Maintenance And Care; Troubleshooting - Würth MASTER TSS 12 Traducción Del Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27

Maintenance and care

Danger
First pull out the plug from the mains be-
fore carrying out any tasks on the ma-
chine.
Caution
Keep the device and the ventilation lou-
vres clean in order to be able to work
well and safely.
If the vacuum cleaner should fail inspite of thor-
ough manufacturing and testing procedures,
have the repair performed by a Würth master-
Service centre.
Please indicate the part number taken from the
type plate of the vacuum cleaner in case of
questions or spare parts orders.
Clean main filter basket
 Main filter basket (washable), clean it under
running water if necessary.
Caution
Risk of damage! Never insert the main
filter basket while wet.
Replace exhaust filter
Exhaust filter: Change once a year
 Release and remove the cover.
 Remove the filter casing.
 Remove the exhaust filter from the filter hous-
ing.
 Insert new exhaust filter into filter housing.
 Insert filter casing.
 Install and lock the cover.
Replace motor protection filter
Replace the motor protection filter every
three months for daily use; replace as
needed if severely contaminated.
 Release and remove the suction head.
 Push the grids of the motor protection filter
down, turn and remove.
 Remove the motor protection filter.
12
 Insert the new motor protection filter.
 Insert the grid of the motor protection filter and
lock it into place.
 Insert and lock the suction head.

Troubleshooting

Danger
First pull out the plug from the mains be-
fore carrying out any tasks on the ma-
chine.
The appliance shuts off during the
operation
Motor thermal protector has responded.
 Replace the fleece filter bag or paper filter
bag (option).
 Replace motor protection filter.
 Replace exhaust filter.
 Check all parts for plugging.
Switching back on after the motor turbine has
cooled off, after approx. 30 to 40 minutes.
Suction turbine does not run
 Check cables, plugs and socket.
 Turn on the appliance.
Suction capacity decreases
 Remove choking of suction nozzle, suction
tube or suction hose.
 Replace the fleece filter bag or paper filter
bag (option).
 Clean the main filter under running water.
 Insert/lock the suction basket correctly.
 Replace defective suction hose.
 Replace motor protection filter.
3
Tabla de contenido
loading

Este manual también es adecuado para:

0701 112 0

Tabla de contenido