Haier HMV1640 Instrucciones De Instalación página 20

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

REMOVE THE BLOWER PLATE
1. Remove the screw that fastens the blower plate to the microwave.
2. Lift off the blower plate. Set the screw aside.
a
INSTALL MOUNTING PLATE
NOTE: At least one wood screw must be used to attach the plate to a wall stud.
1. Remove the toggle wings from the bolts.
2. Insert the bolts into the mounting plate through the holes designated to go into
drywall and reattach the toggle wings onto each bolt.
3. Place the mounting plate against the wall and insert the toggle wings into the
holes in the wall to mount the plate.
4. Push the mounting plate flush against the wall. Make sure the tabs on the
mounting plate touch the bottom of the cabinet or the horizontal line if
mounting under a cabinet with a front overhang, and that the plate is properly
centered under the cabinet.
NOTE: Avoid pinching fingers between the back of the mounting plate and the
wall.
d
e
a
b
18
f
c
a
Blower Plate
b
Back of Microwave
b
a
b
c
d
e
f
Mounting Plate
Wall
Bolt End
Spacing for Toggles
More Than Wall
Thickness
Toggle Wings
Toggle Bolt
Tabla de contenido
loading

Este manual también es adecuado para:

Hmv1652

Tabla de contenido