7. INSTALLATION

7.1 Inspections on arrival

Upon receipt of the unit it is essential to check that you have received all the material indicated on the accompanying document, and also that it has not been damaged
during transport. If so, have the dispatcher ascertain the extent of the damage suffered, alerting our customer management office in the meantime. Only by acting in
this way and in a timely manner will it be possible to have the missing material or compensation for damages.

7.1.1 Packing and storing

The indoor units are positioned on a wood pallet and protected with cartons (4
angulars and 1 on the top) and wrapped with a plastic film.
The unit is fixed to the pallet with 4 metal brackets (refer to "fig. 7 - How to remove
fixing brackets").
The indoor units must be handled with a forklift truck.
The storage temperature must be between -25°C and 55°C.
NOTE
Do not dispose of the packaging in the environment.
Do not dispose of, leave or leave within the reach of children the packaging
material as it may be a potential source of danger.
Once the place in which the unit is to be installed has been chosen (see the rela-
tive sections) proceed as follows to unpack the indoor unit.
Installation requirements
• At delivery, the unit must be checked and any damage must be reported im-
mediately to the carrier claims agent.
• Check if all indoor unit accessories are enclosed.
• Bring the unit as close as possible to the final installation position in its original
package in order to prevent damage during transport.

7.1.2 Selecting the installation site and minimum operating area for indoor unit

WARNING
There is flammable refrigerant in the unit and it should be installed in a well-ventilated site. If the unit is installed
inside, an additional refrigerant detection device and ventilation equipment must be added in accordance with the
standard EN378. Be sure to adopt adequate measures to prevent the unit from being used as a shelter by small
animals.
Small animals making contact with electrical parts can cause malfunction, smoke or fire. Please instruct the custo-
mer to keep the area around the unit clean.
The equipment is not intended for use in a potentially explosive atmosphere.
90
EN
Cod. 3541V991 - Rev. 00 - 09/2021
OMNIA ST 3.2
fig. 6 - Packaged internal unit
A
B
fig. 7 - How to remove fixing brackets