Faema Emblema A4 Manual Del Usuario página 56

Tabla de contenido
English
5.
Manual control panel
Move the cursor to the "manual" line with the "+" (30) and "-" (31)
keys to access the manuals control panel.
# TECHNICAL PROG.
TESTING
A successive pressure of "PRG" key (29), visualizes on display the following panel:
G R 1
G R 2
0 0 0
0 0 0
-
Press "+" (30) or "-" (31) to display the various components.
-
Press "PRG" (29) to select the component to activate and to switch to the next panel M2.
-
Press "RES" (24) to quit manual mode.
G R 1
G R 2
0 0 0
0 0 0
-
Press "+" (30) or "-" (31) to activate the components;
if they have a direction, use "+" (30) and "-" (31) to alternate the activations (+Lh/-Rh).
-
Press "RES" (24) to return to panel M1.
1. GR..
Volumetric meter, displays incremental count, zeroed on
entry of M1 menu
2. xxx
defines the moving part that can be accessed.
+
u
Panel 1
G R 3
0 0 0
Panel 2
G R 3
0 0 0
Legend
168
MANUAL CONTROLS – permit parts to be manually operated using
the "+" and "-" keys.
Press the "PRG" key (29) key, the following message appears on the
display:
# TESTING
MANUAL COMMANDS
±
P R G
! ! ! ! !
! ! ! ! !
R E S
±
! ! ! ! !
! ! ! ! !
Here is the table of symbols used to define the moving parts
that can be accessed:
MP
Pump motor
G1÷G4
Coffee dispensing solenoid valvev
Eac
Hot water solenoid valve
Evc
Boiler load solenoid valve
Ets
Steam solenoid valve (Turbosteam)
M C
Turbosteam compressor motor
Eds
EDS solenoid valve
Em
Milk solenoid valve
English
+
u
M P : R E S