9-5
Technical Specifications
Electrical Ratings
Note:
Drive
Power
(kW/hp)
peak/rms for 10ms (A)
0.25/0.3
0.37/0.5
0.55/0.75
0.75/1.0
Drive
Power
(kW/hp)
peak/rms for 10ms (A)
1.1/1.5
1.5/2.0
Drive
Power
(kW/hp)
0.37/0.5
0.55/0.75
0.75/1.0
1.1/1.5
1.5/2.0
2.2/3.0
Drive
Power
(kW/hp)
*
2.2/3.0
Drive
Power
(kW/hp)
*
2.2/3.0
3.0/4
4.0/5
Drive
Power
(kW/hp)
3.0/4
4.0/5
5.5/7.5
7.5/10
* The Frame 3, 2.2kW drive is capable of operating on a 1-phase or 3-phase supply.
650 Series AC Drive
Motor power, output current and input current must not be exceeded under steady state
operating conditions.
Maximum Motor dv/dt = 10,000V/s. This can be reduced by adding a motor choke in series
with the motor. Contact Parker for recommended choke details.
Local wiring regulations always take precedence. Select cable rated for the drive.
The supply must be protected with a fuse (or Type B RCD) rated to the supply cable.
For 3-phase units Frames 2 & 3, the Surge Current is less than the running current.
FRAME 1 : 1-Phase (IT/TN), 230V
Input Current @ 5kA
Surge Current
19/12
19/12
20/14
22/15
FRAME 2 : 1-Phase (IT/TN), 230V
Input Current @ 5kA
Surge Current
24/17
25/18
FRAME 2 : 3-Phase (IT/TN), 400V
Input Current @ 10kA
(A)
2.5
3.3
4.1
5.9
7.5
9.4
FRAME 3 : 1-Phase (IT/TN), 230V
Input Current @ 7.5kA
(A)
22.0
FRAME 3 : 3-Phase (IT/TN), 230V
Input Current @ 7.5kA
(A)
14.3
18.1
23.1
FRAME 3 : 3-Phase (IT/TN), 400V
Input Current @ 10kA
(A)
11.1
13.9
18.0
23.6
Output Current @ 40
(A) ac
(A)
4.2
1.5
6.2
2.2
7.9
3.0
10.5
4.0
Output Current @ 40
(A) ac
(A)
13.8
5.5
16.0
7.0
Output Current @ 40
(A) ac
1.5
2.0
2.5
3.5
4.5
5.5
Output Current @ 40
(A) ac
9.6
Output Current @ 40
(A) ac
9.6
12.3
16.4
Output Current @ 40
(A) ac
6.8
9.0
12.0
16.0
o
C
Maximum Power
Loss
(W)
26
32
41
52
o
C
Maximum Power
Loss
(W)
65
82
o
C
Maximum Power
Loss
(W)
26
32
40
55
61
70
o
C
Maximum Power
Loss
(W)
112
o
C
Maximum Power
Loss
(W)
103
133
180
o
C
Maximum Power
Loss
(W)
80
100
136
180