WARNING
!
Make sure that the power source
has been turned off and that the
power cable has been unplugged
at the wall receptacle before pro-
ceeding.
B.
PT-21AMX Torch
1. Remove shrink wrap or electrical tape from lead end of torch handle (if any).
2. Remove lock ring and slide up on torch lead.
3. Holding torch body steady, unscrew handle from torch body and slide back onto
the braided shield cable assembly to expose torch connections.
4. Unscrew the power cable fitting from the torch power lead connector using a
11.2mm (0.44") open end wrench.
5. Unscrew pilot arc connector using a "J" wrench.
6. Remove torch body and reverse procedure.
Note: Tighten handle on torch body hand tight.
Note: Tighten lock ring on handle with pliers.