OMNIA ST 3.2
Menu
Menu
Menu
Level 1
Level 2
Level 3
Enable Y/N
Silent Level 1-2
Timer 1 Start
Timer 1 End
Silent Mode
Timer 1 On/Off
Timer 2 Start
Timer 2 End
Timer 2 On/Off
Enabled Y/N
Dhw Mode On/
Options
Off
Disinfect On/
Holiday
Off
Heat Mode On/
Off
From Date
Until Date
Bckp Heat On/
Backup Heater
Off
Error List
Error Code
Main Set Temp
Main
Actual
Temp
Tank Set Temp
Parameters
Service
Tank
Actual
I n f o r m a -
Temp T5
tions
Smart
Grid
Run Time Info
Time
Date
Language
Display
Backlight
Smart
Grid
Run Time Set
Online Units N°
Operate Mode
Sv1 State
Sv2 State
Sv3 State
Pump_I
Pump_O
Pump_C
Pump_S
Pump_D
Pipe Bckp He
Tank Bckp He
Gas Boiler
T1 Leav W
Temp
Water Flow
Heat Pump Cap
Power Consum.
T5 W. Tank
Tw2 Cir2 W.
Operation
Temp.
Parameter
T1S1 Cir1 Cli
Temp
T1S2 Cir2 Cli
Temp
Tw_O Plate Out
Temp.
Tw_I Plate Inl
Temp.
Tbt1 Buf Tank
Up Temp.
Tbt12 Buf Tank
Low Temp.
Tsolar
Idu Sw
Odu Model
Compr Current
Compr Freq
Compr
Run
Time
Menu
Menu
Level 4
Level 5
yes/no
enables the silent mode
to setup the silent level
you can set the start time of timer 1
you can set the stop time of timer 1
enables or not the timer 1
you can set the start time of timer 2
you can set the stop time of timer 2
enables or not the timer 2
enables holyday mode
to setup if DHW is On/Off during the holiday
to setup if disinfect function is On/Off during the holiday
to setup if heat mode is On/Off during the holiday
first day of holiday
last day of holiday
Activate / deactivate backup electrical heater (1=ON - 2=OFF)
Code
error code with date and time of the event
Date
event date
Hh.Mm
event time
temp set point for plant as a function of the selected mode
Water flow temperature (TW_OUT)
DHW boiler setpoint (T5s)
DHW boiler actual temperature (T5)
total daily operating time of the smart grid
to set time
to set the date
to set the language
on/off
to set the activation of the backlight
Working time set for SMART GRID
UNIT ONLINE INFO
Operating mode (Heat or Cool or Off)
on/off
State of the 3-way valve SV1 (plant=off, DHW=on)
State of the 3-way valve SV2 (off=cool, on=heat)
State of the 3-way valve of zone 2 (mixing valve)
State of the water pump of the unit
State of the water pump of zone 1
State of the water pumpe zone 2
State of the solar water pump
State of the DHW recirculation pump
State of the backup heater IBH1
State of the DHW boiler el. heater TBH
State of the gas boiler
Water temperature measured by probe T1
Water flow rate (estimated)
Heat pump capacity (estimated)
Measured power consumption (estimated)
Water temperature measured by probe T5
Water temperature measured by probe Tw2
Water setpoint calculated by climatic curve for zone 1
Water setpoint calculated by climatic curve for zone 2
Water temperature measured by probe Tw_out
Water temperature measured by probe Tw_in
Water temperature measured by probe Tbt1
not used
Water temperature measured by probe Tsolar
IDU Software
ODU model
Compressor input current
Compressor working frequency
Working time from the last start of the compressor
Cod. 3541V991 - Rev. 00 - 09/2021
Lower
Description
limit
YES
00.00
00.00
00.00
00.00
YES
01.01.2000 31.12.3000
01.01.2000 31.12.3000
00.00
01.01.2000 31.12.3000
Upper
Resolu-
Unit of
Default
limit
tion
measure
value
NO
/
/
0
2
1
/
23.59
1 min
hh:mm
00.00
23.59
1 min
hh:mm
00.00
ON
OFF
/
/
OFF
23.59
1 min
hh:mm
00.00
23.59
1 min
hh:mm
00.00
ON
OFF
/
/
OFF
NO
/
/
ON
OFF
/
/
ON
OFF
/
/
ON
OFF
/
/
/
01.01.2021
dd:mm:yyyy
/
01.01.2021
dd:mm:yyyy
ON
OFF
/
/
OFF
/
/
/
/
/
/
/
/
/
/
/
/
12 cooling /
5
65
1
°C
40 heating
/
/
1
°C
30
60
1
°C
/
/
1
°C
0
24
1
hh
23.59
1 min
hh:mm
00.00
/
01.01.2021
dd:mm:yyyy
/
/
/
/
English
ON
OFF
/
/
0
24
1
hh
/
/
/
/
0
3
1
/
ON
OFF
/
/
ON
OFF
/
/
ON
OFF
/
/
ON
OFF
/
/
ON
OFF
/
/
ON
OFF
/
/
ON
OFF
/
/
ON
OFF
/
/
ON
OFF
/
/
ON
OFF
/
/
ON
OFF
/
/
/
/
1
°C
/
/
0,001
m3/h
/
/
0,1
kW
/
/
1
kWh
/
/
1
°C
/
/
1
°C
/
/
1
°C
/
/
1
°C
/
/
1
°C
/
/
1
°C
/
/
1
°C
/
/
°C
/
/
1
°C
/
/
/
/
/
/
/
/
/
/
1
A
/
/
1
Hz
/
/
1
min
111
EN
NO
0
NO
ON
ON
ON
/
/
/
/
50
/
/
ON
2
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/