6.
Loosen 2off flange sockets (M4x6), and adjust the position of the Adjuster Plate
(R) or (L).
Make the adjustment so that the width indicated in the diagram below is the
diameter of the coin minus 0.5 to 0.6mm.
Note: Measure the width at both ends of the acceptor to ensure that the
Adjuster Plate is parallel.
Measuring locations
7.
To confirm the adjustment, arrange coins inside the Coin Acceptor Assy, and
make sure that, with the Adjuster Plate at the bottom, the coins overlap the
Acceptor Base by 0.5 to 0.6mm.
Overlapping section of acceptor base (R) (or (L)) and coins
Coin
8.
After adjustment, tighten the 2off flange sockets (M4x6), and reassemble in the
machine in the reverse order of removal.
Flange sockets (M4 x 6)
Adjuster plate (R) (or (L))
Page 49
Adjuster plate (R)
(or (L))