GB
Check that the unit is connected to the correct mains power supply voltage, and that
it is protected by the correct fuse size. A protective earth connection must be made,
in accordance with regulations.
Recommended fuse sizes and minimum cable areas
TM
Origo
Mig 320
Voltage V
Current A
at100% duty cycle
at 60% duty cycle
at 30% duty cycle
Cable area mm
2 2 2 2
Fuse, slow A
NB: The mains cable areas and fuse sizes as shown above are in accordance with Swedish
regulations. They may not be applicable in other countries: make sure that the cable area and fuse
sizes comply with the relevant national regulations.
320e
Rating plate with supply connection data
3∼ 50 Hz
3∼ 50/60 Hz
230
400/415
16
9
23
14
35
20
4 x 4
4 x 2,5
20
16
- - 9 - -
3∼ 50 Hz
3∼ 60 Hz
500
230
7
16
10
23
16
34
4 x 2,5
4 x 4
16
20
3∼ 60 Hz
440/460
8
12
18
4 x 2,5
16