en
42 | ACS 810 | Product description
4.4
Description of unit
4.4.1
Front view
5
4
3
2
1
Fig. 1:
Front view
1 Valve high pressure (HP)
2 Valve low pressure (LP)
3 Printer
4 Display and control panel
5 Gage low-pressure pressure (LP)
6 Gage high-pressure valve (HP)
7 Pressure gage of internal refrigerant cylinder
8 Fresh oil bottle
9 Used oil bottle
10 Front wheels with locking brake
i
The high (6) and low pressure (5) gages show the
current pressure during the air conditioning service
on the vehicle. The small gage (7) is used to check the
bottle pressure in the internal refrigerant cylinder.
i
The two valve settings are labeled as follows:
$
C (closed) = valve is closed
$
O (open) = valve is open
|
S P00 D00 006
2019-02-26
6
4.4.2
Rear
7
6
7
8
9
Fig. 2:
Rear
10
1 Service quick-release coupling (LP)
2 Service quick-release coupling (HP)
3 Service hose (5 m)
4 Service hose mount
5 Rear wheels
6 Power cord (socket)
7 Master switch
4
1
2
3
4
5
Robert Bosch GmbH