6. Wrap thread tape (not included) around the
threads of a 1-1/4 in. male PVC adapter (not
included). Thread the adapter into the 1-1/4 in.
opening in the front of pump (A).
7. An optional 1-1/4 in. union (not included)
is recommended for easy connection and
disconnection.
8. Using 2-step PVC system, attach 1-1/4 in.
PVC pipe and couplings as needed to connect
the 1-1/4 in. male PVC adapter to the 1-1/4 in.
PVC elbow attached to the top of the well pipe
in Step 5.
NOTE: Be sure the pipe slopes downward slightly
from pump (A) to the well to prevent air pockets.
6
1-1/4 in. Male
PVC adapter
7
1-1/4 in. Union
8
1-1/4 in. PVC Pipe
8
A
A
A
Well