esterna è di 50 m. Può essere usato un comune cavo a 2 conduttori. La sonda esterna va installata preferibil- mente sulla parete Nord, Nord-Ovest o su quella su cui si affaccia la maggioranza del locale principale di soggiorno.
  • Página 34 FORCE W Per il collegamento in cascata NOTA: l’elettronica di caldaia è in grado di gestire fino ad un massimo di 6 moduli. 1. Collegare i moduli come mostrato in fig. 56 (esempio con 3 moduli) fig. 56 - Collegamento in cascata A 1°...
  • Página 35 FORCE W Generatori in cascata: un circuito riscaldamento diretto e un circuito sanitario con circolatore Schema di principio L’elettronica di caldaia è in grado di gestire fino ad un massimo di 6 moduli. L’esempio ne riporta 3. fig. 57 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 36 FORCE W Collegamenti elettrici Dopo l’installazione, sarà necessario effettuare i collegamenti elettrici necessari come riportato nello schema elettrico. Successivamente, procedere alla configurazione della centralina come riportato nell’apposito paragrafo. 300M 300S 9 10 11 12 13 14 15 16 17 18 9 10 11 12 13 14 15 16 17 18 SLAVE 1 MASTER...
  • Página 37 230Vac “Per ulteriori schemi di collegamento in cascata, idraulico ed elettrico, vi invitiamo a consultare il sito www.ferroli.com nella sezione dedicata ai prodotti RESIDENZIALE, Caldaie, FORCE W e scaricare alla voce MANUALI i documenti tec-...
  • Página 38: Condotti Fumo

    FORCE W 2.6 Condotti fumo LE CALDAIE DEVONO ESSERE INSTALLATE IN LOCALI CHE RISPONDONO AI REQUISITI DI AEREAZIONE FONDAMENTALI. IN CASO CONTRARIO SUS- SISTE PERICOLO DI ASFISSIA O DI INTOSSICAZIONE. LEGGERE LE ISTRUZIONI DI INSTALLAZIONE E DI MANUTENZIONE PRIMA DI INSTALLARE L’APPARECCHIO. RISPETTARE ANCHE LE ISTRUZIONI DI PROGETTAZIONE.
  • Página 39 TERMINALE Esempi di calcolo FORCE W 60: prevalenza disponibile 77 Pa 5 metri TUBO Ø80 + 3 CURVE Ø80 = (5 x 4,8) + (3 x 10)= 55<77 = OK 8 metri TUBO Ø80 + 6 CURVE Ø80 = (8 x 4,8) + (6 x 10)= 100>77 = NO Condotti fumo Se l'installazione dell'apparecchio è...
  • Página 40: Collegamento Scarico Condensa

    FORCE W È necessario che eventuali tratti orizzontali dello scarico fumi siano mantenuti in leggera pendenza verso la caldaia per evitare che eventuale condensa rifluisca verso l’esterno causando gocciolamento. Prima di procedere con l’installazione, verificare con la tabella 5 che non sia superata la massima lunghezza consentita tenendo conto che ogni curva coassiale dà...
  • Página 41: Servizio E Manutenzione

    Personale Qualificato e di sicura qualificazione (in possesso dei requisiti tecnici professionali previsti dalla normativa vigente) come il personale del Servizio Tecnico Assistenza Clienti di Zona. FERROLI declina ogni responsabilità per danni a cose e/o persone derivanti dalla manomissione dell’apparecchio da parte di persone non qualificate e non autorizzate.
  • Página 42 FORCE W • Per modelli W 60 e W 80 Svitare le viti “B” ed estrarre il gruppo “Venturi/valvola a gas” (fig. 66). Svitare le viti “E” e quindi sostituire l’ugello gas “F” con quello contenuto nel kit di trasformazione posizionandolo all’interno della guarnizione “G”.
  • Página 43 FORCE W • Per il Modelli W 99, W 120 e W 150 Estrarre la centralina della valovla a gas (fig. 68). Svitare le viti “C” (fig. 69) che fissano il ventilatore ed estrarre il gruppo (fig. 70). fig. 68 fig.
  • Página 44 FORCE W • Per tutti i modelli Modificare il parametro relativo al tipo di gas come descritto di seguito. Raggiungere la schermata visualizzata in fig. 72 navigando nel menù seguendo il percorso “MENÙ UTENTE Manutenzione Modalità Test Selezione Tipo Gas”. Premere i tasti contestuali 1 e 2 per scegliere il tipo di gas.
  • Página 45 FORCE W fig. 73 - Regolazione massima modelli W 60 e W 80 fig. 74 - Regolazione minima modelli W 60 e W 80 fig. 75 - Regolazione massima e minima modelli W 99, W 120 e W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 46 FORCE W Attivazione modalità TEST Raggiungere la schermata visualizzata in fig. 76 navigando nel menù seguendo il percorso “MENÙ UTENTE nutenzione Modalità Test Modalità test”. La caldaia si accende raggiungendo il massimo della potenza di riscaldamento (Range Rated), impostata come al pa- ragrafo successivo, in maniera graduale.
  • Página 47: Menù Tecnico

    FORCE W MENÙ TECNICO L’ACCESSO AL MENÙ SERVICE E LA MODIFICA DEI PARAMETRI PUÒ ESSERE EFFETTUATA SOLO DA PER- SONALE QUALIFICATO. L’accesso al Menù Tecnico è possibile solo dopo aver digitato il codice 4 1 8. Ed è valido per 15 minuti. Menù...
  • Página 48 FORCE W Parametro Descrizione Range W 60 W 80 W 99 W 120 W 150 Tempo attesa riscaldamento 0-10 minuti Post Circolazione riscaldamento 0-255 minuti Funzionamento pompa 0-3 Strategia di funzionamento Velocità minima pompa modulante 0-100% Velocità partenza pompa modulante 0-100% Velocità...
  • Página 49 FORCE W Menù Parametri – Tipo Impianto Sono disponibili 23 parametri indicati dalla lettera “P.” i quali non sono modificabili da Cronocomando Remoto. Parametro Descrizione Range W 60 W 80 W 99 W 120 W 150 0 = Normale richiesta riscaldamento 1 = Richiesta da comando remoto con abilitazione on-off esterna 2 = Richiesta segnale 0-10V con controllo in temperatura con abilitazione on-off esterna...
  • Página 50: Messa In Servizio

    FORCE W 3.2 Messa in servizio Verifiche da eseguire alla prima accensione, e dopo tutte le operazioni di manu- tenzione che abbiano comportato la disconnessione dagli impianti o un intervento su organi di sicurezza o parti della caldaia: Prima di accendere la caldaia •...
  • Página 51 FORCE W Controllo periodico Per mantenere nel tempo il corretto funzionamento dell’apparecchio, è necessario far eseguire da personale qualificato un controllo annuale che preveda: • Verifica dello stato dello scambiatore di calore e pulizia con prodotti idonei se sporco o impaccato. La pulizia dello scambiatore può...
  • Página 52 FORCE W Apertura del pannello frontale Alcuni componenti interni alla caldaia possono raggiungere temperature elevate tali da provocare gravi ustioni.Prima di effettuare qualsiasi operazio- ne, attendere che tali componenti si raffreddino o in alternativa indossare guanti adeguati. Per aprire il mantello della caldaia: 1.
  • Página 53 FORCE W Manutenzione straordinaria e sostituzione componenti Sostituzione elettrodo Pulizia scambiatore cod. 3541V232 - Rev 00 - 08/2021...
  • Página 54: Risoluzione Dei Problemi

    FORCE W 3.4 Risoluzione dei problemi Diagnostica La caldaia è dotata di un avanzato sistema di autodiagnosi. Nel caso di un’anomalia alla caldaia, il display si illumina indicando il codice dell’anomalia e, in caso di collegamento in cascata, il numero del modulo. •...
  • Página 55 FORCE W Codice Anomalia Possibile causa Soluzione anomalia Sensore danneggiato Anomalia sensore Cablaggio in corto circuito Verificare il cablaggio o sostituire il sensore ritorno Cablaggio interrotto Sensore danneggiato Anomalia sensore sani- Cablaggio in corto circuito Verificare il cablaggio o sostituire il sensore tario Cablaggio interrotto Sensore danneggiato...
  • Página 56: Caratteristiche E Dati Tecnici

    FORCE W 4. Caratteristiche e dati tecnici Legenda figure cap. 4 Entrata gas - Ø 3/4” Mandata impianto - Ø 1” 1/2 Ritorno impianto - Ø 1” 1/2 Valvola di sicurezza Ventilatore Circolatore riscaldamento (non fornito) Sensore temperatura riscaldamento Sfiato aria automatico Valvola gas Termostato ambiente (non fornito) Secondo Termostato ambiente (non fornito)
  • Página 57: Dimensioni E Attacchi

    FORCE W 4.1 Dimensioni e attacchi fig. 79 - Vista frontale fig. 80 - Vista laterale fig. 81 - Vista dall’alto fig. 82 - Vista dal basso cod. 3541V232 - Rev 00 - 08/2021...
  • Página 58: Vista Generale

    4.2 Vista generale fig. 84 - Vista generale mod. FORCE W 99 e FORCE W 120 fig. 83 - Vista generale mod. FORCE W 60 e FORCE W 80 fig. 85 - Vista generale mod. FORCE W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 59: Circuito Idraulico

    FORCE W 4.3 Circuito idraulico fig. 86 - Circuito idraulico cod. 3541V232 - Rev 00 - 08/2021...
  • Página 60: Tabella Dati Tecnici

    FORCE W 4.4 Tabella dati tecnici Nella colonna a destra viene indicata l’abbreviazione utilizzata nella targhetta dati tecnici. cod. 3541V232 - Rev 00 - 08/2021...
  • Página 61 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 62: Tabelle Erp

    FORCE W 4.5 Tabelle ErP cod. 3541V232 - Rev 00 - 08/2021...
  • Página 63 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 64 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 65 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 66 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 67: Diagrammi

    4.6 Diagrammi Perdita di carico fig. 87 - Diagramma perdita di carico modelli FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 fig. 88 - Diagramma perdita di carico modelli FORCE W 150 Portata - m...
  • Página 68: Schemi Elettrici

    FORCE W 4.7 Schemi elettrici La legenda delle figure si trova a pag. 56. ATTENZIONE: Prima di collegare il termostato ambiente o il cronocomando remoto, togliere il ponticello sulla morsettiera. ATTENZIONE: per il collegamento della valvola 3-vie (morsetti 13 - 14 - 15), fare riferimento agli schemi di fig. 89 e fig.
  • Página 69 FORCE W fig. 92 - Schema elettrico modelli FORCE W 60 e FORCE W 80 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 70 FORCE W fig. 93 - Schema elettrico modelli FORCE W 99, FORCE W 120 e FORCE W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 71 C e r t i f i c a t o d i G a ra n z i a La presente garanzia convenzionale è valida per gli apparecchi...
  • Página 72: Países De Destino: It Es Ro Ru Pl

    FORCE W • Le rogamos leer atentamente las advertencias con- • Desembale el aparato y compruebe que esté en per- tenidas en este manual de instrucciones, ya que fecto estado. Los materiales de embalaje son una proporcionan información importante sobre la insta- fuente potencial de peligro: no los deje al alcance de lación, el uso y el mantenimiento.
  • Página 73 FORCE W 1 Instrucciones de uso ......................74 1.1 Presentación ............................74 1.2 Panel de mando ........................... 74 1.3 Encendido y apagado........................... 78 1.4 Regulaciones............................79 2 Instalación ..........................87 2.1 Disposiciones generales ........................87 2.2 Lugar de instalación ..........................87 2.3 Conexiones de agua ..........................
  • Página 74: Instrucciones De Uso

    1.1 Presentación Estimado cliente: Gracias por elegir FORCE W, una caldera mural con cámara estanca FERROLI de diseño avanzado, tecnología de vanguardia, elevada fiabilidad y calidad constructiva. Le rogamos leer atentamente el presente manual, ya que propor- ciona información importante sobre la instalación, el uso y el mantenimiento.
  • Página 75 FORCE W Teclas directas Las teclas directas ( 8, 9 y 10 - fig. 1) tienen siempre la misma función. Tecla de navegación en menús Las teclas de navegación en menús ( 5, 6, 7, 11, 12 y 13 - fig. 1) permiten recorrer los diversos menús implementados en el panel de control.
  • Página 76: Mantenimiento

    FORCE W MANTENIMIENTO Vea fig. 76 Modo Test Vea fig. 72 Modo Test Selección Tipo Gas Modo Test Cascada Vea “Información Asistencia” on page 84 Información Asistencia Vea “Fecha intervención Asistencia” on page 84 Fecha intervención Asistencia AJUSTES Vea fig. 8 Idioma Unidad de medida Vea fig.
  • Página 77: Exclusión Del Acumulador (Economy)

    FORCE W Exclusión del acumulador (Economy) El calentamiento/mantenimiento en temperatura del acumulador puede ser desactivado por el usuario. En tal caso, no hay suministro de agua caliente sanitaria. Para desactivar el acumulador y establecer el modo ECO, pulse la tecla eco/comfort ( 10 - fig. 1). En 23°C 32°C modo ECO, en la pantalla se visualiza el símbolo...
  • Página 78: Encendido Y Apagado

    FORCE W 1.3 Encendido y apagado Encendido de la caldera Pulse la tecla de encendido/apagado (14 - fig. 1). Seleccione el idioma con la tecla contextual 1 y confír- melo con la tecla “OK”. Pulse la tecla contextual 3 si desea interrumpir el modo FH.
  • Página 79: Regulaciones

    FORCE W Apagado de la caldera Desde la pantalla principal (Inicio), pulse la tecla con- textual y confirme con la tecla Cuando la caldera se apaga, la tarjeta electrónica per- manece conectada. Se deshabilitan la producción de agua sanitaria (con acumulador opcional instalado) y la calefacción.
  • Página 80 FORCE W Reducción de la temperatura de calefacción Acceda al menú “Temp. Regulación Reducción” Temp Regulación Reducida para regular la temperatura desde un mínimo de 0 °C hasta un máximo de 50 °C. Confirme con la tecla OK. Este parámetro se utiliza solamente si está activada la programación horaria.
  • Página 81 FORCE W Seleccione el día (fig. 17) o el intervalo de días que desee programar (fig. 18) y confírmelo con la tecla OK. Programa horario Programa horario Miercoles Lunes Jueves Martes Viernes Miercoles Sabado Jueves Domingo Viernes Lunes-Domingo Sabado Lunes-Viernes Domingo Sabado-Domingo Lunes-Domingo...
  • Página 82 FORCE W Pulse la tecla de navegación 7 y utilice las teclas con- Programa horario textuales 1 y 2 para seleccionar el modo de funciona- miento durante la primera franja horaria (fig. 21). 06:00 - 16:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:--...
  • Página 83: Programa Antilegionela (Con Acumulador Opcional Instalado)

    FORCE W Para restablecer los valores de fábrica del Programa horario programa horario, pulse la tecla contextual 3 en el menú Programa horario (fig. 26) y Lunes confirme con OK. Martes Miercoles Jueves Viernes Sabado Domingo Lunes-Domingo para confirmar fig. 26 Los dos programas horarios, calefacción y ACS, son independientes también para el restablecimiento de los valores de fábrica.
  • Página 84 FORCE W Función Vacaciones Abra el menú "FUNCIÓN VACACIONES" siguiendo la ruta "MENÚ DE USUARIO “FUNCIÓN VACACIONES” para programar: • Fecha de inicio de las vacaciones • Fecha de terminación de las vacaciones En la pantalla pueden aparecer dos tipos de iconos: •...
  • Página 85: Temperatura Exterior Calefacción Off

    FORCE W Regule el desplazamiento paralelo de las curvas de Offset 1 20 a 60 °C (fig. 31) mediante el parámetro “Offset1” y confirme con la tecla OK. para confirmar fig. 29- Desplazamiento paralelo de las curvas Si la temperatura ambiente es inferior al valor deseado, se aconseja seleccionar una curva de orden superior, y vice- versa.
  • Página 86: Regulaciones Desde El Cronomando A Distancia

    FORCE W Regulaciones desde el cronomando a distancia Si la caldera tiene conectado el cronomando a distancia (opcional), las regulaciones descritas anteriormente se realizan según se indica en la tabla 1. Tabla 1 Regulación de la temperatura de cale- Esta regulación se puede hacer tanto en el menú del cronomando a distancia como en el facción panel de mandos de la caldera.
  • Página 87: Instalación

    FORCE W 2. Instalación 2.1 Disposiciones generales LA CALDERA TIENE QUE SER INSTALADA ÚNICAMENTE POR PERSONAL ESPECIALIZADO Y DEBIDAMENTE CUALIFICADO, RESPETANDO TODAS LAS INSTRUCCIONES DEL PRESENTE MANUAL TÉCNICO, LAS LEYES NACIONALES Y LOCALES ASÍ COMO LAS REGLAS DE LA TÉCNICA. 2.2 Lugar de instalación El generador se debe instalar en un local específico, con aberturas de ventilación hacia el exterior, según lo dispuesto por las normas vigentes.
  • Página 88: Circulador De Alta Eficiencia (Opcional)

    FORCE W Circulador de alta eficiencia (opcional) Los ajustes de fábrica son idóneos para todas las instalaciones. No obstante, mediante el selector de velocidad (fig. 33) es posible modificar la estrategia de funcionamiento de acuerdo con las necesidades particulares. 1 2 3 fig.
  • Página 89: Instalación Existente

    FORCE W Características del agua de la instalación Antes de instalar el generador FORCE W, es necesario limpiar a fondo el sistema, ya sea nuevo o existente, para eli- minar residuos de mecanizado, disolventes, lodos y contaminantes en general que puedan comprometer la eficacia de los tratamientos de protección.
  • Página 90 FORCE W Tabla 2- Acondicionadores químicos declarados idóneos y disponibles en nuestra red de centros de asistencia técnica autorizada. Productos alternativos tipo Senti- Descripción LIFE PLUS/B - MOLY - MOLY K Inhibidor de corrosión a base de molibdeno X100 LIFE DUE Reducción del ruido y antincrustante de mantenimiento X200 BIO KILL...
  • Página 91: Kits Opcionales

    FORCE W Kits opcionales A petición, se suministran los siguientes kits: cód. 042070X0 - KIT BOMBA DE CIRCULACIÓN DE ALTA EFICIENCIA - 7 m (A - fig. 37) cód. 042071X0 - KIT BOMBA DE CIRCULACIÓN DE ALTA EFICIENCIA - 10 m (A - fig. 37) cód.
  • Página 92: Ejemplos De Circuitos Hidráulicos

    FORCE W Ejemplos de circuitos hidráulicos En los ejemplos siguientes se indica la necesidad de MENU controlar/modificar algunos parámetros. Para ello, acceda al menú “Técnico”. USUARIO Desde la pantalla principal (Inicio), pulse la tecla Menú principal ( 12 - fig. 1). TECNICO Acceda al menú...
  • Página 93: Conexiones Eléctricas

    FORCE W Dos circuitos de calefacción directos - Esquema general fig. 42 - Conexiones eléctricas Una vez concluida la instalación, haga las conexiones eléctricas como se indica en el esquema correspondiente. A continuación, configure la centralita como se describe en el apartado correspondiente. Leyenda (fig.
  • Página 94: Parámetros

    FORCE W - Parámetros Cada aparato necesita una parametrización diferente. Proceda como se describe a continuación. Menú "Tipo instalación" Ajuste el parámetro P.01 del menú "Tipo instalación" a 4. - Funciones opcionales Además de las conexiones eléctricas de la figura anterior, necesarias para esta configuración de la instalación, existen opciones que no precisan ningún ajuste.
  • Página 95 FORCE W Un circuito de calefacción directo y un circuito de ACS con bomba de circulación - Esquema general fig. 45 - Conexiones eléctricas Una vez concluida la instalación, haga las conexiones eléctricas como se indica en el esquema correspondiente. A continuación, configure la centralita como se describe en el apartado correspondiente.
  • Página 96 FORCE W - Parámetros Cada aparato necesita una parametrización diferente. Proceda como se describe a continuación. Menú "Parámetros - Configuración” Controle/ajuste el parámetro b02 del menú "Parámetros modificables" a 8. Controle/ajuste el parámetro b08 del menú "Parámetros modificables" a 1. Controle/ajuste los parámetros b04, b05 y b06 del menú...
  • Página 97 FORCE W Un circuito de calefacción directo y un circuito de ACS con válvula desviadora (de 3 hilos) - Esquema general Utilice válvulas desviadoras de 3 hilos: - FASE DE APERTURA 230 V - FASE DE CIERRE 230 V - NEUTRO con tiempos de conmutación (de todo cerrado a todo abierto) no superiores a 90 s.
  • Página 98 FORCE W Leyenda (fig. 48 y fig. 49) Bomba de la calefacción Circuito del acumulador Termostato de ambiente 1ª zona (directa) 138 Sonda exterior Retorno 155 Sonda del acumulador K1 - K2bobina 230 Vca , < 2,2 VA 348 Válvula de 3 vías (3 hilos) contacto 230Vca , >...
  • Página 99 FORCE W Dos circuitos de calefacción mezclados, un circuito de calefacción directo y un circuito de AS con bomba de circulación - Esquema general La tarjeta de control de zonas FZ4B puede gestionar distintos tipos de instalación. El esquema presente es solo un ejemplo.
  • Página 100 FORCE W - Conexiones eléctricas Una vez concluida la instalación, haga las conexiones eléctricas como se indica en el esquema correspondiente. A continuación, configure la centralita como se describe en el apartado correspondiente. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 L _ N...
  • Página 101: A = Fase De Apertura

    FORCE W Leyenda (fig. 51 y fig. 52) 72a Termostato de ambiente 1ª zona (mezclada) B = NEUTRO 72b Termostato de ambiente 2ª zona (mezclada) C = FASE DE CIERRE 72c Termostato de ambiente 3ª zona (directa) 317a Termostato de seguridad 1ª zona (mezclada) 130 Bomba de circulación del acumulador 317b Termostato de seguridad 2ª...
  • Página 102: Conexión Del Gas

    FORCE W 2.4 Conexión del gas Antes de efectuar la conexión, controlar que el aparato esté preparado para fun- cionar con el tipo de combustible disponible y limpiar esmeradamente todos los tu- bos del gas para eliminar los residuos, que podrían perjudicar el funcionamiento de la caldera.
  • Página 103 FORCE W Sonda exterior (opcional) Conecte la sonda a los bornes correspondientes. El cable eléctrico utilizado para conectar la sonda exterior a la caldera no debe medir más de 50 m. Se puede usar un cable común de 2 conductores. La sonda exterior tiene que instalarse preferiblemente en una pared orientada al norte o noroeste, o en la pared correspondiente a la parte principal del salón.
  • Página 104: Para La Conexión En Cascada

    FORCE W Para la conexión en cascada NOTA: el sistema electrónico de la caldera puede controlar hasta seis módulos. 1. Conecte los módulos como se indica en la fig. 56 (ejemplo con 3 módulos). fig. 56 - Conexión en cascada A Primer módulo C Tercer módulo B Segundo módulo...
  • Página 105 FORCE W Generadores en cascada: un circuito de calefacción directo y un circuito de ACS con bomba de cir- culación Esquema general El sistema electrónico de la caldera puede controlar hasta seis módulos. En el ejemplo se ilustran tres. fig. 57 cod.
  • Página 106 FORCE W Conexiones eléctricas Una vez concluida la instalación, haga las conexiones eléctricas como se indica en el esquema correspondiente. A continuación, configure la centralita como se describe en el apartado correspondiente. 300M 300S 9 10 11 12 13 14 15 16 17 18 9 10 11 12 13 14 15 16 17 18 SLAVE 1 MASTER...
  • Página 107: Calefacción

    FORCE W Para el control de la temperatura adaptable es necesario adquirir la sonda exterior accesoria cód. 013018X0 Si se desea utilizar una sonda para el acumulador (no suministrada), es necesario adquirir la sonda NTC acce- soria cód. 1KWMA11W (2 m) o cód. 043005X0 (5 m). Si se desea utilizar un termostato para el acumulador (no suministrado), es necesario adquirir el kit accesorio cód.
  • Página 108: Conductos De Humos

    FORCE W 2.6 Conductos de humos LOS LOCALES DONDE SE INSTALEN LAS CALDERAS DEBEN CUMPLIR LOS REQUISITOS DE VENTILACIÓN FUNDAMENTALES. EN CASO CON- TRARIO, EXISTE PELIGRO DE ASFIXIA O INTOXICACIÓN. LEA LAS INSTRUCCIONES DE INSTALACIÓN Y MANTENIMIENTO ANTES DE INSTALAR EL APARATO. RESPETE TAMBIÉN LAS INSTRUCCIONES DE DISEÑO.
  • Página 109 FORCE W Tabla 4Tabla de accesorios MODELOS FORCE W 60 FORCE W 80 FORCE W 99 FORCE W 120 FORCE W 150 Presión de impulsión máxima permitida (Pa) TUBO 1 m M/H 11,9 24,5 TUBO 0,5 m M/H 12,3 Ø80 CODO 90°...
  • Página 110: Conexión De La Descarga De Condensado

    FORCE W Los tramos horizontales de salida de humos han de mantener una ligera pendiente hacia la caldera para evitar que la eventual condensación fluya al exterior y gotee. Antes de realizar el montaje, verifique con la tabla 5 que no se supere la longitud máxima permitida, considerando que cada codo coaxial provoca la reducción indicada en la tabla.
  • Página 111: Servicio Y Mantenimiento

    Todas las operaciones de regulación, transformación, puesta en servicio y mantenimiento que se describen a continuación deben ser efectuadas exclusivamente por un técnico autorizado, por ejemplo del Servicio de Asistencia local. FERROLI declina toda responsabilidad por daños materiales o personales derivados de la manipulación del aparato por personas que no estén debidamente autorizadas.
  • Página 112 FORCE W • Para modelos W 60 y W 80 Desenrosque los tornillos “B” y extraiga el grupo “Venturi/válvula del gas” (fig. 66). Desenrosque los tornillos “E” y sustituya el inyector de gas “F” por el que se incluye en el kit de cambio de gas, introduciéndolo en la junta “G”.
  • Página 113 FORCE W • Para los modelos W 99, W 120 y W 150 Extraiga la centralita de la válvula de gas (fig. 68). Desenrosque los tornillos “C” (fig. 69) que fijan el ventilador y extraiga el grupo (fig. 70). fig. 68 fig.
  • Página 114: Regulación Del Porcentaje De Co

    FORCE W • Para todos los modelos: Modifique el parámetro correspondiente al tipo de gas como se indica a continuación. Abra la pantalla ilustrada en la fig. 72 con la ruta "MENÚ DE USUARIO Mantenimiento Modo Test lección Tipo Gas". Pulse las teclas contextuales 1 y 2 para elegir el tipo de gas. Confirme con la tecla OK. Sélecion tipo Gas TECNICO para confirmar...
  • Página 115 FORCE W fig. 73- Regulación máxima modelos W 60 y W 80 fig. 74- Regulación mínimo modelos W 60 y W 80 fig. 75- Regulación máxima y mínima modelos W 99, W 120 y W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 116: Activación Del Modo Test

    FORCE W Activación del modo TEST Abra la pantalla ilustrada en la fig. 76 con la ruta "MENÚ USUARIO Mantenimiento Modo Test Modo Test”. La caldera se enciende y alcanza gradualmente la potencia máxima de calefacción (Range Rated) ajustada como se describe en el apartado siguiente.
  • Página 117: Menú Técnico

    FORCE W MENÚ TÉCNICO EL ACCESO AL MENÚ SERVICE Y LA MODIFICACIÓN DE LOS PARÁMETROS ESTÁN RESERVADOS AL PER- SONAL AUTORIZADO. El acceso al Menú Técnico exige la introducción del código 4 1 8. Es válido por 15 minutos. Menú Parámetros - Configuración Hay 16 parámetros, indicados con la letra "b", que no se pueden modificar con el cronomando a distancia.
  • Página 118 FORCE W Parámetro Descripción Campo W 60 W 80 W 99 W 120 W 150 Tiempo espera calefacción 0-10 minutos Poscirculación calefacción 0-255 minutos Funcionamiento de la bomba 0-3 Estrategia de funcionamiento Velocidad mínima bomba modulante 0-100 % Velocidad arranque bomba modulante 0-100 % Velocidad máxima bomba modulante 30-100 %...
  • Página 119: Menú Parámetros - Tipo Instalación

    FORCE W Menú Parámetros – Tipo Instalación Hay 23 parámetros, indicados con la letra "P.", que no se pueden modificar con el cronomando a distancia. Parámetro Descripción Campo W 60 W 80 W 99 W 120 W 150 0 = Demanda normal de calefacción 1 = Demanda de mando a distancia con habilitación on-off exterior 2 = Demanda señal 0 - 10 V con control en temperatura con...
  • Página 120: Puesta En Servicio

    FORCE W 3.2 Puesta en servicio Controles que se han de efectuar durante el primer encendido, tras las operacio- nes de mantenimiento que exijan desconectar la caldera y después de cualquier intervención en los dispositivos de seguridad o componentes de la caldera: Antes de encender la caldera •...
  • Página 121: Mantenimiento

    FORCE W 3.3 Mantenimiento ADVERTENCIAS TODAS LAS OPERACIONES DE MANTENIMIENTO Y SUSTITUCIÓN DEBEN SER REALIZADAS POR UN TÉCNICO AUTORIZADO. Antes de efectuar cualquier operación en el interior de la caldera, desconec- te la alimentación eléctrica y cierre la llave de paso del gas. De lo contrario, puede existir peligro de explosión, choque eléctrico, asfixia o intoxicación.
  • Página 122 FORCE W Apertura del panel frontal Algunos componentes internos de la caldera están a temperaturas muy altas y pueden causar quemaduras graves.Antes de hacer cualquier operación, espere a que dichos componentes se enfríen o colóquese guantes aislantes. Para abrir la cubierta de la caldera: 1.
  • Página 123 FORCE W Mantenimiento extraordinario y sustitución de componentes Sustitución del electrodo Limpieza del intercambiador cod. 3541V232 - Rev 00 - 08/2021...
  • Página 124: Solución De Problemas

    FORCE W 3.4 Solución de problemas Diagnóstico La caldera está dotada de un avanzado sistema de autodiagnóstico. Si se presenta una anomalía en la caldera, la pan- talla se enciende indicando el código de anomalía y, si se trata de una conexión en cascada, el número de módulo. •...
  • Página 125 FORCE W Código Anomalía Causa posible Solución anomalía Sensor averiado Anomalía en el sensor Cableado en cortocircuito Controlar el cableado o sustituir el sensor de calefacción 1 (ida) Cableado interrumpido Sensor averiado Anomalía del sensor de Cableado en cortocircuito Controlar el cableado o sustituir el sensor retorno Cableado interrumpido Sensor averiado...
  • Página 126: Características Y Datos Técnicos

    FORCE W 4. Características y datos técnicos Leyenda de las figuras cap. 4 Entrada de gas - Ø 3/4" Ida a calefacción - Ø 1” 1/2 Retorno de calefacción - Ø 1” 1/2 Válvula de seguridad Ventilador Bomba de la calefacción (no suministrada) Sensor temperatura calefacción Purgador de aire automático Válvula del gas...
  • Página 127: Medidas Y Conexiones

    FORCE W 4.1 Medidas y conexiones fig. 79- Vista frontal fig. 80- Vista lateral fig. 81- Vista superior fig. 82- Vista superior cod. 3541V232 - Rev 00 - 08/2021...
  • Página 128: Vista General

    4.2 Vista general fig. 84- Vista general mods. FORCE W 99 y FORCE W 120 fig. 83- Vista general mods. FORCE W 60 y FORCE W 80 fig. 85- Vista general mod. FORCE W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 129: Circuito Hidráulico

    FORCE W 4.3 Circuito hidráulico fig. 86- Circuito hidráulico cod. 3541V232 - Rev 00 - 08/2021...
  • Página 130: Tabla De Datos Técnicos

    FORCE W 4.4 Tabla de datos técnicos En la columna derecha se indica la abreviatura utilizada en la placa de datos técnicos. cod. 3541V232 - Rev 00 - 08/2021...
  • Página 131 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 132: Tablas Erp

    FORCE W 4.5 Tablas ErP cod. 3541V232 - Rev 00 - 08/2021...
  • Página 133 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 134 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 135 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 136 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 137: Diagramas

    4.6 Diagramas Pérdida de carga fig. 87- Diagrama de pérdida de carga modelos FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 fig. 88- Diagrama de pérdida de carga modelos FORCE W 150 Caudal - m...
  • Página 138: Esquemas Eléctricos

    FORCE W 4.7 Esquemas eléctricos La leyenda de las figuras está en page 126. ATENCIÓN: Antes de conectar el termostato ambiente o el cronomando a distancia, quite el puente de la caja de conexiones. ATENCIÓN: para conectar la válvula de tres vías (bornes 13 - 14 - 15), véanse los esquemas de fig. 89 y fig. 90. fig.
  • Página 139 FORCE W fig. 92- Esquema eléctrico modelos FORCE W 60 y FORCE W 80 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 140 FORCE W fig. 93- Esquema eléctrico modelos FORCE W 99, FORCE W 120 y FORCE W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 141: Advertencias Generales

    Esta garantía comercial es válida siempre que se realicen las operaciones normales de mantenimiento descritas en las Muchas gracias por elegir SILENT D eco 30 COND K 100 UNIT, una caldera de pie FERROLI instrucciones técnicas suministradas con los equipos.
  • Página 142 FORCE W • Citiţi cu atenţie avertizările din acest manual de in- • Acest aparat trebuie să fie destinat numai utilizării strucţiuni întrucât oferă indicaţii importante referitoa- pentru care a fost proiectat în mod expres. Orice altă re la siguranţa de instalare, utilizare şi întreţinere. utilizare este considerată...
  • Página 143 FORCE W 1 Instrucþiuni de utilizare....................... 144 1.1 Prezentare ............................144 1.2 Panoul de comandã ........................... 144 1.3 Pornirea ºi oprirea..........................148 1.4 Reglãrile ............................. 149 2 Instalarea ..........................157 2.1 Dispoziþii generale ..........................157 2.2 Locul de instalare ..........................157 2.3 Racordurile hidraulice.........................
  • Página 144: Instrucþiuni De Utilizare

    1.1 Prezentare Stimate Client, Vă mulţumim că aţi ales FORCE W, o centrală murală cu cameră etanşă FERROLI de concepţie avansată, tehnologie de avangardă, nivel ridicat de fiabilitate şi calitate constructivă. Vă rugăm să citiţi cu atenţie acest manual întrucât oferă...
  • Página 145 FORCE W Tastele directe Tastele directe (det. 8, 9, 10 - fig. 1) au întotdeauna aceeaşi funcţie. Tastele navigaţie/meniu Tastele navigaţie/meniu (det. 5, 6, 7, 11, 12, 13 - fig. 1) ajută la navigarea printre diferitele meniuri setate pe panoul de control.
  • Página 146 FORCE W ÎNTREŢINEREA Vezi fig. 76 Modul Test Selectarea tipului de Vezi fig. 72 Modul Test Modul Test Cascadă Vezi “Informaţii Service” on page 154 Informaţii Service Vezi “Dată intervenţie service” on page 154 Dată intervenţie service SETĂRI Vezi fig. 8 Limbă...
  • Página 147 FORCE W Excludere boiler (economy) Încălzirea/menţinerea temperaturii boilerului poate fi exclusă de către utilizator. În caz de excludere, nu se va produce apă caldă menajeră. Boilerul poate fi de- zactivat de către utilizator (modul ECO) apăsând pe tasta eco/comfort (det. 10 - fig. 1). În modul ECO, pe 23°C 32°C afişaj se activează...
  • Página 148: Pornirea ºi Oprirea

    FORCE W 1.3 Pornirea şi oprirea Pornirea centralei Apăsaţi pe tasta de aprindere/stingere (det. 14 - fig. 1). Apăsând pe tasta contextuală 1 puteţi alege limba do- rită şi o puteţi confirma cu ajutorul tastei „OK”. Apăsând pe tasta contextuală 3 puteţi întrerupe modul Dacă...
  • Página 149: Reglãrile

    FORCE W Oprirea centralei De pe ecranul principal/Home, apăsaţi tasta contex- tuală şi confirmaţi cu tasta Când centrala este oprită, cartela electronică mai este încă alimentată cu energie electrică. E dezactivată funcţionarea circuitului de apă caldă menajeră (cu boiler opţional instalat) şi a circuitului de încălzire.
  • Página 150 FORCE W Reducerea temperaturii de încălzire Accesaţi meniul „Temp. de reglare reducere” pentru CH setpoint reduction a modifica temperatura de la un minim de 0°C la un maxim de 50°. Confirmaţi cu tasta OK. Acest parametru este utilizat numai dacă este activată...
  • Página 151 FORCE W Selectaţi ziua (fig. 17) sau intervalul de zile care trebuie programate (fig. 18) şi confirmaţi cu tasta OK. Scheduler Set Scheduler Set Wednesday Monday Thursday Tuesday Friday Wednesday Saturday Thursday Sunday Friday Monday-Sunday Saturday Monday-Friday Sunday Saturday-Sunday Monday-Sunday to confirm to confirm fig.
  • Página 152 FORCE W Apăsaţi tasta de navigaţie 7 şi utilizaţi tastele contex- Scheduler Set tuale 1 şi 2 pentru a seta modul de funcţionare în tim- pul primului interval orar (fig. 21) 06:00 - 16:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:--...
  • Página 153 FORCE W Pentru a readuce programarea orarului la Scheduler Set valorile din fabricaţie, apăsaţi tasta contex- tuală 3 din meniul Scheduler set (fig. 26) şi Monday confirmaţi cu OK. Tuesday Wednesdey Thursday Friday Saturday Sunday Monday-Sunday to confirm fig. 26 Cele două...
  • Página 154 FORCE W Funcţia Vacanţă Accesaţi meniul „FUNCŢIA VACANŢĂ” urmând calea „MENIU USER „FUNCŢIA VACANŢĂ” pentru a putea seta: • Data de începere a vacanţei. • Data de terminare a vacanţei. Pe afişaj se pot activa două tipuri de pictograme: • - Funcţia Vacanţă...
  • Página 155 FORCE W Reglaţi deplasarea paralelă a curbelor de la 20 la OTC Offset 1 60°C (fig. 31), cu ajutorul parametrului „Offset1”, şi confirmaţi cu tasta OK. to confirm fig. 29- Deplasarea paralelă a curbelor Dacă temperatura ambiantă e mai mică faţă de valoarea dorită, se recomandă să selectaţi o curbă de ordin superior şi invers.
  • Página 156 FORCE W Reglările de la cronocomanda la distanţă Dacă la centrală este conectată Cronocomanda la distanţă (opţional), reglările de mai sus trebuie efectuate conform indicaţiilor din tabel 1. Tabel 1 Reglarea temperaturii în circuitul de Reglarea poate fi efectuată fie din meniul Cronocomenzii la distanţă, fie de la panoul de încălzire comandă...
  • Página 157: Instalarea

    FORCE W 2. Instalarea 2.1 Dispoziţii generale INSTALAREA CENTRALEI TREBUIE EFECTUATĂ NUMAI DE PERSONAL SPECIALIZAT ŞI CU CALIFICARE RE- CUNOSCUTĂ, RESPECTÂNDU-SE TOATE INSTRUCŢIUNILE MENŢIONATE ÎN PREZENTUL MANUAL TEHNIC, DISPOZIŢIILE LEGALE ÎN VIGOARE, CERINŢELE NORMELOR NAŢIONALE ŞI LOCALE ŞI CONFORM REGULI- LOR DE BUNĂ...
  • Página 158 FORCE W Pompă de circulaţie cu eficienţă ridicată (opţional) Setarea din fabricaţie este adecvată pentru toate tipurile de instalare; cu toate acestea, este posibil să se seteze, cu ajutorul selectorului de viteză (vezi fig. 33), o strategie de funcţionare diferită, în funcţie de caracteristicile instalaţiei. 1 2 3 fig.
  • Página 159 FORCE W Caracteristicile apei din instalaţie Înainte de a începe instalarea generatorului FORCE W, instalaţia, nouă sau existentă, trebuie să fie curăţată corespun- zător, pentru a elimina reziduurile de la instalare, solvenţii, nămolurile şi contaminanţii în general care ar putea reduce eficienţa tratamentelor cu substanţe chimice de protecţie.
  • Página 160 FORCE W Tabel 2- Produse chimice de tratare declarate adecvate şi disponibile în reţeaua noastră de Centre de Asistenţă Tehnică Autorizată Descriere Produse alternative de tip Sentinel LIFE PLUS/B - MOLY - MOLY K Inhibitor de coroziune pe bază de molibden X100 LIFE DUE Reducerea zgomotului/inhibitor de depuneri de întreţinere...
  • Página 161 FORCE W Kituri opţionale La cerere sunt disponibile următoarele kituri: cod 042070X0 - KIT POMPĂ DE CIRCULAŢIE cu EFICIENŢĂ RIDICATĂ - 7 m. (A - fig. 37) cod 042071X0 - KIT POMPĂ DE CIRCULAŢIE cu EFICIENŢĂ RIDICATĂ - 10 m. (A - fig. 37) cod 042072X0 - KIT HIDRAULIC În Kit 042072X0 se află: VALVĂ...
  • Página 162 FORCE W Exemple circuite hidraulice În exemplele descrise mai jos poate fi necesar să se MENU verifice/modifice unii parametri. Pentru a face acest lucru este necesar să se acceseze USER meniul Technician. De pe ecranul principal (Home), apăsaţi tasta Meniu principal (det.
  • Página 163: Conexiuni Electrice

    FORCE W Două circuite de încălzire directe - Schemă de principiu fig. 42 - Conexiuni electrice După instalare va fi necesar să se efectueze conexiunile electrice necesare, aşa cum se arată în schema electrică. După aceea, treceţi la configurarea unităţii de comandă, după cum se arată în paragraful respectiv. Legendă...
  • Página 164 FORCE W - Parametri Fiecare instalaţie necesită o configurare diferită a parametrilor. Urmaţi procedura de acces indicată mai jos. „System Type Menu” Modificaţi parametrul P.01 din „System Type Menu” la 4. - Funcţii opţionale Pe lângă conexiunile electrice din figura anterioară (necesare pentru această configuraţie a instalaţiei) există şi opţiuni care nu necesită...
  • Página 165 FORCE W Un circuit de încălzire direct şi un circuit de apă menajeră cu pompă de circulaţie - Schemă de principiu fig. 45 - Conexiuni electrice După instalare va fi necesar să se efectueze conexiunile electrice necesare, aşa cum se arată în schema electrică. După...
  • Página 166 FORCE W - Parametri Fiecare instalaţie necesită o configurare diferită a parametrilor. Urmaţi procedura de acces indicată mai jos. „Configuration - Parameters Menu” Verificaţi/Modificaţi parametrul b02 din „Meniul Parametri Transparenţi” la 8. Verificaţi/Modificaţi parametrul b08 din „Meniul Parametri Transparenţi” la 1. Verificaţi/Modificaţi parametrii b04, b05 şi b06 din “Meniul Parametri Transparenţi”...
  • Página 167 FORCE W Un circuit de încălzire direct şi un circuit de apă menajeră cu valvă deviatoare (cu 3 fire) - Schemă de principiu Utilizaţi valve deviatoare cu 3 fire: - FAZA DE DESCHIDERE 230 V - FAZA DE ÎNCHIDERE 230 V = NEUTRU cu timpi de comutare (de la complet închis la complet deschis) nu mai mari de 90 secunde.
  • Página 168 FORCE W Legendă (fig. 48 şi fig. 49) Pompă de circulaie încălzire Circuit boiler Termostat de cameră zona 1 (directă) 138 Sondă externă Retur 155 Sondă boiler K1 - K2bobina 230 V c.a., < 2,2 VA 348 Valvă cu 3 căi (cu trei fire) contact 230 V c.a., >...
  • Página 169 FORCE W Două circuite de încălzire mixte, un circuit de încălzire direct şi un circuit de apă menajeră cu pompă de circulaţie - Schemă de principiu Cartela pentru controlul pe zone FZ4B poate controla diferite tipuri de instalaţii. Aici este prezentat un exemplu. Utilizaţi valve deviatoare cu 3 fire: - FAZA DE DESCHIDERE 230 V - FAZA DE ÎNCHIDERE 230 V...
  • Página 170 FORCE W - Conexiuni electrice După instalare va fi necesar să se efectueze conexiunile electrice necesare, aşa cum se arată în schema electrică. După aceea, treceţi la configurarea unităţii de comandă, după cum se arată în paragraful respectiv. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 L _ N...
  • Página 171: C = Faza De Închidere

    FORCE W Legendă (fig. 51 şi fig. 52) 72a Termostat de cameră zona 1 (mixtă) C = FAZA DE ÎNCHIDERE 72b Termostat de cameră zona a 2-a (mixtă) 317a Termostat de siguranţă zona 1 (mixtă) 72c Termostat de cameră zona a 3-a (directă) 317b Termostat de siguranţă...
  • Página 172: Racordarea La Gaz

    FORCE W 2.4 Racordarea la gaz Înainte de efectuarea racordării, verificaţi ca aparatul să fie proiectat pentru funcţionarea cu tipul de combustibil disponibil şi efectuaţi o curăţare corectă a tu- turor ţevilor de gaz ale instalaţiei, pentru a îndepărta eventualele reziduuri care ar putea compromite buna funcţionare a centralei.
  • Página 173: Accesul La Panoul De Borne Electric

    FORCE W Sondă externă (opţională) Conectaţi sonda la bornele corespunzătoare Lungimea maximă permisă a cablului electric de conectare centrală - son- dă externă este de 50 m. Se poate utiliza un cablu normal cu 2 conductori. Sonda externă trebuie instalată de preferat pe peretele dinspre nord, nord-vest, sau pe cel pe care se află...
  • Página 174 FORCE W Pentru montarea în sistem cascadă NOTĂ: cartela electronică a centralei poate gestiona maximum 6 module. 1. Conectaţi modulele aşa cum se arată în fig. 56 (exemplu cu 3 module) fig. 56- Conectare în cascadă A Primul modul C Al 3-lea modul B Al 2-lea modul 2.
  • Página 175 FORCE W Generatoare conectate în cascadă: un circuit de încălzire direct şi un circuit de apă menajeră cu pompă de circulaţie Schemă de principiu Cartela electronică a centralei poate gestiona maximum 6 module. În acest exemplu sunt prezentate 3. fig. 57 cod.
  • Página 176 FORCE W Conexiunile electrice După instalare va fi necesar să se efectueze conexiunile electrice necesare, aşa cum se arată în schema electrică. După aceea, treceţi la configurarea unităţii de comandă, după cum se arată în paragraful respectiv. 300M 300S 9 10 11 12 13 14 15 16 17 18 9 10 11 12 13 14 15 16 17 18 SLAVE 1 MASTER...
  • Página 177 FORCE W Pentru a controla temperatura variabilă trebuie să achiziţionaţi sonda externă accesorie, cod 013018X0 În cazul utilizării unei sonde pentru boiler (nu este furnizată), este necesar să achiziţionaţi sonda NTC acceso- rie, cod 1KWMA11W (2 mt.) sau cod 043005X0 (5 mt.) În cazul utilizării unui termostat pentru boiler (nu este furnizat), este necesar să...
  • Página 178: Conductele Pentru Gaze Arse

    FORCE W 2.6 Conductele pentru gaze arse CENTRALELE TREBUIE SĂ FIE INSTALATE ÎN ÎNCĂPERI CARE CORE- SPUND CERINŢELOR DE VENTILAŢIE FUNDAMENTALE. ÎN CAZ CONTRAR EXISTĂ PERICOLUL DE ASFIXIE SAU DE INTOXICARE. CITIŢI INSTRUCŢIUNILE DE INSTALARE ŞI DE ÎNTREŢINERE ÎNAINTE DE A INSTALA APARATUL.
  • Página 179 FORCE W Tabel 4Tabel accesorii MODELE FORCE W 60 FORCE W 80 FORCE W 99 FORCE W 120 FORCE W 150 Înălţimea de pompare maximă permisă (Pa) TUB 1 M tată/mamă 11,9 16,0 24,5 TUB 0,5 M tată/mamă 12,3 Ø80 COT 90°...
  • Página 180: Racordarea Evacuãrii Condensului

    FORCE W Este necesar ca eventualele porţiuni orizontale ale conductelor de evacuare a gazelor arse să aibă o uşoară înclinare către centrală, pentru a evita ca eventualul condens să se scurgă spre exterior şi să picure. Înainte de a trece la instalare, verificaţi cu ajutorul tabel 5 să nu se depăşească lungimea maximă permisă, ţinând cont de faptul că...
  • Página 181: Exploatarea I Întreinerea

    Personal Calificat şi cu o calificare atestată (în posesia cerinţelor tehnice profesionale prevăzute de normele în vigoare), ca, de ex., personalul de la Serviciul Tehnic de Asistenţă Clienţi din zonă. FERROLI îşi declină orice responsabilitate pentru pagubele produse bunurilor şi/sau persoanelor ca urmare a intervenţiilor efectuate asupra aparatului de persoane necalificate şi neautorizate.
  • Página 182 FORCE W • Pentru modelele W 60 şi W 80 Deşurubaţi şuruburile „B” şi scoateţi ansamblul “Venturi/valvă de gaz” (fig. 66). Deşurubaţi şuruburile „E” şi apoi înlocuiţi duza de gaz „F” cu cea aflată în kitul de transformare, poziţionând-o în interiorul garniturii „G”.
  • Página 183 FORCE W • Pentru Modelele W 99, W 120 şi W 150 Scoateţi unitatea de comandă din valva de gaz (fig. 68). Deşurubaţi şuruburile „C” (fig. 69) care fixează ventilatorul şi scoateţi ansamblul (fig. 70). fig. 68 fig. 69 Deşurubaţi şuruburile „E” şi apoi înlocuiţi duza de gaz „F” cu cea aflată în kitul de transformare, poziţionând-o în interiorul garniturii „G”.
  • Página 184 FORCE W • Pentru toate modelele Modificaţi parametrul referitor la tipul de gaz, aşa cum se arată în continuare. Duceţi-vă la ecranul prezentat în fig. 72 navigând în meniu, urmând calea „MENIU USER Întreţinerea Modul Test Gas Type”. Apăsaţi tastele contextuale 1 şi 2 pentru a alege tipul de gaz. Confirmaţi cu tasta OK. Gas Type TECNICO to confirm...
  • Página 185 FORCE W fig. 73- Reglarea maximă la modelele W 60 i W 80 fig. 74- Reglarea minimă la modelele W 60 i W 80 fig. 75- Reglarea maximă i minimă la modelele W 99, W 120 i W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 186 FORCE W Activarea modului TEST Duceţi-vă la ecranul prezentat în fig. 76 navigând în meniu, urmând calea „MENIU USER Întreţinerea Modul Test Installer Test Mode”. Centrala se aprinde, atingând puterea maximă de încălzire (Range Rated), reglată conform paragrafului următor, în mod treptat.
  • Página 187 FORCE W MENIUL TECHNICIAN ACCESUL LA MENIUL SERVICE ŞI MODIFICAREA PARAMETRILOR POT FI EFECTUATE NUMAI DE PERSO- NAL CALIFICAT. Accesul la Meniul Technician este posibil numai după ce aţi introdus codul 4 1 8. Şi este valabil timp de 15 minute. Meniul Parametri - Configurare Sunt disponibili 16 parametri indicaţi cu litera „b”, care nu pot fi modificaţi de la Cronocomanda la distanţă.
  • Página 188 FORCE W Parametru Descriere Interval W 60 W 80 W 99 W 120 W 150 Temperatură minimă setpoint virtual 20-80°C Interval aşteptare încălzire 0-10 minute Post-circulaţie încălzire 0-255 minute Funcţionare pompă 0-3 Strategie de funcţionare Viteză minimă pompă modulantă 0-100% Viteză...
  • Página 189 FORCE W Meniul Parametri - Tipul instalaţiei Sunt disponibili 23 parametri indicaţi cu litera „P.”, care nu pot fi modificaţi de la Cronocomanda la distanţă. Parametru Descriere Interval W 60 W 80 W 99 W 120 W 150 0 = Cerere normală de încălzire 1 = Cerere de la comanda la distanţă, cu activare on-off externă...
  • Página 190: Punerea În Funcþiune

    FORCE W 3.2 Punerea în funcţiune Verificări care trebuie efectuate la prima pornire şi după toate operaţiile de în- treţinere care au impus deconectarea de la instalaţii sau o intervenţie la dispoziti- vele de siguranţă sau la părţi ale centralei: Înainte de pornirea centralei •...
  • Página 191: Întreþinerea

    FORCE W 3.3 Întreţinerea AVERTIZĂRI TOATE OPERAţIILE DE ÎNTREţINERE şI DE ÎNLOCUIRE TREBUIE EFECTUA- TE DE PERSONAL CALIFICAT şI CU O CALIFICARE ATESTATĂ. Înainte de efectuarea oricărei operaţiuni în interiorul centralei, întrerupeţi ali- mentarea cu energie electrică şi închideţi robinetul de gaz din amonte. În caz contrar poate să...
  • Página 192 FORCE W Deschiderea panoului frontal Unele componente interne ale centralei pot atinge temperaturi ridicate, care pot provoca arsuri grave.Înainte de a efectua orice operaţie, aşteptaţi ca ace- ste componente să se răcească sau, ca alternativă, purtaţi mănuşi adecvate. Pentru a deschide carcasa centralei: 1.
  • Página 193 FORCE W Întreţinerea extraordinară şi înlocuirea componentelor Înlocuirea electrodului Curăţarea schimbătorului de căldură cod. 3541V232 - Rev 00 - 08/2021...
  • Página 194: Rezolvarea Problemelor

    FORCE W 3.4 Rezolvarea problemelor Diagnosticarea Centrala este dotată cu un sistem avansat de autodiagnosticare. În cazul apariţiei unei anomalii la centrală, afişajul se aprinde, indicând codul anomaliei şi, în cazul conectării în cascadă, numărul modulului. • Există anomalii care cauzează blocări permanente, care pot fi resetate apăsând pe tasta OK timp de o secundă sau cu ajutorul tastei RESET de pe cronocomanda la distanţă...
  • Página 195 FORCE W Anomalie Cauză posibilă Soluţie anomalie Senzor defect Anomalie senzor retur Cablaj în scurtcircuit Verificaţi cablajul sau înlocuiţi senzorul Cablaj întrerupt Senzor defect Anomalie senzor apă Cablaj în scurtcircuit Verificaţi cablajul sau înlocuiţi senzorul caldă menajeră Cablaj întrerupt Senzor defect Anomalie senzor gaze Cablaj în scurtcircuit Verificaţi cablajul sau înlocuiţi senzorul...
  • Página 196: Caracteristici I Date Tehnice

    FORCE W 4. Caracteristici i date tehnice Legendă figuri cap. 4 "Caracteristici i date tehnice" Intrare gaz - Ø 3/4” Tur instalaţie - Ø 1” 1/2 Retur instalaţie - Ø 1” 1/2 Supapă de siguranţă Ventilator Pompă de circulaţie încălzire (nu este furnizată) Senzor temperatură...
  • Página 197: Dimensiuni ºi Racorduri

    FORCE W 4.1 Dimensiuni şi racorduri fig. 79- Vedere frontală fig. 80- Vedere laterală fig. 81- Vedere de sus fig. 82- Vedere de sus cod. 3541V232 - Rev 00 - 08/2021...
  • Página 198: Vedere Generalã

    4.2 Vedere generală fig. 84- Vedere generală mod. FORCE W 99 şi FORCE W 120 fig. 83- Vedere generală mod. FORCE W 60 şi FORCE W 80 fig. 85- Vedere generală mod. FORCE W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 199: Circuitul Hidraulic

    FORCE W 4.3 Circuitul hidraulic fig. 86- Circuitul hidraulic cod. 3541V232 - Rev 00 - 08/2021...
  • Página 200: Tabel Cu Datele Tehnice

    FORCE W 4.4 Tabel cu datele tehnice În coloana din dreapta este indicată abrevierea utilizată pe plăcuţa cu datele tehnice. cod. 3541V232 - Rev 00 - 08/2021...
  • Página 201 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 202: Tabele Erp

    FORCE W 4.5 Tabele ErP cod. 3541V232 - Rev 00 - 08/2021...
  • Página 203 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 204 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 205 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 206 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 207: Diagrame

    4.6 Diagrame Pierdere de sarcină fig. 87- Diagramă pierderi de sarcină modelele FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 fig. 88- Diagramă pierderi de sarcină modelele FORCE W 150 Debit - m...
  • Página 208: Scheme Electrice

    FORCE W 4.7 Scheme electrice Legenda figurilor se găseşte la page 196. ATENŢIE: Înainte de a racorda termostatul de cameră sau cronocomanda la distanţă, scoateţi puntea de pe pa- noul de borne. ATENŢIE: pentru racordarea valvei cu 3 căi (bornele 13 - 14 - 15), consultaţi schemele din fig. 89 şi fig. 90. fig.
  • Página 209 FORCE W fig. 92- Schemă electrică modelele FORCE W 60 şi FORCE W 80 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 210 FORCE W fig. 93- Schemă electrică modelele FORCE W 99, FORCE W 120 şi FORCE W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 211 FORCE W • Read the warnings in this instruction booklet carefu- • The unit can be used by children aged at least 8 lly since they provide important information on safe years and by persons with reduced physical, sen- installation, use and maintenance. sory or mental capabilities, or lacking experience or •...
  • Página 212 FORCE W 1 Operating instructions ......................213 1.1 Introduction............................213 1.2 Control panel ............................213 1.3 Lighting and shutdown ........................217 1.4 Adjustments............................218 2 Installation ..........................226 2.1 General Instructions ........................... 226 2.2 Place of installation ..........................226 2.3 Plumbing connections ........................226 2.4 Gas connection ..........................
  • Página 213: Thursday 9 Jan. 2014 00:15:60

    FORCE W 1. Operating instructions 1.1 Introduction Dear Customer, Thank you for choosing FORCE W, a wall-mounted sealed chamberFERROLI boiler featuring advanced design, cut- ting-edge technology, high reliability and quality construction. Please read this manual carefully, as it provides important information on safe installation, use and maintenance.
  • Página 214: Menu Structure

    FORCE W Direct buttons The direct buttons (details 8, 9, 10 - fig. 1) always have the same function. Menu/navigation buttons The menu/navigation buttons (details 5, 6, 7, 11, 12, 13 - fig. 1) are used to navigate among the various menus imple- mented in the control panel.
  • Página 215: 23°C 32°C

    FORCE W MAINTENANCE See fig. 76 Test Mode See fig. 72 Test Mode Gas Type Selection Cascade Test Mode See “Service Information” on page 223 Service Information See “Service Intervention Date” on page 223 Service Intervention Date SETTINGS See fig. 8 Language Unit of measure See fig.
  • Página 216: Thursday 9 Jan. 2014 11:30:43

    FORCE W Exclude hot water tank (economy) Hot water tank temperature maintaining/heating can be excluded by the user. If excluded, domestic hot wa- ter will not be delivered. The hot water tank can be de- activated by the user (ECO mode) by pressing the eco/comfort button (detail 10 - fig.
  • Página 217: Lighting And Shutdown

    FORCE W 1.3 Lighting and shutdown Boiler lighting Press the On/Off button (detail 14 - fig. 1). By pressing contextual button 1 it is possible to choose the desired language and confirm it with the “OK” button. By pressing contextual button 3 it is possible to inter- rupt the FH mode.
  • Página 218: Thursday 9 Jan. 2014 00:15:60

    FORCE W Boiler shutdown From the main screen/Home, press the contextual button and confirm with the button When the boiler is turned off, the PCB is still powered. Domestic hot water (with optional hot water tank in- stalled) and heating operation are disabled. The frost protection system remains on.
  • Página 219 FORCE W Heating temperature reduction Access the “Reduction Adjustment Temp” menu to CH setpoint reduction vary the temperature from a minimum of 0°C to a max- imum of 50°. Confirm with the OK button. This parameter is used only if time program- ming is activated.
  • Página 220 FORCE W Select the day (fig. 17) or the interval of days to program (fig. 18) and confirm with the OK button. Scheduler Set Scheduler Set Monday Wednesday Thursday Tuesday Friday Wednesday Saturday Thursday Sunday Friday Monday-Sunday Saturday Monday-Friday Sunday Saturday-Sunday Monday-Sunday to confirm...
  • Página 221 FORCE W Press navigation button 7 and use contextual buttons Scheduler Set 1 and 2 to set the work mode during the first time band (fig. 21) 06:00 - 16:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- Copy to the Next Day Save &...
  • Página 222 FORCE W To restore the time program to the factory Scheduler Set values, press contextual button 3 in the Time Program menu (fig. 26) and confirm Monday with OK. Tuesday Wednesdey Thursday Friday Saturday Sunday Monday-Sunday to confirm fig. 26 The two Heating and DHW hourly programs are independent even in case of Reset to factory value.
  • Página 223: Holiday Function

    FORCE W Holiday Function Access the "HOLIDAY FUNCTION" menu through the path "USER MENU “HOLIDAY FUNCTION” to set: • Holiday start date. • Holiday end date. The display can activate two types of icons: • - The Holiday function is programmed but not yet active. •...
  • Página 224 FORCE W Adjust the parallel offset of the curves from 20 to 60 °C OTC Offset 1 (fig. 31), via the parameter “Offset1” and confirm with the OK button. to confirm fig. 29- Parallel curve offset If the room temperature is lower than the desired value, it is advisable to set a higher order curve and vice versa. Pro- ceed by increasing or decreasing in steps of one and check the result in the room.
  • Página 225 FORCE W Adjustments from remote timer control If the boiler is connected to the Remote Timer Control (optional), the previously described adjustments are managed as described in table 1. Table 1 Heating temperature adjustment Adjustment can be made from the Remote Timer Control menu and the boiler control panel. DHW temperature adjustment (with Adjustment can be made from the Remote Timer Control menu and the boiler control panel.
  • Página 226: Installation

    FORCE W 2. Installation 2.1 General Instructions BOILER INSTALLATION MUST ONLY BE PERFORMED BY QUALIFIED PERSONNEL, IN ACCORDANCE WITH ALL THE INSTRUCTIONS GIVEN IN THIS TECHNICAL MANUAL, THE PROVISIONS OF CURRENT LAW, THE PRE- SCRIPTIONS OF NATIONAL AND LOCAL STANDARDS AND THE RULES OF PROPER WORKMANSHIP. 2.2 Place of installation The generator must be installed in a suitable room with ventilation openings towards the outside in conformity with cur- rent regulations.
  • Página 227 FORCE W High-efficiency circulating pump (optional) The factory setting is suitable for all installations; however a different operation strategy can be set with the speed se- lector (see fig. 33), depending on the characteristics of the system. 1 2 3 fig.
  • Página 228: System Water Characteristics

    FORCE W System water characteristics Before installing the FORCE W generator, the new or existing system must be properly cleaned in order to eliminate installation residues, solvents, sludge and contaminants in general that may compromise the effectiveness of the pro- tective conditioning treatments.
  • Página 229 FORCE W Table 2- Chemical conditioners declared suitable and available at our network of Authorized Tech- nical Assistance Centers Description Sentinel type alternative products LIFE PLUS/B - MOLY - MOLY K Molybdenum-based corrosion inhibitor X100 LIFE DUE Noise reduction/anti-scaling maintenance X200 BIO KILL Biocidal anti-algae...
  • Página 230: Optional Kits

    FORCE W Optional kits The following kits are available on request: code 042070X0 - HIGH EFFICIENCY CIRCULATING PUMP KIT- 7m. (A - fig. 37) code 042071X0 - HIGH EFFICIENCY CIRCULATING PUMP KIT- 10m. (A - fig. 37) code 042072X0 - PLUMBING KIT The Kit 042072X0 contains: NON-RETURN VALVE - Female 1”1/2 (B - fig.
  • Página 231 FORCE W Hydraulic circuit examples In the examples described below, the checking/ MENU change of some parameters may be required. To do this it is necessary to access the Technical USER menu. From the Home page, press the main Menu button TECHNICIAN (detail 12 - fig.
  • Página 232: Electrical Connections

    FORCE W Two direct heating circuits - Schematic diagram fig. 42 - Electrical connections After installation, carry out the necessary electrical connections as shown in the wiring diagram. Then configure the controller as described in the specific section. Legend (fig. 42 and fig. 43) 9 10 11 12 13 14 15 16 17 18 1st zone (direct) room thermostat 72b 2nd zone (direct) room thermostat...
  • Página 233: Optional Features

    FORCE W - Parameters Each system requires a different parameterization. Follow the access procedure given below. “System Type Menu” Change parameter P.01 of the “System Type Menu” to 4. - Optional features In addition to the electrical connections of the previous figure (necessary for this system configuration) there are options that do not require settings.
  • Página 234 FORCE W One direct heating circuit and one DHW circuit with circulating pump - Schematic diagram fig. 45 - Electrical connections After installation, carry out the necessary electrical connections as shown in the wiring diagram. Then configure the controller as described in the specific section. Legend (fig.
  • Página 235 FORCE W - Parameters Each system requires a different parameterization. Follow the access procedure given below. “Configuration - Parameters Menu” Check/Change parameter b02 of the “Transparent Parameters Menu” to 8. Check/Change parameter b08 of the “Transparent Parameters Menu” to 1. Check/Change parameter b04, b05 and b06 of the "Transparent Parameter Menu"...
  • Página 236 FORCE W A direct heating circuit and a DHW circuit with diverter valve (3-wire) - Schematic diagram Use diverter valves with 3 wires: - 230V OPENING PHASE - 230V CLOSING PHASE - NEUTRAL with switching times (from all closed to all open) of not more than 90 seconds. fig.
  • Página 237 FORCE W Legend (fig. 48 and fig. 49) Heating circulating pump Hot water tank circuit 1st zone (direct) room thermostat Flow 138 External probe Return 155 Hot water tank probe K1 - K2coil 230 Vac, <2.2 VA 348 3-way valve (3-wire) contact 230Vac, >...
  • Página 238 FORCE W Two mixed heating circuits, one direct heating circuit and one DHW circuit with circulating pump - Schematic diagram The zone control card FZ4B can manage different types of systems. An example is given. Use diverter valves with 3 wires: - 230V OPENING PHASE - 230V CLOSING PHASE - NEUTRAL...
  • Página 239 FORCE W - Electrical connections After installation, carry out the necessary electrical connections as shown in the wiring diagram. Then configure the controller as described in the specific section. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 L _ N L _ N L _ N...
  • Página 240 FORCE W Legend (fig. 51 and fig. 52) 72a 1st zone (mixed) room thermostat B = NEUTRAL 72b 2nd zone (mixed) room thermostat C = CLOSING PHASE 72c 3rd zone (direct) room thermostat 317a 1st zone (mixed) safety thermostat 130 Hot water tank circulating pump 317b 2nd zone (mixed) safety thermostat 138 External probe 318a 1st zone (mixed) circulating pump...
  • Página 241: Gas Connection

    FORCE W 2.4 Gas connection Before carrying out the connection, make sure the unit is arranged for operation with the type of fuel available and carefully clean all the pipes of the gas system to remove any residues that could affect proper boiler operation. The gas must be connected to the relevant connection (see fig.
  • Página 242 FORCE W External probe (optional) Connect the probe to its respective terminals. The maximum permissible length of the boiler – external probe connection electric cable is 50 m. A common 2-core cable can be used. The external probe should preferably be installed on the North, North-West wall or on the wall with most of the main living room.
  • Página 243: Possible Faults

    FORCE W For cascade connection NOTE: The boiler’s electronics can manage up to a maximum of 6 modules. 1. Connect the modules as shown in fig. 56 (example with 3 modules) fig. 56 - Connection in cascade A 1st Module C 3rd Module B 2nd Module 2.
  • Página 244 FORCE W Generators in cascade: a direct heating circuit and a DHW circuit with circulating pump Schematic diagram The boiler electronics can manage up to a maximum of 6 modules. 3 are given in the example. fig. 57 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 245 FORCE W Electrical connections After installation, carry out the necessary electrical connections as shown in the wiring diagram. Then configure the controller as described in the specific section. 300M 300S 9 10 11 12 13 14 15 16 17 18 9 10 11 12 13 14 15 16 17 18 SLAVE 1 MASTER...
  • Página 246 357 Fault indication (230Vac): the example shows the connection of a 230Vac lamp “For further cascade, hydraulic and electrical connection diagrams, please consult the website www.ferroli.com in the section dedicated to RESIDENTIAL products, Boilers, FORCE W and, under MANUALS, download the technical doc-...
  • Página 247: Fume Ducts

    FORCE W 2.6 Fume ducts THE BOILERS MUST BE INSTALLED IN ROOMS THAT MEET THE FUNDA- MENTAL VENTILATION REQUIREMENTS. OTHERWISE THERE IS A DAN- GER OF ASPHYXIA OR POISONING. READ THE INSTALLATION AND MAINTENANCE INSTRUCTIONS BEFORE INSTALLING THE UNIT. ALSO RESPECT THE DESIGN INSTRUCTIONS. IN CASE OF PRESSURES EXCEEDING 200 Pa INSIDE THE FUME EXHAUST PIPES, THE USE OF CLASS "H1”...
  • Página 248 TERMINAL Calculation examples FORCE W 60: available head 77 Pa 5 meters PIPE Ø80 + 3 BENDS Ø80 = (5 x 4.8) + (3 x 10)= 55<77 = OK 8 meters PIPE Ø80 + 6 CURVE Ø80 = (8 x 4.8) + (6 x 10)= 100>77 = NO Fume ducts If installation of the unit is “type C13 or C33”...
  • Página 249: Condensate Drain Connection

    FORCE W Any horizontal sections of the fume exhaust must be kept sloping slightly towards the boiler, to prevent possible con- densate from flowing back towards the outside and causing dripping. Before proceeding with installation, check with table 5 that the maximum permissible length is not exceeded, bearing in mind that every coaxial bend gives rise to the reduction indicated in the table.
  • Página 250: Service And Maintenance

    Personnel (meeting the professional technical requirements of current regulations) such as the personnel of the Local After-Sales Technical Service. FERROLI declines any liability for damage and/or injury caused by unqualified and unauthorized persons tampering with the unit. 3.1 Adjustments Gas conversion The unit can work with natural gas or LPG.
  • Página 251 FORCE W • For models W 60 and W 80 Undo the screws “B” and remove the “Venturi/gas valve” (fig. 66) unit. Undo the screws “E” and then replace the gas nozzle “F” with that contained in the conversion kit, placing it inside the gasket “G”.
  • Página 252 FORCE W • For Models W 99, W 120 and W 150 Remove the gas valve control unit (fig. 68). Undo the screws “C” (fig. 69) securing the fan and remove the unit (fig. 70). fig. 68 fig. 69 Undo the screws “E” and then replace the gas nozzle “F” with that contained in the conversion kit, placing it inside the gasket “G”.
  • Página 253 FORCE W • For all models Modify the parameter for the type of gas as described below. Reach the screen shown in fig. 72, navigating in the menu and following the path "USER MENU Maintenance Test Mode Gas Type Selection”. Press contextual buttons 1 and 2 to select the type of gas. Confirm with the OK button.
  • Página 254 FORCE W fig. 73- Maximum adjustment, models W 60 and W 80 fig. 74- Minimum adjustment, models W 60 and W 80 fig. 75- Maximum and minimum adjustment, models W 99, W 120 and W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 255 FORCE W TEST mode activation Reach the screen shown in fig. 76, navigating the following menu path: "USER MENU Maintenance Test Mode Test mode”. The boiler will light, gradually reaching the maximum heating power (Range Rated) set as described in the next section. The display will show the actual heating power and that set.
  • Página 256: Technical Menu

    FORCE W TECHNICAL MENU ONLY QUALIFIED PERSONNEL CAN ACCESS THE SERVICE MENU AND MODIFY PARAMETERS. The Technical Menu can only be accessed after entering the code 4 1 8. It is valid for 15 minutes. Configuration - Parameters Menu 16 parameters are available, indicated by the letter “b”, which are not modifiable from Remote Timer Control. Table 6- Parameters - Configuration Parameter Description Range...
  • Página 257 FORCE W Parameter Description Range W 60 W 80 W 99 W 120 W 150 Heating Post-Circulation 0-255 minutes Pump operation 0-3 Operation strategy Modulating pump min. speed 0-100% Modulating pump start speed 0-100% Modulating pump max. speed 30-100% Pump deactivation temperature during Post-Circulation 0-100°C Pump activation hysteresis temperature during Post-Circulation 0-20°C...
  • Página 258 FORCE W System Type - Parameters Menu 23 parameters are available, indicated by the letter “P.” which are not modifiable from Remote Timer Control. Parameter Description Range W 60 W 80 W 99 W 120 W 150 0 = Normal heating request 1 = Request from remote control with external on-off enabling 2 = 0-10V signal request with temperature control with exter- nal on-off enabling...
  • Página 259: Commissioning

    FORCE W 3.2 Commissioning Checks to be done at first lighting, and after all maintenance operations that in- volved disconnection from the systems or work on safety devices or parts of the boiler: Before lighting the boiler • Open any on-off valves between the boiler and the systems. •...
  • Página 260 FORCE W • Check and cleaning of electrodes, which must be free of deposits and properly positioned. • Check of gaskets and seals (burner, sealed chamber, etc.). • Check and cleaning of sludge remover filters and system filters. • Check, cleaning and filling of condensate drain traps. •...
  • Página 261 FORCE W Extraordinary maintenance and replacement of components Electrode replacement Exchanger cleaning cod. 3541V232 - Rev 00 - 08/2021...
  • Página 262: Troubleshooting

    FORCE W 3.4 Troubleshooting Diagnostics The boiler is equipped with an advanced self-diagnosis system. In case of a boiler fault, the display lights up indicating the fault code and, in case of cascade connection, the module number. • There are faults that cause permanent shutdowns which can be reset by pressing the OK button for one second or with the RESET button on the remote timer control (optional) if installed.
  • Página 263 FORCE W Fault Fault Possible cause Cure code Sensor damaged Return sensor fault Wiring shorted Check the wiring or replace the sensor Wiring disconnected Sensor damaged DHW sensor fault Wiring shorted Check the wiring or replace the sensor Wiring disconnected Sensor damaged Fume sensor fault Wiring shorted...
  • Página 264: Technical Data And Characteristics

    FORCE W 4. Technical data and characteristics Legend of figures cap. 4 "Technical data and characteristics" Gas inlet - Ø 3/4” System flow - Ø 1” 1/2 System return - Ø 1” 1/2 Safety valve Heating circulating pump (not supplied) Heating temperature sensor Automatic air vent Gas valve...
  • Página 265: Dimensions And Connections

    FORCE W 4.1 Dimensions and connections fig. 79- Front view fig. 80- Side view fig. 81- Top view fig. 82- Top view cod. 3541V232 - Rev 00 - 08/2021...
  • Página 266: General View

    4.2 General view fig. 84- General view - model FORCE W 99 and FORCE W 120 fig. 83- General view - model FORCE W 60 and FORCE W 80 fig. 85- General view - model FORCE W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 267: Hydraulic Circuit

    FORCE W 4.3 Hydraulic circuit fig. 86- Hydraulic circuit cod. 3541V232 - Rev 00 - 08/2021...
  • Página 268: Technical Data Table

    FORCE W 4.4 Technical data table The column on the right gives the abbreviation used on the data plate. cod. 3541V232 - Rev 00 - 08/2021...
  • Página 269 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 270: Erp Tables

    FORCE W 4.5 ErP tables cod. 3541V232 - Rev 00 - 08/2021...
  • Página 271 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 272 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 273 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 274 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 275: Diagrams

    FORCE W 4.6 Diagrams Pressure loss fig. 87- Pressure loss diagram - models FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 fig. 88- Pressure loss diagram - models FORCE W 150 Delivery - m...
  • Página 276: Wiring Diagrams

    FORCE W 4.7 Wiring diagrams The legend of the figures is on page 264. ATTENTION: Remove the jumper on the terminal block before connecting the room thermostat or the remote timer control. ATTENTION: To connect the 3-way valve (terminals 13 - 14 - 15), refer to the diagrams of fig. 89 and fig. 90. fig.
  • Página 277 FORCE W fig. 92- Wiring diagram - models FORCE W 60 and FORCE W 80 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 278 FORCE W fig. 93- Wiring diagram - models FORCE W 99, FORCE W 120 and FORCE W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 279: Pays De Destination: It Es Ro Ru Pl

    FORCE W • Lire attentivement les avertissements repris dans le • Pour garantir le bon fonctionnement de l'appareil, il présent manuel d'instructions fournissant des indi- est indispensable de faire effectuer un entretien cations importantes pour la sécurité de l'installation, périodique par un professionnel qualifié. son utilisation et son entretien.
  • Página 280 FORCE W 1 Instructions d’utilisation ..................... 281 1.1 Introduction............................281 1.2 Tableau des commandes ........................281 1.3 Allumage et extinction ........................285 1.4 Réglages ............................286 2 Installation ..........................294 2.1 Dispositions générales ........................294 2.2 Emplacement ............................. 294 2.3 Raccordements hydrauliques ......................294 2.4 Raccordement gaz ..........................
  • Página 281: Instructions D'utilisation

    1.1 Introduction Cher Client, Nous vous remercions d'avoir choisi FORCE W, une chaudière murale à chambre étanche FERROLI de conception avancée, technologie de pointe, haute fiabilité et qualité de construction. Lire attentivement les instructions contenues dans la présente notice, car elles fournissent des indications importantes concernant la sécurité d'installation, l'utilisa- tion et l'entretien de l'appareil.
  • Página 282 FORCE W Touches directes Les touches directes (rep. 8, 9, 10 - fig. 1) ont toujours la même fonction. Touches de navigation/menu Les touches navigation/menu (rep. 5, 6, 7, 11, 12, 13 - fig. 1) servent à naviguer parmi les différents menus disponibles sur le panneau de contrôle.
  • Página 283 FORCE W ENTRETIEN Voir fig. 76 Mode TEST Voir fig. 72 Mode TEST Sélection type de gaz Mode test cascade Voir “Information de Service” on page 291 Information de Service Voir “Date Intervention Service” on page 291 Date Intervention Service CONFIGURATIONS Voir fig.
  • Página 284 FORCE W Exclusion du ballon (ECO) L'utilisateur peut exclure le chauffage/maintien de la température dans le ballon En cas d'exclusion, l'eau chaude sanitaire ne sera pas disponible. Le ballon peut être désactivé par l'utilisateur (mode ECO) en ap- puyant sur le bouton eco/confort (part. 10 - fig. 1). En 23°C 32°C mode ECO l’écran affiche le pictogramme...
  • Página 285: Allumage Et Extinction

    FORCE W 1.3 Allumage et extinction Allumage de la chaudière Appuyer sur le bouton marche/arrêt (par 14 - fig. 1). que le thermostat d'ambiance relève un besoin thermique (demande) En appuyant sur la touche contextuelle 1 il est possi- ble de choisir la langue souhaitée et de la valider avec la touche «...
  • Página 286: Réglages

    FORCE W Extinction de la chaudière À partir de la page principale/Accueil, appuyer sur la Pour débrancher complètement l'appareil de l'alimen- touche contextuelle et confirmer avec la touche tation électrique, appuyez sur la touche part. 14 fig. 1. Au moment où l'on éteint la chaudière, la carte électro- nique reste encore sous tension.
  • Página 287 FORCE W Réduction de la température de chauffage Accéder au menu « Temp réglage réduction » pour Température de consigne réduit faire varier la température d'un minimum de 0°C à un maximum de 50°. Confirmer en appuyant sur OK. Ce paramètre n'est utilisé que si la program- mation horaire est activée.
  • Página 288 FORCE W Sélectionner le jour (fig. 17) ou l'intervalle de jours à programmer (fig. 18) et valider avec la touche OK. Programmation horaires Programmation horaires Lundi Mercredi Jeudi Mardi Vendredi Mercredi Samedi Jeudi Dimanche Vendredi Lundi-Dimanche Samedi Lundi-Vendredi Dimanche Samedi-Dimanche Lundi-Dimanche pour confirmer pour confirmer...
  • Página 289 FORCE W Appuyer sur la touche de navigation 7 et utiliser les Programmation horaires touches contextuelles 1 et 2 pour régler le mode de fonctionnement pendant la première tranche horaire 06:00 - 16:00 (fig. 21) --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:--...
  • Página 290: En Mode Vacances

    FORCE W Pour restaurer le programme horaire aux va- Programmation horaires leurs d'usine, appuyer sur la touche contex- tuelle 3 dans le menu Programme horaire Lundi (fig. 26) et valider par OK. Mardi Mercredi Jeudi Vendredi Samedi Dimanche Lundi-Dimanche pour confirmer fig.
  • Página 291 FORCE W Fonction vacances Accéder au menu « FONCTION VACANCES » à travers le parcours « MENU UTILISATEUR « FONCTION VA- CANCES » pour pouvoir définir : • Date début Vacances. • Date fin Vacances. L'afficheur peut activer deux types d'icônes : •...
  • Página 292 FORCE W Régler le déplacement parallèle des courbes de 20 à Décalage paral. de pente 1 60°C (fig. 31), à l'aide du paramètre « Offset1 » et va- lider avec la touche OK. pour confirmer fig. 29- Déplacement parallèle des courbes Si la température ambiante est inférieure à...
  • Página 293: Réglages À Partir De La Chronocommande À Distance

    FORCE W Réglages à partir de la chronocommande à distance Si la chaudière est reliée à la chronocommande à distance (option), les réglages ci-dessus seront gérés com- me indiqué dans le tableau tableau 1. Tableau 1 Réglage de la température de chauf- Le réglage peut être effectué...
  • Página 294: Installation

    FORCE W 2. Installation 2.1 Dispositions générales L'INSTALLATION DE LA CHAUDIÈRE DOIT ÊTRE EFFECTUÉE CONFORMÉMENT AUX TEXTES RÉGLEMENTAI- RES ET RÈGLES DE L'ART EN VIGUEUR, SUIVANT LES INSTRUCTIONS DU CONSTRUCTEUR ET PAR UN PRO- FESSIONNEL QUALIFIÉ. 2.2 Emplacement Le générateur doit être installé dans un local approprié, muni d'ouvertures d'aération vers l'extérieur, conformément aux normes en vigueur.
  • Página 295 FORCE W Circulateur haute efficacité (en option) La configuration standard s'adapte à tous les types d'installation ; il est toutefois possible de définir un mode de fonc- tionnement différent en fonction des caractéristiques de l'installation à travers le sélecteur de vitesse (voir fig. 33) . 1 2 3 fig.
  • Página 296: Installation Existante

    FORCE W Caractéristiques de l'eau de l'installation Avant de procéder à l'installation du générateur FORCE W, l'installation, nouvelle ou existante, doit être correctement nettoyée afin d'éliminer les résidus d'installation, les solvants, les boues et les contaminants en général pouvant em- pêcher l'efficacité...
  • Página 297: Maintenance Chambre De Combustion

    FORCE W Vérifiez toujours la concentration du produit après chaque introduction et de ma- nière cyclique, au moins une fois par an, à l’aide d’un personnel technique qualifié tel que celui de notre réseau d'assistance technique agréé. Tableau 2- Les agents de conditionnement chimiques déclarés appropriés et disponibles auprès de notre réseau de centres d'assistance technique agréés Description Produits alternatifs type Sentinel...
  • Página 298 FORCE W composants et/ou matériaux de la chaudière et de l'installation. Il est interdit d'utiliser des liquides antigel, des additifs et des inhibiteurs non spécifiquement prévus pour l'utilisation dans des circuits thermiques et compatibles avec les ma- tériaux composant la chaudière et le circuit. Kit options Sur demande, les kits suivants sont disponibles : réf.
  • Página 299 FORCE W Exemples de circuits hydrauliques Dans les exemples décrits ci-après, il pourrait être né- MENU cessaire de vérifier/modifier certains paramètres. UTILISATEUR Pour cela, accéder d'abord au menu Technicien. À partir de la page principale (Accueil), appuyer sur la touche Menu principal (rep. 12 - fig. 1). TECHNIQUE Accéder au menu «...
  • Página 300: Branchements Électriques

    FORCE W Deux circuits chauffage directs - Schéma de principe fig. 42 - Branchements électriques Après l’installation, effectuer les branchements électriques nécessaires comme le montre le schéma électrique. Après quoi, configurer l'unité comme indiqué dans le paragraphe correspondant. Légende (fig. 42 et fig. 43) 9 10 11 12 13 14 15 16 17 18 Thermostat d'ambiance 1ère zone (directe) 72b Thermostat d'ambiance 2e zone (directe)
  • Página 301: Paramètres

    FORCE W - Paramètres Chaque circuit doit être configuré individuellement. Suivre la procédure d'accès indiquée ci-après. « Menu Type Installation » Modifier le paramètre P.01 du « Menu Type Installation » sur 4. - Fonctions optionnelles En plus des connexions électriques de la figure précédente (nécessaires pour cette configuration système), il existe des options qui ne nécessitent aucun réglage.
  • Página 302 FORCE W Un circuit chauffage direct et un circuit eau chaude sanitaire avec circulateur - Schéma de principe fig. 45 - Branchements électriques Après l’installation, effectuer les branchements électriques nécessaires comme le montre le schéma électrique. Après quoi, configurer l'unité comme indiqué dans le paragraphe correspondant. Légende (fig.
  • Página 303 FORCE W - Paramètres Chaque circuit doit être configuré individuellement. Suivre la procédure d'accès indiquée ci-après. « Menu Paramètres - Configuration » Vérifier/Modifier paramètre b02 du « Menu Paramètres Transparents » sur 8. Vérifier/Modifier paramètre b08 du « Menu Paramètres Transparents » sur 1. Vérifier/Modifier paramètre b04, b05 et b06 du «...
  • Página 304 FORCE W Un circuit chauffage direct et un circuit eau chaude sanitaire avec by-pass (3 fils) - Schéma de principe Utiliser des by-pass à 3 fils : - PHASE D’OUVERTURE 230 V - PHASE DE FERMETURE 230 V - NEUTRE avec temps de commutation (de fermé...
  • Página 305 FORCE W Légende (fig. 48 et fig. 49) Circulateur circuit chauffage Circuit ballon Thermostat d'ambiance 1ère zone (directe) Départ 138 Sonde extérieure Retour 155 Capteur ballon K1 - K2bobine 230 Vca , < 2,2 VA 348 Vanne 3 voies (trois fils) contact 230 Vca , >...
  • Página 306 FORCE W Deux circuits chauffage mélangés, un circuit chauffage direct et un circuit eau chaude sanitaire avec circulateur - Schéma de principe La carte contrôle zones FZ4B peut commander plusieurs types d'installation. Type d'installation cité comme exemple. Utiliser des by-pass à 3 fils : - PHASE D’OUVERTURE 230 V - PHASE DE FERMETURE 230 V - NEUTRE...
  • Página 307 FORCE W - Branchements électriques Après l’installation, effectuer les branchements électriques nécessaires comme le montre le schéma électrique. Après quoi, configurer l'unité comme indiqué dans le paragraphe correspondant. cod. 3541V232 - Rev 00 - 08/2021...
  • Página 308 FORCE W 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 L _ N L _ N L _ N L _ N BUS RT1 RT2 RT3...
  • Página 309 FORCE W Légende (fig. 51 et fig. 52) 72a Thermostat d'ambiance 1ère zone (mélangée) B = NEUTRE 72b Thermostat d'ambiance 2e zone (mélangée) C = PHASE DE FERMETURE 72c Thermostat d'ambiance 3e zone (directe) 317a Thermostat de sécurité 1ère zone (mélangée) 130 Circulateur ballon 317b Thermostat de sécurité...
  • Página 310: Raccordement Gaz

    FORCE W 2.4 Raccordement gaz Avant d'effectuer le raccordement, veiller à ce que l'appareil soit préparé pour fon- ctionner avec le type de combustible disponible et prendre soin de bien nettoyer les conduites du circuit afin d'en retirer tout résidu pouvant compromettre le bon fonctionnement de la chaudière.
  • Página 311 FORCE W alimentation doit se faire par raccordement direct au secteur ou par piles selon le type de dispositif. Sonde extérieure (option) Relier la sonde aux bornes La longueur maximale admissible du câble électrique de raccordement chaudière - sonde extérieure est de 50 m. Un câble à 2 conducteurs commun peut être utilisé. La sonde extérieure doit être installée de préférence sur le mur orienté...
  • Página 312: Configuration

    FORCE W Pour le montage en cascade REMARQUE : l'électronique de la chaudière est en mesure de gérer jusqu'à 6 modules maximum. 1. Relier les modules comme le montre la fig. 56 (exemple avec 3 modules) fig. 56 - Montage en cascade A 1er Module C 3e Module B 2e Module...
  • Página 313 FORCE W Générateurs en cascade : un circuit de chauffage direct et un circuit sanitaire avec circulateur Schéma de principe L'électronique de la chaudière est capable de gérer jusqu'à 6 modules maximum. L’exemple en montre 3. fig. 57 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 314 FORCE W Branchements électriques Après l’installation, effectuer les branchements électriques nécessaires comme le montre le schéma électrique. Après quoi, configurer l'unité comme indiqué dans le paragraphe correspondant. 300M 300S 9 10 11 12 13 14 15 16 17 18 9 10 11 12 13 14 15 16 17 18 SLAVE 1 MASTER 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36...
  • Página 315 230 Vca « Pour plus de schémas de raccordement en cascade, hydraulique et électrique, consulter le site www.ferroli.com dans la rubrique dédiée aux produits RESIDENTIEL, Chaudières, FORCE W et à télécharger les documents techniques qui contiennent toutes les spécifications et configuration d'installation à...
  • Página 316: Conduits De Fumée

    FORCE W 2.6 Conduits de fumée LES CHAUDIÈRES DOIVENT ÊTRE INSTALLÉES DANS DES PIÈCES RÉPONDANT AUX EXIGENCES D'AÉRATION DE BASE. À DÉFAUT, IL Y A UN DANGER D'ASPHYXIE OU D'EMPOISONNEMENT. LIRE LES CONSIGNES D'INSTALLATION ET D'ENTRETIEN AVANT D'IN- STALLER L'APPAREIL. RESPECTER ÉGALEMENT LES INSTRUCTIONS DE CONCEPTION.
  • Página 317 TERMINAL Exemples de calcul FORCE W 60: hauteur d’élévation disponible 77 Pa 5 mètres TUYAU Ø80 + 3 COUDES Ø80 = (5 x 4,8) + (3 x 10)= 55<77 = OK 8 mètres TUYAU Ø80 + 6 COUDES Ø80 = (8 x 4,8) + (6 x 10)= 100>77 = NO Conduits de fumée...
  • Página 318: Raccordement De L'évacuation Des Condensats

    FORCE W Les éventuelles parties horizontales de l'évacuation des fumées doivent avoir une légère pente vers la chaudière pour éviter que l'éventuelle eau de condensation ne coule et ne goutte vers l'extérieur. Avant de procéder à l'installation, consulter le tableau tableau 5 que la longueur maximale admissible ne soit dépassée, compte tenu que la mise en place d'un coude coaxial supplémentaire entraîne la réduction de la longueur indiquée dans le tableau.
  • Página 319: Utilisation Et Entretien

    SAV. FERROLI Toute responsabilité du constructeur est exclue pour les dommages aux biens et/ou personnes causés par des modification de l’appareil par des personnes non qualifiées et non autorisées.
  • Página 320 FORCE W • Pour modèles W 60 et W 80 Dévisser les vis « B » et retirer le groupe « Venturi/vanne à gaz » (fig. 66). Dévisser les vis « E » puis remplacer le gicleur-buse à gaz « F » par celle contenue dans le kit de transformation en la plaçant à...
  • Página 321 FORCE W • Pour les modèles W 99, W 120 et W 150 Extraire le boîtier de commande de la vanne à gaz (fig. 68). Dévisser les vis « C » (fig. 69) qui fixent le ventilateur et extraire le groupe (fig. 70). fig.
  • Página 322: Gaz Naturel

    FORCE W • Pour tous les modèles Modifier le paramètre concernant le type de gaz en procédant comme décrit ci-après. Accéder à la page qui s'affiche sur fig. 72 en naviguant à travers le menu à travers le parcours « MENU UTILISA- TEUR »...
  • Página 323 FORCE W fig. 73- Réglage maximum modèles W 60 et W 80 fig. 74- Réglage minimum modèles W 60 et W 80 fig. 75- Réglage maxi et mini modèles W 99, W 120 et W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 324: Réglage De La Puissance Thermique (Range Rated)

    FORCE W Activation du mode TEST Accéder à la page qui s'affiche sur fig. 76 en naviguant dans le menu en suivant le chemin « MENU UTILISATEUR Entretien Mode Test Mode test ». La chaudière s'allume à la puissance maximale de chauffage (Range Rated) fixée, comme l'indique le paragraphe sui- vant, de façon progressive.
  • Página 325: Menu Technicien

    FORCE W MENU TECHNICIEN L’ACCÈS AU MENU SERVICE ET LA MODIFICATION DES PARAMÈTRES NE PEUVENT ÊTRE EFFECTUÉS QUE PAR UN PERSONNEL QUALIFIÉ. L'accès au Menu Technicien n'est possible qu'après avoir saisi le code 4 1 8. La durée de validité de celui-ci est de 15 minutes.
  • Página 326 FORCE W Menu Paramètres - Transparents 31 paramètres indiqués par la lettre « P » sont disponibles : ils sont modifiables à partir de la chronocommande à di- stance. Tableau 7- Paramètres - Transparents Paramètre Description Plage W 60 W 80 W 99 W 120 W 150 Puissance d'allumage 0-100 % Rampe chauffage...
  • Página 327 FORCE W Paramètre Description Plage W 60 W 80 W 99 W 120 W 150 Valeur nominale pression installation 0 = Non F43, Déclenchement de la protection échangeur 1-15 = 1-15 °C/seconde Hystérésis chauffage après allumage 6-30°C Minuterie hystérésis chauffage après allumage 0-180 secondes Remarques 1.
  • Página 328: Mise En Service

    FORCE W Paramètre Description Plage W 60 W 80 W 99 W 120 W 150 P.22 Activation sanitaire chaudière esclave (autocascade) OFF = Désactivé, ON = Activé OFF OFF OFF OFF P.23 Confort continu chaudière esclave (Ax5200SQ) OFF = Désactivé, ON = Activé OFF OFF OFF OFF Remarques 1.
  • Página 329: Entretien

    FORCE W 3.3 Entretien AVERTISSEMENTS TOUTES LES OPÉRATIONS D'ENTRETIEN ET DE REMPLACEMENT DOI- VENT ÊTRE CONFIÉES À DES TECHNICIENS SPÉCIALISÉS ET QUALIFIÉS. Avant d'effectuer une quelconque opération à l'intérieur de la chaudière, la mettre hors tension et fermer le robinet du gaz en amont Le non-respect de cette consigne entraîne le risque d'explosion, d'électrocution, d'asphyxie ou d'empoisonnement.
  • Página 330 FORCE W Ouverture du panneau avant Certains composants logés à l’intérieur de l’unité peuvent atteindre des tem- pératures élevées pouvant provoquer des brûlures graves.Avant d’effectuer une opération quelconque, attendre le refroidissement desdits composants ou bien porter des gants de protection appropriés. Pour retirer le capot avant de la chaudière : 1.
  • Página 331 FORCE W Entretien extraordinaire et remplacement des composants Remplacement de l’électrode Nettoyage de l’échangeur cod. 3541V232 - Rev 00 - 08/2021...
  • Página 332: Dépannage

    FORCE W 3.4 Dépannage Diagnostic La chaudière est équipée d'un dispositif d'autodiagnostic avancé. Dans le cas d’anomalie ou de dysfonctionnement de la chaudière, l’afficheur s’illumine indiquant le code d'erreur et, dans le cas de raccordement en cascade, le numéro du module.
  • Página 333 FORCE W Code Anomalie Causes probables Solution anomalie Capteur endommagé Anomalie capteur Câblage en court-circuit Contrôler le câblage ou remplacer le capteur chauffage 1 (départ) Câblage interrompu Capteur endommagé Anomalie capteur de Câblage en court-circuit Contrôler le câblage ou remplacer le capteur retour Câblage interrompu Capteur endommagé...
  • Página 334: Caractéristiques Et Données Techniques

    FORCE W 4. Caractéristiques et données techniques Légende des figures cap. 4 "Caractéristiques et données techniques" Arrivée gaz - Ø 3/4” Départ installation - Ø 1” 1/2 Retour installation - Ø 1” 1/2 Soupape de sécurité Ventilateur Circulateur circuit chauffage (non fourni) Capteur de température chauffage Purgeur d’air automatique Vanne à...
  • Página 335: Dimensions Et Raccords

    FORCE W 4.1 Dimensions et raccords fig. 79- Vue de face fig. 80- Vue latérale fig. 81- Vue de dessus fig. 82- Vue de dessus cod. 3541V232 - Rev 00 - 08/2021...
  • Página 336: Vue Générale

    4.2 Vue générale fig. 84- Vue générale mod. FORCE W 99 et FORCE W 120 fig. 83- Vue générale mod. FORCE W 60 et FORCE W 80 fig. 85- Vue générale mod. FORCE W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 337: Circuit Hydraulique

    FORCE W 4.3 - Circuit hydraulique fig. 86- Circuit hydraulique cod. 3541V232 - Rev 00 - 08/2021...
  • Página 338: Tableau Des Caractéristiques Techniques

    FORCE W 4.4 Tableau des caractéristiques techniques La colonne de droite indique l'abréviation utilisée sur la plaquette des caractéristiques techniques. cod. 3541V232 - Rev 00 - 08/2021...
  • Página 339 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 340 FORCE W 4.5 Tableaux ErP cod. 3541V232 - Rev 00 - 08/2021...
  • Página 341 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 342 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 343 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 344 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 345: Diagrammes

    4.6 Diagrammes Perte de charge fig. 87- Diagramme perte de charge modèles FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 fig. 88- Diagramme perte de charge modèles FORCE W 150 Débit - m...
  • Página 346: Schémas Électriques

    FORCE W 4.7 Schémas électriques La légende des figures se trouve à page 334. ATTENTION : Avant de brancher le thermostat d'ambiance ou la chronocommande à distance, retirer le cavalier du bornier. ATTENTION : pour raccorder la vanne 3 voies (bornes 13 - 14 - 15), se référer aux schémas de fig. 89 et fig. 90. fig.
  • Página 347 FORCE W fig. 92- Schéma électrique modèles FORCE W 60 et FORCE W 80 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 348 FORCE W fig. 93- Schéma électrique modèles FORCE W 99, FORCE W 120 et FORCE W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 349 FORCE W • Данный символ означает "Осторожно" и сопровождает все указания, касающиеся безопасности. Строго придерживайтесь таких указаний во избежание опасности вреда для здоровья людей и животных и материального ущерба. Макс. теплопроизводительность системы ГВС (Hi) Qnw (Hi) Manufacturer / Производитель: Manufacturer address: Данный...
  • Página 350 FORCE W 1 Инструкции по эксплуатации................... 351 1.1 Предисловие ............................. 351 1.2 Панель управления .......................... 351 1.3 Включение и выключение ........................ 355 1.4 Регулировки ............................356 2 Установка..........................364 2.1 Указания общего характера......................364 2.2 Место установки ..........................364 2.3 Гидравлические подключения ......................364 2.4 Газовые...
  • Página 351: Инструкции По Эксплуатации

    1.1 Предисловие Уважаемый покупатель! Благодарим вас за выбор FORCE W, настенного котла с закрытой камерой сгорания FERROLI прогрессивного дизайна, выполненного по передовым технологиям и отличающегося высокой надежностью и качеством конструкции. Просим Вас внимательно прочитать настоящее руководство, поскольку в нем содержатся важные указания по безопасности установки, эксплуатации...
  • Página 352 FORCE W Однозначные клавиши Однозначные клавиши (поз. 8, 9, 10 - рис. 1) всегда выполняют одну и ту же функцию. Клавиши навигации/меню Клавиши навигации/меню (поз. 5, 6, 7, 11, 12, 13 - рис. 1) служат для навигации между разными меню на панели управления. Структура...
  • Página 353 FORCE W ТЕХНИЧЕСКОЕ ОБСЛУЖИВАНИЕ См. рис. 76 Тестовый режим См. рис. 72 Выбор типа газа Тестовый режим Тестовый режим каскад Информация о Сервисной См. “Информация о Сервисной службе” on page 361 службе Дата проведения сервисных См. “Дата проведения сервисных операций” on page 361 операций...
  • Página 354 FORCE W Исключение бойлера (режим Еconomy) Пользователь имеет возможность исключать систему нагрева/поддержания температуры воды в бойлере. В этом случае котлом не вырабатывается вода для ГВС. Котел может быть отключен пользователем (режим ECO) нажатием кнопки Eco/Comfort (поз. 10 - рис. 1). В режиме...
  • Página 355: Включение И Выключение

    FORCE W 1.3 Включение и выключение Включение котла Нажмите на кнопку включения/выключения (поз. 14 - рис. 1). Нажав контекстную кнопку 1, можно выбрать желаемый язык и подтвердить его клавишей «ОК». Нажав контекстную кнопку 3, можно прервать режим FH. Если не выбран ни один из двух вышеописанных вариантов, действуйте...
  • Página 356: Выключение Котла

    FORCE W Выключение котла В главном экранном окне (Home) нажмите на контекстную клавишу и подтвердите с помощью кнопки Когда котел выключен, на электронную плату продолжает подаваться электрическое питание. В этом случае не происходит нагрев воды для ГВС (при наличии внешнего бойлера) и отопления Остается активной...
  • Página 357 FORCE W Снижение температуры отопления Войдите в меню “Понижение температуры CH setpoint reduction регулировки” для изменения температуры от минимум 0°C до максимум 50°С. Подтвердите с помощью кнопки Этот параметр используется, только если включено программирование графика работы по часам. См. ”Программирование графика работы...
  • Página 358 FORCE W Выберите день (рис. 17) или интервал из нескольких дней для программирования (рис. 18) и подтвердите кнопкой OK. Scheduler Set Scheduler Set Wednesday Monday Tuesday Thursday Friday Wednesday Saturday Thursday Sunday Friday Monday-Sunday Saturday Monday-Friday Sunday Saturday-Sunday Monday-Sunday to confirm to confirm рис.
  • Página 359 FORCE W Нажмите кнопку навигации 7 и используйте контекстные Scheduler Set кнопки 1 и 2, чтобы задать режим работы в течение первого временного интервала (рис. 21). 06:00 - 16:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- Copy to the Next Day Save &...
  • Página 360 FORCE W Чтобы восстановить заводские значения Scheduler Set графика работы, нажмите контекстную кнопку 3 в меню График работы (рис. 26) и Monday подтвердите с помощью OK. Tuesday Wednesdey Thursday Friday Saturday Sunday Monday-Sunday to confirm рис. 26 Две часовые программы отопления и ГВС независимы даже в случае возврата к заводским значениям. Программирование...
  • Página 361 FORCE W Функция отпуска Войдите в меню “ФУНКЦИЯ ОТПУСКА” по маршруту “МЕНЮ ПОЛЬЗОВАТЕЛЯ “ФУНКЦИЯ ОТПУСКА”, чтобы задать: • Дату начала отпуска. • Дату окончания отпуска. На дисплее могут появится два типа иконок: • - Функция Отпуска запрограммирована, но не активирована. •...
  • Página 362 FORCE W Отрегулируйте параллельное смещение кривых от 20 до OTC Offset 1 60°C (рис. 31), используя параметр “Offset1”, и подтвердите клавишей OK. to confirm рис. 29- Параллельное смещение кривых Если температура в помещении оказывается ниже желаемой, рекомендуется выбрать характеристику более высокого порядка...
  • Página 363 FORCE W Регулирование с дистационного пульта управления с таймером Если к котлу подключено устройство дистанционного управления с таймером (опция), вышеописанные регулировки производятся в соответствии с указаниями, приведенными в таблица 1. Таблица 1 Регулировка температуры воды в Регулировку можно произвести как из меню пульта ДУ с таймером, так и с панели системе...
  • Página 364: Установка

    FORCE W 2. Установка 2.1 Указания общего характера УСТАНОВКА И НАСТРОЙКА ГОРЕЛКИ ДОЛЖНА ОСУЩЕСТВЛЯТЬСЯ ТОЛЬКО СПЕЦИАЛИЗИРОВАННЫМ ПЕРСОНАЛОМ, ИМЕЮЩИМ ПРОВЕРЕННУЮ КВАЛИФИКАЦИЮ, ПРИ СОБЛЮДЕНИИ ПРИВЕДЕННЫХ В НАСТОЯЩЕМ ТЕХНИЧЕСКОМ РУКОВОДСТВЕ УКАЗАНИЙ, ПРЕДПИСАНИЙ ДЕЙСТВУЮЩЕГО ЗАКОНОДАТЕЛЬСТВА, ПОЛОЖЕНИЙ МЕСТНЫХ НОРМ И ПРАВИЛ, И В СООТВЕТСТВИИ С ПРИНЯТЫМИ ТЕХНИЧЕСКИМИ ТРЕБОВАНИЯМИ. 2.2 Место...
  • Página 365 FORCE W Высокопроизводительный циркуляционный насос (опция) Заводская настройка подходит для всех установок; тем не менее, с помощью регулятора скорости (см. рис. 33), можно задавать иную стратегию работы в зависимости от характеристик системы. 1 2 3 рис. 33 Настройка Dp-v Настройка Dp-c Настройка...
  • Página 366 FORCE W Характеристики воды в системе Перед установкой генератора FORCE W система, будь она новой или уже эксплуатируемой, должна быть должным образом очищена, чтобы удалить загрязнения, оставшиеся после монтажа, растворители, шлам и загрязняющие вещества в целом, поскольку они могут нарушить эффективность защитных кондиционирующих присадок. Используйте нейтральные неагрессивные...
  • Página 367 FORCE W Таблица 2- Рекомендуемые химические кондиционирующие присадки, доступные в нашей авторизованной сервисной сети Альтернативные средства типа Описание Sentinel LIFE PLUS/B - MOLY - MOLY K Антикоррозийное средство на основе молибдена X100 LIFE DUE Шумоподавление/профилактическая защита от накипи X200 BIO KILL Биоцидное...
  • Página 368 FORCE W Дополнительные комплекты оснащения По заказу поставляются следующие комплекты: арт. 042070X0 - КОМПЛЕКТ ВЫСОКОПРОИЗВОДИТЕЛЬНОГО ЦИРКУЛЯЦИОННОГО НАСОСА - 7 м (A - рис. 37) арт. 042071X0 - КОМПЛЕКТ ВЫСОКОПРОИЗВОДИТЕЛЬНОГО ЦИРКУЛЯЦИОННОГО НАСОСА - 10 м (A - рис. 37) арт. 042072X0 - ГИДРАВЛИЧЕСКИЙ КОМПЛЕКТ В...
  • Página 369 FORCE W Примеры гидравлических контуров В нижеприведенных примерах может потребоваться MENU проверить/изменить некоторые параметры. Для этого необходимо войти в меню «Техника». USER В главном экранном окне (Home) нажмите на клавишу «Главного меню» (поз. 12 - рис. 1). Войдите в меню “Техника" путем нажатия на контекстную TECHNICIAN клавишу...
  • Página 370: Электрические Соединения

    FORCE W Два прямых контура отопления - Принципиальная схема рис. 42 - Электрические соединения После монтажа будет необходимо выполнить необходимые электрические подключения, как показано на электрической схеме. Вслед за этим выполните конфигурацию блока управления согласно указаниям соответствующего параграфа. Спецификация (рис. 42 и рис. 43) 9 10 11 12 13 14 15 16 17 18 Комнатный...
  • Página 371: Дополнительные Функции

    FORCE W - Параметры Каждая система нуждается в различной настройке параметров. Необходимо следовать приведенной далее процедуре. Меню «Тип системы» Измените параметр P.01 в меню "Тип системы” на 4. - Дополнительные функции В дополнение к электрическим соединениям на предыдущем рисунке (необходимым для данной конфигурации системы) есть опции, которые...
  • Página 372: Принципиальная Схема

    FORCE W Прямой отопительный контур и контур ГВС с циркуляционным насосом. - Принципиальная схема рис. 45 - Электрические соединения После монтажа будет необходимо выполнить необходимые электрические подключения, как показано на электрической схеме. Вслед за этим выполните конфигурацию блока управления согласно указаниям соответствующего параграфа. Спецификация...
  • Página 373 FORCE W - Параметры Каждая система нуждается в различной настройке параметров. Необходимо следовать приведенной далее процедуре. Меню "Параметры - Конфигурация" Проверьте/измените параметр b02 в меню "Прозрачных параметров" на 8. Проверьте/измените параметр b08 в меню "Прозрачных параметров" на 1. Проверьте/измените параметры b04, b05 и b06 меню "Прозрачных параметров" в соответствии со значениями, приведенными...
  • Página 374 FORCE W Прямой отопительный контур и контур ГВС с распределительным клапаном (3-проводной) - Принципиальная схема Используйте 3-проводные отводящие клапаны: - ФАЗА РАЗМЫКАНИЯ 230 В - ФАЗА ЗАМЫКАНИЯ 230 В - НЕЙТРАЛЬ со временем переключения (от полностью замкнутого до полностью разомкнутого) не более 90 секунд. рис.
  • Página 375 FORCE W Спецификация (рис. 48 и рис. 49) Циркуляционный насос системы отопления Контур бойлера Комнатный термостат 1-й зоны (прямого контура) Нагнетательный контур Датчик наружной температуры Возвратный контур Датчик бойлера K1 - K2катушка 230 В перем. тока, < 2,2 ВА 3-ходовой клапан (трехпроводной) контакт...
  • Página 376 FORCE W Два отопительных контура со смесительным клапаном, прямой отопительный контур и контур ГВС с циркуляционным насосом - Принципиальная схема Плата контроля зон FZ4B может управлять отопительными системами различных типов. На рисунке приводится пример. Используйте 3-проводные отводящие клапаны: - ФАЗА РАЗМЫКАНИЯ 230 В - ФАЗА...
  • Página 377 FORCE W - Электрические соединения После монтажа будет необходимо выполнить необходимые электрические подключения, как показано на электрической схеме. Вслед за этим выполните конфигурацию блока управления согласно указаниям соответствующего параграфа. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 L _ N L _ N L _ N...
  • Página 378 FORCE W Спецификация (рис. 51 и рис. 52) B = НЕЙТРАЛЬНАЯ ФАЗА Комнатный термостат 1-й зоны (со смесительным клапаном) C = ФАЗА ЗАМЫКАНИЯ Комнатный термостат 2-й зоны (со смесительным 317a Предохранительный термостат 1-й зоны (со клапаном) смесительным клапаном) Комнатный термостат 3-й зоны (прямого контура) 317b Предохранительный...
  • Página 379: Газовые Соединения

    FORCE W 2.4 Газовые соединения Перед выполнением подключения удостоверьтесь, что котел отрегулирован для работы на имеющемся в Вашей магистрали газе и тщательно прочистите все газовые трубы для удаления остаточных загрязнений или посторонних включений, могущих помешать правильной работе агрегата. Газ подключается к соответствующему патрубку (см. рис. 82 ) с соблюдением действующих норм, с использованием жесткой металлической...
  • Página 380 FORCE W Термостат комнатной температуры ВНИМАНИЕ: ТЕРМОСТАТ КОМНАТНОЙ ТЕМПЕРАТУРЫ ДОЛЖЕН БЫТЬ УСТРОЙСТВОМ С КОНТАКТАМИ НЕ ПОД НАПРЯЖЕНИЕМ. ПРИ ПОДАЧЕ НАПРЯЖЕНИЯ В НА КЛЕММЫ ТЕРМОСТАТА КОМНАТНОЙ ТЕМПЕРАТУРЫ ПОВЛЕЧЕТ ЗА СОБОЙ НЕПОДЛЕЖАЩЕЕ РЕМОНТУ ПОВРЕЖДЕНИЕ ЭЛЕКТРОННОЙ ПЛАТЫ. При подключении регуляторов комнатной температуры с повременной программой...
  • Página 381: Возможные Неисправности

    FORCE W Максимально допустимые нагрузки: • Циркуляционный насос отопления: 230 В пер. тока, макс. 0,8 A = 0,6 • 3-ходовой клапан: 230 В пер. тока, макс. 0,8 A = 0,6 в течение максимум 1 минуты, 0,4 A постоянно • Тревога: 230 В пер. тока, макс. 0,8 A = 0,6 Для...
  • Página 382 FORCE W Каскадное подключение генераторов: прямой контур отопления и контур ГВС с циркуляционным насосом Принципиальная схема Электроника котла может управлять максимум 6 модулями. В примере приведены 3 модуля. рис. 57 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 383 FORCE W Электрические соединения После монтажа будет необходимо выполнить необходимые электрические подключения, как показано на электрической схеме. Вслед за этим выполните конфигурацию блока управления согласно указаниям соответствующего параграфа. 300M 300S 9 10 11 12 13 14 15 16 17 18 9 10 11 12 13 14 15 16 17 18 SLAVE 1 MASTER...
  • Página 384 примере показано подключение лампы 230 В пер. тока. «Дополнительные схемы каскадных, гидравлических и электрических подключений вы можете найти на сайте www.ferroli.com в разделе, посвященном продукции для ЖИЛОГО СЕКТОРА, котлам, FORCE W а также загрузить техническую документацию, содержащую все характеристики установки и конфигурации, из папки РУКОВОДСТВА: РУКОВОДСТВО...
  • Página 385: Дымоходы

    FORCE W 2.6 Дымоходы КОТЛЫ ДОЛЖНЫ УСТАНАВЛИВАТЬСЯ В ПОМЕЩЕНИЯХ, ОТВЕЧАЮЩИХ ОСНОВНЫМ ТРЕБОВАНИЯМ К ВЕНТИЛЯЦИИ. В ПРОТИВНОМ СЛУЧАЕ СУЩЕСТВУЕТ ОПАСНОСТЬ УДУШЬЯ ИЛИ ИНТОКСИКАЦИИ. ПРОЧИТАЙТЕ ИНСТРУКЦИИ ПО УСТАНОВКЕ И ТЕХНИЧЕСКОМУ ОБСЛУЖИВАНИЮ ПЕРЕД УСТАНОВКОЙ АГРЕГАТА. СОБЛЮДАЙТЕ ТАКЖЕ УКАЗАНИЯ ПРОЕКТНОЙ ДОКУМЕНТАЦИИ. ПРИ ДАВЛЕНИИ ВНУТРИ ДЫМООТВОДНЫХ ТРУБ ВЫШЕ 200 ПА ИСПОЛЬЗОВАНИЕ...
  • Página 386 ТРУБА 0,5 М с внешн./внутр. резьбой Ø100 КОЛЕНО 90° КОЛЕНО 45° ОГОЛОВОК Примеры расчетов FORCE W 60: имеющийся напор 77 Па Ø Ø 5 метров ТРУБЫ 80 + 3 КОЛЕНА 80 = (5 x 4,8) + (3 x 10)= 55<77 = OK Ø...
  • Página 387: Подсоединение Трубы Для Слива Конденсата

    FORCE W Любые горизонтальные участки отвода дымовых газов должны иметь небольшой уклон в сторону котла, чтобы конденсат не вытекал наружу, вызывая капание. Перед выполнением монтажа проверьте по таблица 5, не будет ли превышена максимально допустимая длина дымохода, имея в виду, что каждому коаксиальному колену соответствует уменьшение длины в размере, указанном в следующей таблице...
  • Página 388: Уход И Техническое Обслуживание

    выполняться только квалифицированным персоналом с проверенным опытом (обладающим профессиональными техническими реквизитами, предусмотренными действующим законодательством), например персоналом Региональной службы технической поддержки клиентов. FERROLI снимает с себя всякую ответственность за травмы и/или материальный ущерб, нанесенный в результате несанкционированного вмешательства в конструкцию агрегата со стороны неквалифицированных и неуполномоченных лиц. 3.1 Регулировки...
  • Página 389 FORCE W • Для моделей W 60 и W 80 Отвинтите винты “B” и снимите блок «Вентури/газовый клапан» (рис. 66). Отвинтите винты “E” и замените газовое сопло “F” на сопло из комплекта переоборудования, поместив его внутрь прокладки “G”. Соберите компоненты и проверьте уплотнения (рис. 67). рис.
  • Página 390 FORCE W • Для моделей W 99, W 120 и W 150 Извлеките блок управления газовым клапаном (рис. 68). Отвинтите винты “C” (рис. 69), фиксирующие вентилятор, и извлеките блок (рис. 70). рис. 68 рис. 69 Отвинтите винты “E” и замените газовое сопло “F” на сопло из комплекта переоборудования, поместив его внутрь прокладки...
  • Página 391 FORCE W • Для всех моделей Измените параметр, относящийся к типу газа, выполняя следующие действия. Войдите в экранное окно, показанное на рис. 72, следуя по маршруту "МЕНЮ ПОЛЬЗОВАТЕЛЯ Техническое обслуживание Тестовый режим Выбор типа газа”. Нажмите на контекстные клавиши 1 и 2, чтобы выбрать тип газа. Подтвердите...
  • Página 392 FORCE W рис. 73- Максимальная регулировка моделей W 60 и W 80 рис. 74- Минимальная регулировка моделей W 60 и W 80 рис. 75- Максимальная и минимальная регулировка моделей W 99, W 120 и W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 393 FORCE W Активация тестового режима TEST Войдите в окно, изображенное на рис. 76, двигаясь в меню по маршруту "МЕНЮ ПОЛЬЗОВАТЕЛЯ Обслуживание Режим тестирования Режим тестирования". Котел включается, постепенно достигая максимальной мощности отопления (Range Rated), которая задается в соответствии с указаниями из следующего параграфа. На...
  • Página 394 FORCE W МЕНЮ ТЕХНИКА ДОСТУП К СЕРВИСНОМУ МЕНЮ И ИЗМЕНЕНИЕ ПАРАМЕТРОВ ДОЛЖНЫ ВЫПОЛНЯТЬСЯ ТОЛЬКО КВАЛИФИЦИРОВАННЫМ ПЕРСОНАЛОМ. Доступ в меню «Техника» возможен только после ввода кода 4 1 8. Он действует в течение 15 минут. Меню «Параметры - Конфигурация» Доступно 16 параметров, обозначенных буквой “b”, которые не могут редактироваться с устройства дистанционного управления...
  • Página 395 FORCE W Параметр Описание Диапазон W 60 W 80 W 99 W 120 W 150 Время ожидания отопления 0-10 минут Пост-циркуляция в системе отопления 0-255 минут Режим работы насоса 0-3 Стратегия работы Мин. скорость насоса с регулируемой производительностью 0-100% Скорость запуска насоса с регулируемой производительностью 0-100% Макс.
  • Página 396 FORCE W Меню «Параметры – Тип системы» Имеется 23 параметра, обозначенные буквой “P”; эти параметры не могут редактироваться с устройства дистанционного управления с таймером. Параметр Описание Диапазон W 60 W 80 W 99 W 120 W 150 0 = Нормальный запрос на отопление 1 = Запрос...
  • Página 397: Ввод В Эксплуатацию

    FORCE W 3.2 Ввод в эксплуатацию Контрольные операции, которые следует выполнять перед первым розжигом, а также после проведения технического обслуживания, во время которого котел отсоединялся от сетей питания, или работ на защитных устройствах или деталях котла: Перед включением котла • Откройте...
  • Página 398: Техническое Обслуживание

    FORCE W 3.3 Техническое обслуживание ПРЕДУПРЕЖДЕНИЯ И МЕРЫ ПРЕДОСТОРОЖНОСТИ ВСЕ ОПЕРАЦИИ ПО ТЕХНИЧЕСКОМУ ОБСЛУЖИВАНИЮ ИЛИ ЗАМЕНЕ КОТЛА ДОЛЖНЫ ВЫПОЛНЯТЬСЯ СПЕЦИАЛИЗИРОВАННЫМ ПЕРСОНАЛОМ С ПОДТВЕРЖДЕННОЙ КВАЛИФИКАЦИЕЙ. Перед выполнением любых операций внутри котла отключите электропитание и закройте газовый вентиль, установленный перед котлом. В противном случае может возникнуть риск взрыва, электрического...
  • Página 399 FORCE W Открытие передней панели Некоторые компоненты внутри котла могут достигать высоких температур, и поэтому вызывать серьезные ожоги.Перед выполнением любых операций дождитесь, пока эти компоненты остынут, или наденьте подходящие перчатки. Чтобы снять кожух котла: 1. Отвинтите винты A (см. рис. 78). 2.
  • Página 400 FORCE W Внеплановое техническое обслуживание и замена компонентов Замена электрода Чистка теплообменника cod. 3541V232 - Rev 00 - 08/2021...
  • Página 401: Устранение Неисправностей

    FORCE W 3.4 Устранение неисправностей Диагностика Котел оснащен современной системой самодиагностики. В случае сбоя в работе котла на дисплее появляется код неисправности, а в случае каскадного подключения - номер модуля. • Существуют неполадки, вызывающие постоянную блокировку, которую можно сбросить нажатием на секунду кнопки OK или...
  • Página 402 FORCE W Код неисправн Неисправность Возможная причина Способ устранения ости Индикация перегрева датчика отопления 1 (подача) Недостаточная циркуляция воды в системе Проверьте циркуляцию воды (отображается только в меню History) Индикация перегрева датчика на обратном трубопроводе Недостаточная циркуляция воды в системе Проверьте...
  • Página 403 FORCE W Код неисправн Неисправность Возможная причина Способ устранения ости Защита при разнице Недостаточная циркуляция в котле Проверьте циркуляцию воды в котле/системе температур > 21° между датчиком в Неправильное положение датчика в контуре контуре подачи и Проверьте целостность датчика подачи предохранительным...
  • Página 404: Характеристики И Технические Данные

    FORCE W 4. Характеристики и технические данные Обозначения cap. 4 "Характеристики и технические данные" Подвод газа - Ø 3/4" Подача в систему - Ø 1" 1/2 Возврат из системы - Ø 1" 1/2 Предохранительный клапан Вентилятор Циркуляционный насос системы отопления (не входит...
  • Página 405: Размеры И Соединения

    FORCE W 4.1 Размеры и соединения рис. 79- Вид спереди рис. 80- Вид сбоку рис. 81- Вид сверху рис. 82- Вид сверху cod. 3541V232 - Rev 00 - 08/2021...
  • Página 406: Общий Вид

    4.2 Общий вид рис. 84- Общий вид, мод. FORCE W 99 и FORCE W 120 рис. 83- Общий вид, мод. FORCE W 60 и FORCE W 80 рис. 85- Общий вид, мод. FORCE W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 407: Гидравлический Контур

    FORCE W 4.3 Гидравлический контур рис. 86- Гидравлический контур cod. 3541V232 - Rev 00 - 08/2021...
  • Página 408: Таблица Технических Данных

    FORCE W 4.4 Таблица технических данных В правом столбце указывается сокращение, используемое на табличке с техническими данными. cod. 3541V232 - Rev 00 - 08/2021...
  • Página 409 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 410: Диаграммы

    FORCE W 4.5 Диаграммы Потеря нагрузки рис. 87- Диаграмма потери нагрузки для моделей FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 рис. 88- Диаграмма потери нагрузки для моделей FORCE W 150 Расход - м...
  • Página 411: Электрические Схемы

    FORCE W 4.6 Электрические схемы Спецификацию рисунков можно найти на page 404. ВНИМАНИЕ: Перед подключением комнатного термостата или пульта ДУ с таймером снимите перемычку на клеммной колодке. ВНИМАНИЕ: для подключения 3-ходового клапана (клеммы 13–14–15) см. схемы рис. 89 и рис. 90. рис.
  • Página 412 FORCE W рис. 92- Электрическая схема моделей FORCE W 60 и FORCE W 80 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 413 FORCE W рис. 93- Электрическая схема моделей FORCE W 99, FORCE W 120 и FORCE W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 414 FORCE W • Należy uważnie przeczytać ostrzeżenia zawarte w • W celu zagwarantowania sprawnego działania niniejszej instrukcji, ponieważ zawiera ona ważne urządzenia, niezbędne jest przeprowadzanie okre- wskazówki dotyczące bezpieczeństwa podczas sowej konserwacji przez wykwalifikowany personel. montażu, eksploatacji i konserwacji. • Urządzenie można stosować...
  • Página 415 FORCE W 1 Instrukcja obsługi ........................ 416 1.1 Wprowadzenie............................ 416 1.2 Panel sterowania ..........................416 1.3 Zapłon i wyłączanie ..........................420 1.4 Regulacje ............................421 2 Instalacja..........................429 2.1 Zalecenia ogólne ..........................429 2.2 Miejsce instalacji ..........................429 2.3 Podłączenia hydrauliczne........................429 2.4 Podłączenie gazu ..........................
  • Página 416: Instrukcja Obsługi

    1.1 Wprowadzenie Szanowny Kliencie, Dziękujemy za wybranie FORCE W, kotła naściennego z zamkniętą komorą spalania marki FERROLI o zaawan- sowanym projekcie, awangardowej technologii oraz wysokiej niezawodności i jakości wykonania. Prosimy o uważne przeczytanie niniejszej instrukcji, ponieważ zawiera ona ważne informacje dotyczące bezpieczeństwa instalacji, użytkowania oraz konserwacji.
  • Página 417 FORCE W Przyciski bezpośrednie Przyciski bezpośrednie (poz. 8, 9, 10 - wygląd 1) zawsze mają taką samą funkcję. Przyciski nawigacji/menu Przyciski nawigacji/menu (poz. 5, 6, 7, 11, 12, 13 - wygląd 1) służą do przechodzenia pomiędzy różnymi menu na pa- nelu sterowania.
  • Página 418 FORCE W KONSERWACJA Patrz wygląd 76 Tryb TEST Patrz wygląd 72 Tryb TEST Wybór rodzaju gazu Tryb test kaskadowy Patrz “Informacje serwisowe” on page 426 Informacje serwisowe Patrz “Data interwencji serwisowej” on page 426 Data interwencji serwisowej USTAWIENIA Patrz wygląd 8 Język Jednostka miary Patrz wygląd 9...
  • Página 419 FORCE W Wyłączenie zasobnika (economy) Użytkownik może wyłączyć ogrzewanie / utrzymywa- nie temperatury w zasobniku. W razie wyłączenia ciepła woda użytkowa nie będzie dostępna. Użytkow- nik może wyłączyć zasobnik (tryb ECO) poprzez na- ciśnięcie przycisku eco / comfort (poz. 10 - wygląd 1). 23°C 32°C W trybie ECO na wyświetlaczu pojawia się...
  • Página 420: Zapłon I Wyłączanie

    FORCE W 1.3 Zapłon i wyłączanie Zapłon kotła Nacisnąć przycisk włączenia/wyłączenia (poz. 14 - wygląd 1). Po naciśnięciu przycisku kontekstowego 1 można wy- brać żądany język. Zatwierdzić wybór przyciskiem „OK”. Po naciśnięciu przycisku kontekstowego 3 można pr- zerwać tryb FH. Jeśli nie zostanie dokonany żaden wybór spośród opi- Display v.0X sanych powyżej, przejść...
  • Página 421: Regulacje

    FORCE W Wyłączenie kotła Na ekranie głównym (Home) nacisnąć przycisk kon- Aby całkowicie odłączyć urządzenie od zasilania elek- tekstowy i potwierdzić przyciskiem trycznego, nacisnąć przycisk 14 wygląd 1. Gdy kocioł zostaje wyłączony, karta elektroniczna jest nadal zasilana elektrycznie. Wyłączone jest działanie instalacji c.w.u. (z zainsta- lowanym opcjonalnym zasobnikiem) oraz c.o.
  • Página 422 FORCE W Redukcja temperatury c.o. Wejść do menu „Temp Regulacja Redukcja”, aby CH setpoint reduction zmienić temperaturę w zakresie od minimum 0°C do maksimum 50°C. Potwierdzić przyciskiem OK. Parametr ten jest stosowany wyłącznie wte- dy, kiedy włączone jest programowanie cza- sowe.
  • Página 423 FORCE W Wybrać dzień (wygląd 17) lub przedział dni do zaprogramowania (wygląd 18), a następnie potwierdzenie za pomocą przycisku OK. Scheduler Set Scheduler Set Wednesday Monday Thursday Tuesday Friday Wednesday Saturday Thursday Sunday Friday Monday-Sunday Saturday Monday-Friday Sunday Saturday-Sunday Monday-Sunday to confirm to confirm wygląd 18...
  • Página 424 FORCE W Nacisnąć przycisk nawigacji 7 i za pomocą przycisków Scheduler Set kontekstowych 1 i 2 ustawić tryb pracy podczas pie- rwszego przedziału godzinowego (wygląd 21) 06:00 - 16:00 --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- --:-- - --:-- Copy to the Next Day Save &...
  • Página 425 FORCE W Aby przywrócić program godzinowy do war- Scheduler Set tości fabrycznych, nacisnąć przycisk kon- tekstowy 3 w menu Program godzinowy Monday (wygląd 26) i potwierdzić przyciskiem OK. Tuesday Wednesdey Thursday Friday Saturday Sunday Monday-Sunday to confirm wygląd 26 Dwa programy godzinowe Ogrzewania i Ciepłej wody użytkowej są niezależne również w przypadku Pr- zywrócenia do wartości fabrycznej.
  • Página 426: Informacje Serwisowe

    FORCE W Temperatura ustawiona w menu „Temp. Regulacja Zabezpieczenie przed bakteriami legionelli” NIE powinna być wyższa niż maksymalna temperatura regulacji c.w.u, ustawiona za pomocą parametru P19 w MENU TECHNICZNYM. Jeśli w układzie zainstalowano pompę obiegową do obiegu wody podczas funkcji zabezpieczenia przed bakteriami legionelli, konieczne jest ustawienie parametru b08 na 1.
  • Página 427 FORCE W Krzywa kompensacji i przesunięcie /offset/ krzywej Wejść do menu Płynnej temperatury. Wyregulować OTC Curve 1 żądaną krzywą w zakresie od 1 do 10 w zależności od charakterystyki (wygląd 30) za pomocą parametru „Krzywa 1” i potwierdzić przyciskiem OK. Gdy krzywa jest ustawiona na 0, regulacja płynnej temperatury jest wyłączona.
  • Página 428 FORCE W Temperatura Zewnętrzna Ogrzewanie WYŁ. Wejść do menu „Temp Zew. Ogrz. Wył.”, aby włączyć funkcję: pomiędzy 7°C a 30°C. Jeśli funkcja ta jest włączona, będzie ona zawsze wyłączała żądanie ogrzewania w sytuacji, kiedy temperatura zmier- zona przez sondę zewnętrzną jest wyższa od wartości zaprogramowanej. Żądanie ogrzewania jest ponownie włączane, gdy temperatura zmierzona przez sondę...
  • Página 429: Instalacja

    FORCE W 2. Instalacja 2.1 Zalecenia ogólne INSTALACJA KOTŁA MUSI BYĆ WYKONYWANA WYŁĄCZNIE PRZEZ WYKWALIFIKOWANY PERSONEL, ZGOD- NIE Z WSZYSTKIMI INSTRUKCJAMI PODANYMI W NINIEJSZEJ INSTRUKCJI TECHNICZNEJ, PRZEPISAMI AK- TUALNEGO PRAWA, ZALECENIAMI NORM KRAJOWYCH I LOKALNYCH ORAZ PRZEPISAMI WŁAŚCIWEGO WYKONAWSTWA. 2.2 Miejsce instalacji Generator powinien być...
  • Página 430 FORCE W Pompa obiegowa wysokiej wydajności (opcja) Ustawienie fabryczne jest odpowiednie dla wszystkich instalacji; jednakże za pomocą przełącznika prędkości (patrz wygląd 33) można ustawić inną strategię działania w zależności od parametrów instalacji. 1 2 3 wygląd 33 Ustawienie Dp-v Ustawienie Dp- c Ustawienie Wysokość...
  • Página 431 FORCE W Charakterystyka wody w układzie Przed przystąpieniem do zainstalowania generatora FORCE W należy odpowiednio wyczyścić instalację (zarówno nową, jak i istniejącą), aby usunąć ewentualne pozostałości po instalacji, rozpuszczalniki, błoto i ogólne zanieczyszc- zenia, które mogą obniżać sprawność zabiegów z użyciem środków ochronnych. Stosować neutralne środki czyszczące, które nie są...
  • Página 432 FORCE W Zawsze sprawdzać stężenie produktu po każdym włączeniu, a także cyklicznie, co najmniej raz w roku. Przeprowadzenie kontroli zlecać wykwalifikowanemu se- rwisantowi z naszej sieci autoryzowanych serwisów technicznych. Tabela 2- Środki chemiczne wskazane jako odpowiednie i dostępne w naszej sieci Autoryzowanych Serwisów Technicznych Produkty alternatywne typu Senti- Opis...
  • Página 433 FORCE W System zabezpieczający przed zamarzaniem, płyny przeciwzamarzaniowe, dodatki i inhibitory Kocioł jest wyposażony w system zabezpieczenia przez zamarzaniem, który włącza kocioł w trybie centralnego ogr- zewania, gdy temperatura wody na zasilaniu instalacji spada poniżej 5°C. Urządzenie nie jest aktywne, jeśli odłączone jest zasilanie elektryczne oraz/lub gazowe.
  • Página 434 FORCE W Przykłady obwodów hydraulicznych W przykładach opisanych poniżej konieczne może MENU być sprawdzenie/modyfikacja niektórych parametrów. W tym celu należy wejść do menu serwisanta. USER Na ekranie głównym (Home) nacisnąć przycisk Menu główne (poz. 12 - wygląd 1). TECHNICIAN Wejść do menu „Serwisant”. W tym celu nacisnąć pr- zycisk kontekstowy 2 (poz.
  • Página 435: Podłączenia Elektryczne

    FORCE W Dwa bezpośrednie obwody ogrzewania - Schemat główny wygląd 42 - Podłączenia elektryczne Po zainstalowaniu konieczne będzie wykonanie podłączeń elektrycznych zgodnie ze schematem elektrycznym. Następnie należy skonfigurować centralkę zgodnie z opisem w odnośnym rozdziale. Legenda (wygląd 42 i wygląd 43) 9 10 11 12 13 14 15 16 17 18 Termostat pokojowy strefy 1 (bezpośrednia) 72b Termostat pokojowy strefy 2 (bezpośrednia)
  • Página 436 FORCE W - Parametry Każda instalacja wymaga innego ustawienia parametrów. Przeprowadzić poniższą procedurę. Menu „Rodzaj instalacji” Zmienić parametr P.01 w menu „Rodzaj instalacji” na 4. - Funkcjonalności opcjonalne Oprócz podłączeń elektrycznych przedstawionych na poprzednim rysunku (koniecznych przy tej konfiguracji instalacji) istnieją...
  • Página 437 FORCE W Obwód ogrzewania bezpośredniego oraz obwód ciepłej wody użytkowej z pompą obiegową - Schemat główny wygląd 45 - Podłączenia elektryczne Po zainstalowaniu konieczne będzie wykonanie podłączeń elektrycznych zgodnie ze schematem elektrycznym. Następnie należy skonfigurować centralkę zgodnie z opisem w odnośnym rozdziale. Legenda (wygląd 45 i wygląd 46) 9 10 11 12 13 14 15 16 17 18 Termostat pokojowy strefy 1 (bezpośrednia)
  • Página 438 FORCE W - Parametry Każda instalacja wymaga innego ustawienia parametrów. Przeprowadzić poniższą procedurę. Menu „Parametry - Konfiguracja” Sprawdzić/Zmienić parametr b02 w menu „Parametry transparentne” na 8. Sprawdzić/Zmienić parametr b08 w menu „Parametry transparentne” na 1. Sprawdzić/Zmienić parametr b04, b05 i b06 w menu „Parametry transparentne” odpowiednio do wartości podanych w tabeli ”Menu Parametry - Konfiguracja”...
  • Página 439 FORCE W Obwód ogrzewania bezpośredniego oraz obwód ciepłej wody użytkowej z zaworem rozdzielczym (3- żyłowy) - Schemat główny Użyć zaworu rozdzielczego 3-żyłowego: - FAZA OTWARCIA 230V - FAZA ZAMKNIĘCIA 230V - NEUTRALNY o czasach przełączania (od całkowitego zamknięcia do całkowitego otwarcia) nie dłuższych niż 90 sekund. wygląd 48 - Podłączenia elektryczne Po zainstalowaniu konieczne będzie wykonanie podłączeń...
  • Página 440 FORCE W Legenda (wygląd 48 i wygląd 49) Pompa obiegowa ogrzewania Obwód zasobnika Termostat pokojowy strefy 1 (bezpośrednia) Tłoczenie 138 Sonda zewnętrzna Powrót 155 Sonda zasobnika K1 - K2cewka 230 Vac , < 2,2 VA 348 Zawór 3-drożny (z trzema żyłami) styk 230Vac , >...
  • Página 441 FORCE W Dwa obwody ogrzewania mieszane, obwód ogrzewania bezpośredniego oraz obwód ciepłej wody użytkowej z pompą obiegową - Schemat główny Karta sterowania strefą FZ4B może zarządzać różnymi typologami instalacji. Poniżej przedstawiono jeden przykład. Użyć zaworu rozdzielczego 3-żyłowego: - FAZA OTWARCIA 230V - FAZA ZAMKNIĘCIA 230V - NEUTRALNY o czasach przełączania (od całkowitego zamknięcia do całkowitego otwarcia) nie dłuższych niż...
  • Página 442 FORCE W - Podłączenia elektryczne Po zainstalowaniu konieczne będzie wykonanie podłączeń elektrycznych zgodnie ze schematem elektrycznym. Następnie należy skonfigurować centralkę zgodnie z opisem w odnośnym rozdziale. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 L _ N L _ N L _ N...
  • Página 443: A = Faza Otwarcia

    FORCE W Legenda (wygląd 51 i wygląd 52) 72a Termostat pokojowy strefy 1 (mieszana) B = NEUTRALNY 72b Termostat pokojowy strefy 2 (mieszana) C = FAZA ZAMKNIĘCIA 72c Termostat pokojowy strefy 3 (bezpośrednia) 317a Termostat bezpieczeństwa strefy 1 (mieszana) 130 Pompa obiegowa zasobnika 317b Termostat bezpieczeństwa strefy 2 (mieszana) 138 Sonda zewnętrzna 318a Pompa obiegowa strefy 1 (mieszana)
  • Página 444: Podłączenie Gazu

    FORCE W 2.4 Podłączenie gazu Przed podłączeniem gazu sprawdzić, czy urządzenie jest przystosowane do działania z dostępnym typem paliwa i dokładnie przeczyścić wszystkie rury ga- zowe instalacji, aby usunąć ewentualne pozostałości mogące negatywnie wpłynąć na pracę kotła. Gaz należy podłączyć do właściwego przyłącza (patrz wygląd 82) zgodnie z obowiązującymi przepisami, za pomocą sztywnej rury metalowej lub giętkiego przewodu o ściance ciągłej ze stali nierdzewnej, wstawiając zawór gazu pomiędzy instalację...
  • Página 445 FORCE W Podłączając zdalne sterowanie czasowe lub wyłącznik czasowy (timer) należy unikać podłączania zasilania tych urządzeń do ich styków przerywających. Ich za- silanie należy wykonać poprzez bezpośrednie podłączenie do sieci lub do baterii, zależnie od typu urządzenia. Sonda zewnętrzna (opcja) Podłączyć...
  • Página 446 FORCE W W przypadku podłączenia kaskadowego UWAGA: Elektronika kotła może obsługiwać maksymalnie 6 modułów. 1. Podłączyć moduły w taki sposób, jak to pokazano na wygląd 56 (przykład z 3 modułami) wygląd 56- Podłączenie kaskadowe A Moduł 1 C Moduł 3 B Moduł...
  • Página 447 FORCE W Generatory ułożone kaskadowo: obwód ogrzewania bezpośredniego oraz obwód ciepłej wody użytkowej z pompą obiegową Schemat główny Elektronika kotła może obsługiwać maksymalnie 6 modułów. W przykładzie jest 3. wygląd 57 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 448 FORCE W Połączenia elektryczne Po zainstalowaniu konieczne będzie wykonanie podłączeń elektrycznych zgodnie ze schematem elektrycznym. Następnie należy skonfigurować centralkę zgodnie z opisem w odnośnym rozdziale. 300M 300S 9 10 11 12 13 14 15 16 17 18 9 10 11 12 13 14 15 16 17 18 SLAVE 1 MASTER 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36...
  • Página 449 FORCE W Aby zarządzać płynna temperaturą, konieczne jest nabycie sondy zewnętrznej o numerze kat. 013018X0 W razie korzystania z sondy zasobnika (nie wchodzi w zakres dostawy) konieczne jest nabycie sondy NTC o numerze kat. 1KWMA11W (2 m) lub o numerze kat. 043005X0 (5 m) W razie korzystania z termostatu zasobnika (nie wchodzi w zakres dostawy) konieczne jest nabycie zestawu akcesoriów o numerze kat.
  • Página 450: Przewód Spalin

    FORCE W 2.6 Przewód spalin KOCIOŁ MUSI BYĆ ZAINSTALOWANY W MIEJSCACH, KTÓRE SPEŁNIAJĄ PODSTAWOWE WYMAGANIA WENTYLACJI. W INNYM PRZYPADKU ISTNIEJE NIEBEZPIECZEŃSTWO UDUSZENIA LUB ZATRUCIA. PRZED INSTALACJĄ URZĄDZENIA NALEŻY PRZECZYTAĆ INSTRUKCJĘ IN- STALACJI I KONSERWACJI. NALEŻY RÓWNIEŻ PRZESTRZEGAĆ INSTRUKCJI KONSTRUKCYJNYCH. W PRZYPADKU CIŚNIENIA WEWNĄTRZ RUR SPALINOWYCH POWYŻEJ 200 Pa NALEŻY OBOWIĄZKOWO STOSOWAĆ...
  • Página 451 KOŃCÓWKA Przykłady obliczania FORCE W 60; dostępna wysokość ciśnienia 77 Pa 5 metrów RURY Ø80 + 3 KOLANKA Ø80 = (5 x 4,8) + (3 x 10)= 55<77 = OK 8 metrów RURY Ø80 + 6 KOLANEK Ø80 = (8 x 4,8) + (6 x 10)= 100<77 = OK Przewód spalin...
  • Página 452: Podłączenie Spustu Kondensatu

    FORCE W Wszelkie poziome odcinki odprowadzające spaliny muszą być lekko pochylone w kierunku kotła, aby zapobiec ewen- tualnemu wypływowi skroplin na zewnątrz, co będzie powodem skapywania kondensatu. Przed przystąpieniem do instalacji sprawdzić w tabela 5, czy nie jest przekroczona maksymalna dopuszczalna długość, pamiętając, że każde kolanko współosiowe powoduje redukcję...
  • Página 453: Obsługa I Konserwacja

    (posiadający przewid- ziane przez obowiązującą normę zawodowe kompetencje techniczne) jak np. personel lokalnego serwisu technicznego. FERROLI nie ponosi żadnej odpowiedzialności za szkody majątkowe i/lub uszkodzenia cielesne powstałe na skutek inte- rwencji przy urządzeniu przez osoby bez kwalifikacji i upoważnienia.
  • Página 454 FORCE W • W przypadku modeli W 60 i W 80 Odkręcić śruby „B” i wyjąć podzespół „ Zwężka Venturiego/zawór gazu” (wygląd 66). Odkręcić śruby „E:, a następnie wymienić dyszę gazu „F: na dyszę dołączoną w zestawie przezbrojeniowym. Umieścić dyszę w uszczelce „G”. Zamontować z powrotem komponenty i sprawdzić szczelność (wygląd 67). wygląd 66- Modele W 60 i W 80 wygląd 67 cod.
  • Página 455 FORCE W • W przypadku modeli W 99, W 120 i W 150 Wyjąć centralkę zaworu gazowego (wygląd 68). Odkręcić śruby „C” (wygląd 69), które mocują wentylator, i wyjąć zespół (wygląd 70). wygląd 68 wygląd 69 Odkręcić śruby „E:, a następnie wymienić dyszę gazu „F: na dyszę dołączoną w zestawie przezbrojeniowym. Umieścić...
  • Página 456 FORCE W • We wszystkich modelach Zmienić parametr rodzaju gazu zgodnie z opisem poniżej. Wejść na ekran przedstawiony na wygląd 72, W tym celu przejść w menu ścieżkę „MENU UŻYTKOWNIKA Kon- serwacja Tryb TEST Wybór rodzaju gazu”. Nacisnąć przyciski kontekstowe 1 i 2, aby wybrać rodzaj gazu. Potwierdzić...
  • Página 457 FORCE W wygląd 73- Regulacja maksymalna modeli W 60 i W 80 wygląd 74- Regulacja minimalna modeli W 60 i W 80 wygląd 75- Regulacja maksymalna i minimalna modeli W 99, W 120 i W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 458 FORCE W Uruchomienie trybu TEST Wejść na ekran przedstawiony na wygląd 76, W tym celu przejść w menu ścieżkę „MENU UŻYTKOWNIKA Konse- rwacja Tryb TEST Tryb test”. Kocioł włącza się po osiągnięciu maksymalnej mocy ogrzewania (Range Rated) ustawionej zgodnie z opisem w następ- nym rozdziale w sposób stopniowy.
  • Página 459 FORCE W Wykres regulacji obciążenia cieplnego A = kW - B = Parametr karty elektronicznej wygląd 77 MENU SERWISANTA JEDYNIE WYKWALIFIKOWANY PERSONEL MOŻE UZYSKAĆ DOSTĘP DO MENU SERWISOWEGO ORAZ ZMIE- NIAĆ PARAMETRY. Dostęp do Menu Serwisanta jest możliwe dopiero po wpisaniu kodu 4 1 8. Jest ważne przez 15 minut. Menu Parametry - Konfiguracja Dostępnych jest 16 parametrów oznaczonych literą...
  • Página 460 FORCE W Parametr Opis Zakres W 60 W 80 W 99 W 120 W 150 Nie wprowadzono Maksymalna temperatury spalin 0-125 °C Wybór typu wentylatora Czas pracy zabezpieczenia przed zablokowaniem 0-20 sekund pompy Uwagi 1. Parametry o więcej niż jednym opisie mogą różnić się co do ich funkcji i/lub zakresu w stosunku do ustawienia pa- rametru podanego nawiasach.
  • Página 461 FORCE W Parametr Opis Zakres W 60 W 80 W 99 W 120 W 150 Przy B02 = 7 - Niewykorzystane Przy B02 = 8 - Zabezpieczenie przed bakteriami legionelli WŁ. - WYŁ. Przy B02 = 9 - Zabezpieczenie przed bakteriami legionelli WŁ.
  • Página 462: Uruchamianie

    FORCE W Parametr Opis Zakres W 60 W 80 W 99 W 120 W 150 P.15 0-10Vdc Napięcie minimalne (Sterowanie wg temperatury)** 0 ÷ 100°C 0-10Vdc Temperatura maksymalna (Sterowanie wg tempera- P.16 0 ÷ 100°C tury)** P.17 0-10Vdc Napięcie ogrzewania WYŁ. (Sterowanie wg mocy)** 0,1-10 Vdc P.18 0-10Vdc Napięcie ogrzewania WŁ.
  • Página 463: Konserwacja

    FORCE W • Upewnić się, że zużycie paliwa wskazywane przez licznik odpowiada podanemu w tabeli danych technicznych w sez. 4.4. • Sprawdzić prawidłowość zaprogramowania parametrów i wprowadzić ewentualne pożądane ustawienia indywidual- ne (krzywa kompensacji, moc, temperatury itp.). 3.3 Konserwacja WAŻNE INFORMACJE WSZYSTKIE PRACE KONSERWACYJNE I WYMIANY MUSZĄ...
  • Página 464 FORCE W Otwarcie panelu przedniego Niektóre komponenty wewnętrzne kotła mogą osiągać wysokie temperatury, które grożą poważnymi oparzeniami. Przed wykonaniem jakiejkolwiek czyn- ności należy odczekać, aż komponenty te ostygną lub ewentualnie założyć odpowiednie rękawice. Aby otworzyć obudowę kotła: 1. Odkręcić śruby A (patrz wygląd 78). 2.
  • Página 465 FORCE W Konserwacja nadzwyczajna oraz wymiana komponentów Wymiana elektrody Czyszczenie wymiennika cod. 3541V232 - Rev 00 - 08/2021...
  • Página 466: Rozwiązywanie Problemów

    FORCE W 3.4 Rozwiązywanie problemów Diagnostyka Kocioł jest wyposażony w zaawansowany system autodiagnostyczny. W razie nieprawidłowości w działaniu kotła na wyświetlaczu pojawi się kod usterki oraz - w przypadku połączenia kaskadowego - numer modułu. • Istnieją usterki, które powodują stałą blokadę. W celu przywrócenia pracy należy nacisnąć przycisk OK i przytrzy- mać...
  • Página 467 FORCE W Usterka Możliwa przyczyna Środki zaradcze usterki Uszkodzony czujnik Awaria czujnika ogr- Okablowanie zwarte Sprawdzić okablowanie lub wymienić czujnik zewania 1 (zasilanie) Instalacja elektryczna odłączona Uszkodzony czujnik Awaria czujnika Okablowanie zwarte Sprawdzić okablowanie lub wymienić czujnik powrotu Instalacja elektryczna odłączona Uszkodzony czujnik Awaria czujnika c.w.u.
  • Página 468: Dane I Parametry Techniczne

    FORCE W 4. Dane i parametry techniczne Legenda do rysunku cap. 4 "Dane i parametry techniczne" Wlot gazu - 3/4” Wymiennik z aluminium Ø Zasilanie instalacji - 1” 1/2 Czujnik bezpieczeństwa Ø Powrót z instalacji - 1” 1/2 Przyłącze spustowe kondensatu Ø...
  • Página 469: Wymiany I Złącza

    FORCE W 4.1 Wymiany i złącza wygląd 79- Widok z przodu wygląd 80- Widok z boku wygląd 81- Widok z góry wygląd 82- Widok z góry cod. 3541V232 - Rev 00 - 08/2021...
  • Página 470: Widok Ogólny

    4.2 Widok ogólny wygląd 84- Widok ogólny mod. FORCE W 99 i FORCE W 120 wygląd 83- Widok ogólny mod. FORCE W 60 i FORCE W 80 wygląd 85- Widok ogólny mod. FORCE W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 471: Obwód Hydrauliczny

    FORCE W 4.3 Obwód hydrauliczny wygląd 86- Obwód hydrauliczny cod. 3541V232 - Rev 00 - 08/2021...
  • Página 472: Tabela Danych Technicznych

    FORCE W 4.4 Tabela danych technicznych W kolumnie prawej podane są skróty stosowane na tabliczce znamionowej. cod. 3541V232 - Rev 00 - 08/2021...
  • Página 473 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 474: Tabele Erp

    FORCE W 4.5 Tabele ErP cod. 3541V232 - Rev 00 - 08/2021...
  • Página 475 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 476 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 477 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 478 FORCE W cod. 3541V232 - Rev 00 - 08/2021...
  • Página 479: Wykresy

    4.6 Wykresy Straty ciśnienia wygląd 87- Wykres strat ciśnienia w modelach FORCE W 60 - FORCE W 80 - FORCE W 99 - FORCE W 120 wygląd 88- Wykres strat ciśnienia w modelach FORCE W 150 Natężenie przepływu - m...
  • Página 480: Schematy Elektryczne

    FORCE W 4.7 Schematy elektryczne Legenda do rysunków znajduje się na page 468. WAŻNE: Przed podłączeniem termostatu pokojowego lub zdalnego panelu pokojowego zdjąć mostek w skrzyn- ce zaciskowej. UWAGA: W przypadku podłączania zaworu 3-drożnego (zaciski 13 - 14 - 15) postępować zgodnie z zaleceniami podanymi na schematach wygląd 89 i wygląd 90.
  • Página 481 FORCE W wygląd 92- Schemat elektryczny modeli FORCE W 60 oraz FORCE W 80 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 482 FORCE W wygląd 93- Schemat elektryczny modeli FORCE W 99, FORCE W 120 oraz FORCE W 150 cod. 3541V232 - Rev 00 - 08/2021...
  • Página 484 Fabbricato in Italia - Fabricado en Italia - Организация, уполномоченная производителем на принятие претензий от потребителя: ИЗАО "ФерролиБел". УНП 690655161. Адрес: улица Заводская, дом 45, город Фаниполь, Дзержинский район, Минская область, Республика Беларусь, 222750. Телефон: +375 (17) 169-79-49, адрес электронной почты: [email protected].