MMI Parameters Table
Display
Parameter
PID ERROR
F
PID OUTPUT
F
DIN 1 INVERT
DIN 2 INVERT
DIN 3 INVERT
DIN 4 INVERT
AIN 1 SCALE
AIN 1 OFFSET
AIN 1 TYPE
AIN 2 SCALE
AIN 2 OFFSET
AIN 2 TYPE
DIN 1 VALUE
F
DIN 2 VALUE
F
DIN 3 VALUE
F
DIN 4 VALUE
F
AIN 1 VALUE
F
AIN 2 VALUE
F
AOUT 1 SOURCE
AOUT 1 SCALE
AOUT 1 OFFSET
AOUT 1
ABSOLUTE
AOUT 1 VALUE
F
650 Series AC Drive
Description
The result of SETPOINT - FEEDBACK x FEEDBACK
GAIN
The output of the PID function block
SET::IN Menu
Inverts the value of the signal, TRUE or FALSE.
As
S
IP01
As
S
IP01
As
S
IP01
TYPE
SCALE
X
UNPROCESSED
INPUT
0 to 100% of selected TYPE
TYPE
SCALE
X
UNPROCESSED
INPUT
0 to 100% of selected TYPE
The TRUE or FALSE input (after any inversion)
The TRUE or FALSE input (after any inversion)
The TRUE or FALSE input (after any inversion)
The TRUE or FALSE input (after any inversion)
The input reading with scaling and offset applied
The input reading with scaling and offset applied
SET::OUT Menu
ANALOG OUTPUT
0 NONE
SCALE
1 DEMAND %
OFFSET
2 CURRENT %
3 PI ERROR %
ABSOLUTE
4 RAISE/LOWER %
OUTPUT
SCALE
OFFSET
+
X
VALUE
Programming Your Application
Range
—.xx %
—
0= FALSE
1= TRUE
As
As
As
-300.0 to 300.0%
OFFSET
-300.0 to 300.0%
+
VALUE
0= 0-10V
1= 0-5V
-300.0 to 300.0%
OFFSET
-300.0 to 300.0%
+
0= 0-10V
VALUE
1= 0-5V
2= 0-20mA
3= 4-20mA
0=FALSE
1=TRUE
0=FALSE
1=TRUE
0=FALSE
1=TRUE
0=FALSE
1=TRUE
.x%
.x%
0= NONE
1= DEMAND
2= CURRENT
0-10V
3= PID ERROR
4= RAISE/LOWER
-300.00 to 300.00%
ABS
-300.00 to 300.00%
X
0= FALSE
100%
1= TRUE (absolute)
CLAMP
OUTPUT
-300.0 to 300.0%
0%
6-4
Default
—.xx%
—
.xx %
.xx %
0
S
IP01
0
S
IP01
0
S
IP01
0
100.0%
0.0%
0
100.0%
0.0%
3
-
-
-
-
—
.x%
—
.x%
1
OUTPUT
100.00%
0.00%
1
(not absolute)
0.0%