- Optional functions
As well as the electrical connections of the previous figure (required for this system con-
figuration) there are options that do not require settings.
4
5
6
7
8
9
302
FUSIBILE
Esterno
L
FUSIBILE
3.15A
L
N
T
300
N
Key
139 Remote Control: it can be installed in place of 72 to manage the request of the 1st zone (direct)
300 Burner On indication (voltage-free output): the example shows the connection of an hour counter at 230Vac
301 Fault indication (voltage-free contact output): the example shows the connection of a lamp at 230Vac
302 Remote reset input (230Vac): the example shows the connection of a double-pole switch at 230Vac, allowing
the resetting of a block type fault
357 Fault indication (230Vac): the example shows the connection of a lamp at 230Vac
Two mixed heating circuits, one direct heating circuit and one DHW circuit with
circulating pump
- Schematic diagram
The zone control card FZ4B can manage different types of systems. An example is given.
Use diverter valves with 3 wires:
- OPENING PHASE 230V
- CLOSING PHASE 230V
- NEUTRAL
with switching times (from all closed to all open) of not more than 180 seconds.
FZ4B
138
M
I*
RA
RB
- Electrical connections
After installation, carry out the necessary electrical connections as shown on the wiring
diagram.
Then configure the controller as described in the specific section.
54
EN
10 11 12
13 14 15
28 29 30 31 32 33
16 17 18 19 20 21 22 23 24 25 26 27
301
139
fig. 23
72/139a
72/139b
72/139c
317a
317b
318a
318b
318c
319a
319b
315a
315b
M
M
a
b
c
fig. 24
cod. 3541A282 - Rev. 01 - 02/2013
4
L
FUSIBILE
3.15A
34 35 36
L
357
X01
X02
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
317a
N
L
FUSIBILE
Esterno
Key
72a Room thermostat 1st zone (mixed)
72b Room thermostat 2nd zone (mixed)
72c Room thermostat 3rd zone (direct)
130 Hot water tank circulating pump
138 External probe
139a Remote Timer Control 1st zone (mixed)
139b Remote Timer Control 2nd zone (mixed)
139c Remote Timer Control 3rd zone (direct)
155 Hot water tank probe
300 Legionella protection circulating pump
155
315a Mixing valve 1st zone (mixed)
A = OPENING PHASE
300
B = NEUTRAL
C = CLOSING PHASE
315b Mixing valve 2nd zone (mixed)
A = OPENING PHASE
B = NEUTRAL
130
C = CLOSING PHASE
I* ISPESL safety devices (When required - not supplied)
d
To manage sliding temperature it is necessary to purchase the external probe accessory code 013018X0
If a hot water tank probe (not supplied) is used, it is necessary to purchase the NTC probe accessory code
1KWMA11W (2 mt.) or code 043005X0 (5 mt.)
If a hot water tank thermostat (not supplied) is used, it is necessary to purchase the kit accessory code
013017X0 (to be connected in place of the Hot Water Tank Probe)
- Parameters
Each system requires a different parameterisation. Follow the access procedure given
below.
"Service Menu"
The card Service Menu is accessed by pressing the Reset button for 10 seconds.
Press the Heating buttons to select "tS", "In", "Hi" or "rE"
"tS" means Transparent Parameters Menu, "In" means Information Menu, "Hi" means
History Menu, "rE" means History Menu Reset.
Select "tS" and press the Reset button.
Check/Change parameter P02 of the "Transparent Parameters Menu" to 5.
Check/Change parameter P27 of the "Transparent Parameters Menu" to 1.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
der. To modify the value of a parameter just press the DHW buttons; the change will be
automatically saved.
Press the Reset button to return to the Service Menu. Press the Reset button for 10 sec-
onds to exit the card Service Menu.
QUADRIFOGLIO
5
6
7
8
9
10 11 12
13 14 15
L
N
FUSIBILE
Esterno
300
130
16 17 18 19 20 21 22 23 24 25 26 27
N
N
FZ4B
L _ N
L _ N L _ N
L _ N
L
L
L L
BUS RT1 RT2 RT3
X03
X09
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
A B
C
A B C
317b
318a
315a
315b
139a
318b
318c
ALTA TENSIONE
BASSA TENSIONE
fig. 25
317a Safety thermostat 1st zone (mixed)
317b Safety thermostat 2nd zone (mixed)
318a 1st zone (mixed) circulating pump
318b 2nd zone (mixed) circulating pump
318c 3rd zone (direct) circulating pump
319a Delivery sensor 1st zone (mixed)
319b Delivery sensor 2nd zone (mixed)
M Delivery
RA High Temperature Return
RB Low Temperature Return
a 1st zone (mixed)
b 2nd zone (mixed)
c 3rd zone (direct)
d Hot water tank circuit
28 29 30 31 32 33
34 35 36
155
X15
T1
T2
T3 T4
BLR
X10
X11
X12
X13
X14
72b
72a
72c
319a
319b
138
139b
139c