6.2

Overheating protection

A thermal overload cutout protects against overheating. The cutout resets automatically
when the unit has cooled.
6.3

Inductance connection

Higher inductance produces a more flowing weld and fewer spatters. Lower inductance
produces a harsher sound and a stable, concentrated arc.
7

MAINTENANCE

Regular maintenance is important for safe, reliable operation.
Note!
All guarantee undertakings from the supplier cease to apply if the customer himself attempts any work
in the product during the guarantee period in order to rectify any faults.
7.1

Inspection and cleaning

Check regularly that the power source is free from dirt.
The power source should be regularly blown clean using dry compressed air at reduced
pressure. More frequently in dirty environments. Otherwise the air inlet/outlet may be-
come blocked and cause overheating. To avoid this you can use an airfilter. The airfilter
is an accessory. Ordering number can be found on page 37.