System consumption

Displays information about the amount of time of demand of the zone and about the operation of the system during the day.

Zone settings

From this menu you can act on:
ES
Sleep Mode. The Sleep mode works as an auto power-off Eco-timer of the zone. These are the values you can select:
Off. The timing is off.
EN
30. It activates the timing and switches off the zone after 30 minutes.
FR
60. It activates the timing. After 30 minutes, the zone varies one degree its temperature. After 60 minutes, the zone
will switch off.
90. It activates the timing. After 30 minutes, the zone varies one degree its temperature. After 60 minutes, the zone
IT
varies another degree the temperature. Finally, after 90 minutes, the zone will switch off.
Anti-freezing. It prevents the room temperature from dropping below 12ºC, although the zone is off. (It will not activate in
PT
Stop mode).
DE
Lite settings. You can use this parameter to define base set-point temperature for zones with Airzone Lite. Besides, you can
also configure your wired Airzone Lite cable to act as wireless (the LED light will switch off after a few seconds).