Condensation protection (only available on installations with cooling radiant control). Enables to select the
protection level against condensation: Very high, high, medium (by default), low and very low. If necessary, it can be
activated for 1h.
•
Battery temperature. Allows to set the working limit temperatures of the cooling and heating batteries of the fancoil
module ((AZDI6ZMOFAN [C/R]), provided that they are installed.
-
Heating battery: To set the mínimum temperature for the water of the heating battery. (Default preset 37 ˚C)
-
Cooling battery: To set the maximum temperature for the water of the cooling battery. (Default preset 17 ˚C)
•
Dehumidifier function (only available in installations with fancoil zone module AZDI6ZMOFAN[C/R], if the
temperature probe of the cooling battery AZX6SONDPROTEC is installed). It allows the Dehumidifier function to be
enabled in the system, as well as setting the relative humidity limit that is not to be exceeded in the installation. This
function allows you to automatically switch to dry mode when the installation is working in cooling mode and the set
dehumidification conditions are reached.
•
Automatic mode (only available in installations with fancoil zone module AZDI6ZMOFAN[C/R] configured as 2 pipes in
which the temperature probe of the cooling battery AZX6SONDPROTEC is installed). It allows the Automatic mode
function to be activated, thanks to which the system manages the change between cooling/heating mode
autonomously. With the automatic mode activated, the option of changing the mode manually from the thermostat
is disabled.
•
Reset system (only available for master thermostat Blueface). Resets the system and returns to factory settings. To
reconfigure the thermostats, please check Initial setup).
Think
•
Information. It provides information about the zone, the system, the devices and the Webserver.
•
Radio channel. It activates/deactivates the Wireless association module of the system.
ZONE SETTINGS
Important: In Think thermostats, press
•
Zone address (only available from remote zones, in zones controlled by Lite thermostats). Shows and allows to modify
the zone number assigned among the availables.
•
Associated outputs. It displays and allows you to select the control outputs associated with the thermostat.
•
Thermostat settings (only available in thermostats Blueface). Use this parameter to define the thermostat as Master or
Zone.
*Note: It cannot be configured as Master if there is already another Master thermostat (except for 4-pipe installations).
•
Use mode. The thermostats can be set in Basic or Advanced mode. They are set in Advanced mode by default. These
are the parameters you can control in basic mode: On/off, set-point temperature, fan speed and operation mode (only
available for zone thermostats in installations configured as four-pipe).
If you need to reset the thermostat to Advanced mode, access the advanced configuration menu and then activate
the advanced use mode.
•
Control stages (only available in installations with AZDI6OUTPUT8 modules). This parameter is used to configure both
cooling and heating stages in a single zone or in all the zones. These are the features to be configured:
-
Air: Enables air heating/cooling in the selected zone and allows the user to select the type of production available
in the zone (direct expansion or water unit).
-
Radiant: It activates radiant heating/cooling.
-
Combined: It activates both air and radiant heating/cooling in the zone selected and also allows the user to select
the desired heating stage: Air, Radiant or Combined. The zone will start using the heating air stage and once the
to confirm and
to return to the previous menu/screen.