9. TROUBLESHOOTING
Problem
The machine does not turn on.
The tap leaks.
Product leaks from the rear part of the bowl.
The auger does not turn
The machine does not make granita.
The auger is noisy.
The tap does not dispense
If the machine malfunctions due to causes other than those listed in this table or the proposed remedies do not solve the problem, contact a specia-
lized technician.
- 20 _EN -
Cause
The main switch is off (positioned on "O"). (Chap.6)
The machine is not plugged in.
The tap plug is not lubricated. (Fig.41)
The plug is defective.
The bowl seal is not lubricated. (Fig.37)
The seal is defective.
The switch is positioned on "O". (Chap.6)
Blocks of ice inside the bowl.
The switch is positioned on "O". (Chap.6)
The machine is near sources of heat.
The condenser is dirty. (Chap.7.8)
The consistency has not been adjusted correctly.
(Chap.6.6)
Timer levers in position "
".
The front seal has been applied incorrectly. (Fig.35)
The seal is not lubricated. (Fig.36)
Blocks of ice inside the bowl.
Press the switch into position "I".
Insert the plug in a suitable outlet.
Lubricate the plug.
Replace the plug.
Check the positioning of the bowl.
Chap.7.5)
Lubricate accordingly.
Replace the seal.
Press the switch into position "I".
Switch off the machine, allow the bowl contents to melt
and check that the product has been correctly diluted.
Press the switch into position "I".
Install the machine in a suitable place (Chap.5).
Call in a specialized technician to clean the
condenser.
Correctly adjust the consistency.
Place the levers in position "
Check that the seal is applied correctly.
Lubricate the seal accordingly.
Switch off the machine, allow the bowl contents to melt
and check that the product has been correctly diluted.
Remedy y
" see sect. 6.8.
SL310006542 Ed.02 - 07-2017