14. Glossary
R
Expert Mode: Supporting messages are displayed on
the screen for each individual action step.
R
Combo filter: Filter and dryer cartridge for removing
fine particles and moisture from the refrigerant.
R
PS2 stick:
Storage medium with PS2 connection; used in order
to perform software update of ACS 810, or to store
data from the internal memory of ACS 810 for data
management on a PC.
R
Recovery phase:
The refrigerant is removed from the vehicle air con-
ditioner using suction, cleaned and routed into the
internal vessel of the ACS 810. The refrigerant oil
collected in the process is drained into the used oil
bottle at the ACS 810.
R
Vacuum phase:
A vacuum is generated in the vehicle air conditioning
system. Measurement of the drop in pressure com-
mences as soon as the vacuum has been generated.
R
Fresh oil refill phase:
Fresh oil is added to the vehicle air conditioner.
R
Filling phase:
A certain quantity of refrigerant is added to the ve-
hicle air conditioner.
Robert Bosch GmbH
Glossary | ACS 810 | 65
15. Technical data
15.1
ACS 810
Property
Dimensions H x W x D
Weight
Operating voltage
Frequency
Workplace emission sound pressure level
as per EN ISO 11204
Refrigerant
Low-pressure gauge
High-pressure gauge
Capacity of internal refrigerant cylinder
Safety class
Power output
15.2
Ambient temperature
Property
Storage and transport
Operation
15.3
Air humidity
Property
Storage and transport
Operation
15.4
Electromagnetic compatibility
This product complies with the standards EN 61000-3-2
and EN 61000-3-3.
en
Value/range
1270 x 690 x 660 mm
120 kg
230 VAC ± 10 %
50 Hz
< 70 dB(A)
R134a
-1 bar – 16 bar ± 1 %
-1 bar – 40 bar ± 1%
40 l
IP 20
1300 W
Value/range
-25 °C – 60 °C
-13 °F – 140 °F
10 °C – 45 °C
50 °F – 113 °F
Value/range
<75 %
<90 %
|
S P00 D00 006
2019-02-26