PUMP ELECTRICAL CONNECTIONS
WARNING:
Always disconnect pump from electricity before performing any work on the motor.
Under-sized wiring can cause motor failure and even fire. Use proper wire size specified in the
Wire Size Chart.
Replace damaged or worn wiring cord immediately.
Do not kink power cable and never allow the cable to come in contact with oil, grease, hot
surfaces, or chemicals.
The pump must be properly grounded using the proper wire cable with ground.
CAUTION:
Protect the power cable from coming in contact with sharp objects.
All wiring should be performed by a qualified electrician in accordance with the National Electric
Code and local electric codes.
Connect the pump to a separate electrical circuit with a dedicated circuit breaker. Refer to the
Wire Size Chart for proper fuse size.
Wiring the pressure switch
CAUTION: Make certain that the power source
matches the pump requirements. This pump has
a dual voltage motor and can run on either 115 V
or 230 V.
Pump is pre-set at the factory to run on 115 V.
1. To change voltage:
a. Pump MUST be disconnected from the
power source.
b. Pull selector plug out approximately 1/4-in.
c. Rotate plug to align arrow to 115 V or 230 V
as desired.
d. Push plug back in approximately 1/4-in.
WIRE SIZE CHART
Distance from Motor to Meter
0-50 Ft.
50-100 Ft.
100-150 Ft.
150-200 Ft.
200-300 Ft.
Fuse Size (Amps)
(*)
Not economical to run in 115 V, use 230 V
Recommended Copper
Wire and Fuse Sizes
Single Phase Motors
1/2 HP
115 Volt
14
12
10
8
*
15
1
Voltage selector
13
230 Volt
14
14
14
14
12
15
Ungrounded
line
Ground
Voltage
selector
IL1957