GB
5.4
Assembly of stabilizer
Assemble the stabilizer if counter balance is to be installed on machine. The stabilizer
is an accessory. Ordering number you can find on page 37.
Attention! Utilization of counter balance without stabilizer may cause the machine
tipping over.
6
OPERATION
General safety regulations for the handling of the equipment can be found on
page 4. Read through before you start using the equipment!
WARNING - - TIPPING RISK!
There is a risk of tipping while transportation and operation, if the welding machine leans
o
more than 10
. In that case appropriate securing has to be provided !
6.1
Connection and control devices
1
Mains supply switch
2
Switch, precise control
3
Switch, coarse control
4
Indicating lamp, power supply ON
5
Orange indicating lamp, overheating
6
Digital meter
320e
7
Connection for return cable (--), high induc-
tance
8
Connection for return cable (--), low induc-
tance
9
Connection for welding current cable (+)
10
Connection for control cable for wire feeder
11
MCB
- - 10 - -