Troubleshooting; Automatic Filter Cleaning Cannot Be Switched Off; Disposal - Würth ISS 45-M automatic Traducción Del Manual De Instrucciones De Servicio Original

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 49

Troubleshooting

DANGER
First pull out the plug from the mains be-
fore carrying out any tasks on the ma-
chine.
Note: In case of a failure (e.g. filter breakage) the
appliance must be turned off immediately. The fail-
ure must be remedied before the appliance is put
into operation again.
Suction turbine does not run
 Check the receptacle and the fuse of the pow-
er supply.
 Check the power cable, the power plug, the
electrodes and the receptacle of the device.
 Turn on the appliance.
Suction turbine turns off
 Empty the container.
Suction turbine does not start again
after the container has been
emptied
 Turn off the appliance and wait for 5 seconds,
turn it on again after 5 seconds.
 Clean the electrodes as well as the space be-
tween the electrodes with a brush.
Suction capacity decreases
 Remove blockages in the suction nozzle, suc-
tion tube, suction hose, or flat pleated filter.
 Replacing the full fleece filter bag.
 Replace the filled disposal bag (option).
 Ensure the filter cover properly locks into
place.
 Clean or replace the membrane filter (special
accessory) under running water.
 Replace the flat pleated filter.
Dust comes out while vacuuming
Illustration
 Check/correct the correct positioning of the
flat fold filter.
 Replace the flat pleated filter.
24
Automatic shut-off (wet vacuum
cleaning) does not react
 Clean the electrodes as well as the space be-
tween the electrodes with a brush.
 Continuously check the filling level in case of
non-conductive liquid.
Horn sounds
 Set the rotary switch to the correct suction hose
cross-section.
 If the fleece filter bag is full and the minimum
volume flow is fallen short of it has to be re-
placed.
 If the disposal bag (option) is full and the min-
imum volume flow is not achieved, this filter
has to be replaced.
Automatic filter cleaning is not
working
 Suction hose is not connected.
Automatic filter cleaning cannot be
switched off
 Inform Customer Service
Automatic filter cleaning cannot be
switched on
 Inform Customer Service
Customer Service
If malfunction can not be fixed, the de-
vice must be checked by customer ser-
vice.

Disposal

At the end of its lifetime the appliance is to be dis-
posed of according to the statutory provisions.
GB - 8
Tabla de contenido
loading

Tabla de contenido